Фрагмент инструкции


WARNING: This is an unvented gas- fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air For Combustion and Ventilation section on page 4 of this manual. Do not store, or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or gas supplier. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or gas supplier. This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion.An unvented room heater productes approximately one (1) ounce (30ml) of water for every 1,000 BTU’s (.3KW’s) of gas input per hour. Refer to page 3. *Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. Continental Appliance Inc. 5 Musick 4600 Highlands Irvine Parkway S.E. Suite# D/E CA 92618 Smyrna GA 30080 Installer: Please leave these instructions with the consumer. Consumer: Please retain these instructions for future use. TOLL-FREE NUMBER: 1-877-886-5989 IMPORTANT SAFETY INFORMATION WARNINGS IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. WARNING: Do not use any accessory not approved for use with this heater. WARNING: Any change to this heater or its controls can be dangerous. Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater. Due to high temperatures, heater should be kept out of traffic and away from furniture and draperies. Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut down. Allow surface to cool before touching. Carefully supervise young children when they are in the same room with heater. Make sure grill guard is in place before running the heater. Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts. Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit. In the state of Massachusetts, unvented propane or nature gas-fired space heaters shall be prohibited in bedrooms and bathrooms. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outside. 3. If you smell gas . Shut off gas supply. . Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. . Immediately call your gas sup plier from a neighbor’s phone. Follow the gas supplier’s instructions. . If you cannot reach your gas supplier, call the fire department. 4. Always run heater with control knob at LOW or HIGH locked positions. Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result. 5. This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensor (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Fresh Air for Combustion and Ventilation pages 4 and 5. 6. Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion. 7. If heater shuts off. Do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced. 8. Do not operate heater where flammable liquids or vapors are used or stored . under dusty conditions 9. Do not install models ML100HPA and ML100TPA in a bathroom. 10. Before using furniture polish, wax, c...

Эта инструкция также подходит к моделям:
Электрообогреватели - ML100HPA (1.34 mb)
Электрообогреватели - ML100TPA (1.34 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории