Войти:
Оценок - 1, средний балл: 5 ( )

Инструкция по эксплуатации Lochinvar, модель KBN-SUB-09

Производитель: Lochinvar
Размер: 256.02 kb
Название файла: 5890cc29-efdd-47c3-b5c1-6eccadca80f4.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


CONTRACTOR_ MODEL NO._ TYPE GAS _ Btu/hr INPUT_ Btu/hr OUTPUT_ NOTES Standard Features >Energy Star® Qualified > Up to 96% DOE AFUE Efficiency > Modulating Burner with 5:1 Turndown > Direct-Spark Ignition > Low NOx Operation > Field Convertible from Natural to LP Gas > Vertical & Horizontal Direct-Vent > PVC, CPVC or SS Venting up to 100 Feet > Factory Supplied Sidewall Vent Termination > ASME Stainless Steel Heat Exchanger > Automatic Reset High Limit > Inlet & Outlet Temperature Sensors > Boiler Circulating Pump > 30 psi ASME Relief Valve > Adjustable Leveling Legs (KB Models only) > Wall Mount Bracket (WB Models only) > Zero Clearances to Combustible Material > 12 Year Limited Warranty (See Warranty for Details) SMART SYSTEM™ Features > SMART SYSTEM Digital Operating Control > 2 line, 16 Character Display > Dual Level Password Security > Domestic Hot Water Prioritization > Built in Cascading Sequencer for up to 8 Boilers > 0-10 VDC Input Control > Outdoor Reset Control with Outdoor Air Sensor > Low Water Flow Safety Control & Indication > Alarm on Any Failure Contacts > Service Reminder > Freeze Protection > Night Setback > Time Clock > Three Pump Control (System, Boiler & DHWP) > Data Logging > Examples: Hours Running, Space Heating > Programmable System Efficiency Optimizers > Examples: Anti-cycling, Ramp Delay Optional Equipment Place an X in the box by all options that apply I I Adjustable High Limit w/ Manual Reset □ Flow Switch □ Low Water Cutoff w/Manual Reset & Test Alarm Bell □ Concentric Vent Kit □ Condensate Neutralization Kit □ SMART SYSTEM PC Software Multi-Stack Frame Firing Codes □ M9 Standard Construction I IM7 California Code KNIGHT Heating Boiler and Wall Mount Dimensions & Specifications 0 KNIGHT Heating Boiler <0 Dimensions & Specifications Input Heating NET Model Min Max AFUE Capacity I=B=R Gas Water Air Vent Shipping Number MBH MBH % MBH MBH A C D E F G H I J K M Conn. Conn. Inlet Size Weight WBN050 10 50 95.3 45 39 29-1/4" 15-3/4" NA 10-3/4" 10-3/4" 2" 6-3/4" NA 3-1/4" 4-1/4" 2-3/4" 1/2" 1" 2" 2" 130 WBN080 16 80 95.3 72 63 29-1/4" 15-3/4" NA 10-3/4" 10-3/4" 2" 6-3/4" NA 3-1/4" 4-1/4" 2-3/4" 1/2" 1" 2" 2" 130 WBN105 21 105 95.4 94 82 29-1/4" 15-3/4" NA 10-3/4" 10-3/4" 3-1/2" 5-1/2" NA 3-1/4" 4-1/4" 2-3/4" 1/2" 1" 2" 2" 134 WBN150 30 150 95.5 135 119 29-1/4" 20-3/4" NA 15-3/4" 8-1/2" 3-1/2" 5-1/2" NA 8-3/4" 9-3/4" 1-1/2" 1/2" 1" 3" 3" 162 WBN210 42 210 95.7 190 165 29-1/4" 25" NA 20" 12" 3-1/2" 5-1/2" NA 13" 14" 1-1/2" 1/2" 1" 3" 3" 177 KBN080 16 80 95.3 72 63 33-1/4" 14" 7" 5-3/4" 5" 3" 20-1/2" 22" 1-3/4" 6-1/2" NA 1/2" 1" 3" 3" 125 KBN105 21 105 95.4 94 82 33-1/4" 14" 6-1/2" 5-3/4" 4-1/2" 1-1/2" 20-1/2" 22" 1-3/4" 6-1/2" NA 1/2" 1" 3" 3" 129 KBN150 30 150 95.5 135 119 33-1/4" 18" 12-1/4" 11-1/2" 10" 1-1/2" 21-1/4" 23" 1-3/4" 12" NA 1/2" 1" 3" 3" 157 KBN210 42 210 95.7 190 165 33-1/4" 22-1/4" 16-1/2" 15-3/4" 14-1/4" 5-1/4" 21-1/4" 23" 1-3/4" 16-1/4" NA 1/2" 1" 3" 3" 172 KBN285 57 285 96.0 260 226 42-1/2" 19-3/4" 12-3/4" 13-1/2" 6" 2" 34" 31" 11-3/4" 4-1/4" NA 3/4" 1-1/4" 4" 4" 224 Notes: Performance data based on manufacturer’s test results. Indoor installation only. All information subject to change. Change “N” to “L” for LP gas models. B Lochinvar ' High Efficiency Water Heaters, Boilers and Pool Heaters Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615- te s'££nfiiX® -8900 / Fax: 615-547-1000 5/09—Printed in U.S.A....


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории