Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Bryant, модель 376B

Производитель: Bryant
Размер: 1.09 mb
Название файла: 40376dp5-b.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Before beginning the installation, READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY. INTRODUCTION Before installing the furnace, refer to “Procedure for Induced-Combustion Gas-Fired Furnaces” (packaged with the equipment) for information concerning combustion, venting, piping, and other standard installation practices. Further reference is made to the current edition of the National Fuel Gas Code NFPA No. 54-1984/ANSI Z223.1-1984. The induced-combustion vent system of this furnace is designed to operate at zero or negative pressure at the vent connector outlet. This furnace, therefore, complies with the National Fuel Gas Code (NFPA No. 54-1984/ANSI Z223.1-1984), Part 7.14.3.b. This furnace is also listed by A.G.A. for use with the type B1 gas vent, as described in the National Fuel Gas Code, Part 7.3.2. Each furnace is shipped from the factory completely assembled with multispeed direct-drive blower and wired ready for indoor heating installation. All sizes feature a blower control center with easy-to-read low-voltage terminal strip to ensure proper connections. The output capacity and any representations of efficiency for this product are based on standard Department of Energy test procedures. The installed operation may vary, depending on installation, weather, or other factors. TABLE I—CLEARANCES (In Inches) Sizes 040 and 055 075 thru 115 DOWNFLOW (In Alcove or Closet) Sides—Single-Wall Vent 0 Type-B1 Double-Wail Vent 0 0 Back 0 0 Top 1 Front*—Single-Wall Vent 6 6 Type-B1 Double-Wall Vent 3 ' 3 Vent—Single-Wail 6 6 Type-B1 Double Wall 1 HORIZONTAL (In Alcove) SidesT 0 Back 0 0 Top—Single-Wall Vent 1 Type-B1 Double-Wall Vent 0 0 Front* 18 18 Vent—Single-Wall 6 6 Type-B1 Double-Wail 1 1 HORIZONTAL (In Closet) Sides! 1 1 . Back 3 3 Top—Single-Wall Vent 2 2 ' Type-B1 Double-Wail Vent 2 2 Front*—Single-Wall Vent 6 6 Type-B1 Double-Wall Vent 3 3 Vent—Single-Wall 6 6 Type-B1 Double-Wall 1 1 ♦Provide a 30-in. service clearance in front of the furnace, t Indicates supply or return sides when furnace is in the horizontal position. Cancels: 39376DP5-A 40376DP5-B 9/1/85 The design of the downflow/horizontal gas-fired furnace is A.G.A. certified for natural and LP(propane) gas and for installation on combustible flooring (with optional floor base), in alcoves, attics, crawl spaces, basements, closets, or utility rooms. The design of this furnace line is not A.G.A. certified for installation in mobile homes, recreation vehicles, or outdoors. BDP Company TABLE III—RATINGS TABLE II—DIMENSIONS (In Inches) Size A D E Vent Conn 024040 1 4-3/1 6 12-9/16 12-11/16 4 024055 14-3/1 6 12-9/16 12-11/16 4 036055 14-3/1 6 12-9/16 12-11/16 4 036075 17-1/2 1 5-7/8 16 4 048075 17-1/2 1 5-7/8 16 4 048095 17-1/2 1 5-7/8 16 4 060095 21 19-3/8 19-1/2 4 060115 24-1/2 22-13/16 23 5 PERFORMANCE* SIZE Input Buth* Capacity Buthft Temperature Rise Range Heating Cooling Motor HP & Type shipping Weight


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории