Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Nordyne, модель G6RC 90+

Производитель: Nordyne
Размер: 650.41 kb
Название файла: g6rc_installation.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Airflow rates of 1800 CFM or more ** Factory Set Heating Speed 2. Temperature rises in the table are - Not Recommended 3. Temperature rises and airflows These conditions are not recommended. INSTALLATION REQUIREMENTS • NFPA-90B - Warm Air Heating and Air Conditioning Systems. Requirements and Codes This furnace must be installed in accordance with these instructions, all applicable local building codes, and the current revision of the National Fuel Gas Code (ANSI-Z223.1, NFPA-54). The current revision of the National Fuel Gas Code is available from: American National Standards Institute, Inc. 1430 Broadway New York, New York 10018 Canada installations shall comply with CAN/ CGA-B149 installation codes, local plumbing or waste water codes and other applicable codes. Additional helpful publications are: • NFPA-90A - Installation of Air Conditioning and Ventilating Systems. These publications are available from: National Fire Protection Association, Inc. Batterymarch Park Quincy, Massachusetts 02269 ! WARNING: This furnace is not approved for installation in mobile homes. Installation in a mobile home could cause fire, property damage, and/or personal injury. Model Number Furnace Btuh Dimensions (inches) Shipping Weight (lbs)A B C D G6R(C,D)040C 40,000 14 1/4 12 3/4 5 1/8 11 3/4 133 G6R(C,D)060C 60,000 14 1/4 12 3/4 5 1/8 11 3/4 140 G6R(C,D)080C 80,000 19 3/4 18 1/4 7 7/8 17 1/4 172 G6R(C,D)100C 100,000 19 3/4 18 1/4 7 7/8 17 1/4 180 G6R(C,D)120C 120,000 22 1/2 21 9 1/4 20 204 G6RL040C 40,000 14 1/4 12 3/4 4 5/8 12 3/4 135 G6RL060C 60,000 14 1/4 12 3/4 4 5/8 12 3/4 135 G6RL080C 80,000 19 3/4 18 1/4 10 18 1/4 174 G6RL100C 100,000 19 3/4 18 1/4 10 18 1/4 185 Table 3. Furnace Dimensions and Shipping Weights CLEARANCES TO COMBUSTIBLE MATERIALS This furnace is Designed Certified by AGA/CGA Laboratories for the minimum clearances to combustible material listed in Table 4. See the furnace name plate, located inside the furnace cabinet, for specific model number and clearance information. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL Furnace Input (Btuh) Cabinet Width (Inches) Minimum Clearances (Inches) Side Vent Back Top Front 40,000 14 1/4 0 0 0 1 1* 60,000 14 1/4 0 0 0 1 1* 80,000 14 1/4 0 0 0 1 1* 100,000 19 3/4 0 0 0 1 1* 120,000 22 1/2 0 0 0 1 1* * 24 inches is the minimum clearance for servicing. 36 inches is the recommended clearance for service. Table 4. Minimum Clearances to Combustible Materials Location The furnace must be installed on a level surface, and as close to the center of the air distribution system as possible. See Table 3 for overall dimensions to determine the required clearances in hallways, doorways, stairs, etc. to allow the furnace to be moved to the installation point. The furnace must be installed so that all electrical components are protected from water. Minimum clearances to combustible materials are listed in Table 4. Access for positioning and servicing must be considered when locating the unit. 24 inches is the minimum required clearance for servicing the unit. 30 inches is the minimum required clearance for positioning the unit. 36 inches is the recommended clearance from the front of the unit. Please note that a panel or door can be located such that the minimum clearance on the rating plate is satisfied, but that panel or door must be removable and allow the appropriate clearance for your installation. This furnace is certified for use on wood flooring. The furnace must be installed on a solid surface and must be level front to back and side to side. This furnace must not be installed directly on carpeting, tile, or any combustible material other than wood flooring. DOWNFLOW WARNING (G6RL Models): The design of the downflow furnace is certified for natural or propane gas and for installation on non-combustible flooring. A special combustible floor sub-base is required when installing on a combustible floor. Failure to install the subbase may result in fire, property damage and personal injury. The special downflow sub-bases are factory supplied accessories, part numbers 902677 and 902974. When the furnace is installed on a factory or site-built cased air conditioning coil, the sub-base is not necessary. However, the plenum attached to the coil casing must be installed such that its surfaces are at least 1" from combustible construction. A gas-fired furnace installed in a residential garage must be installed so that the bottom of the furnace is located a minimum of 15" from the floor. The furnace must be located or protected to avoid physical damage by vehicles. HORIZONTAL INSTALLATIONS The G6RC model furnaces are approved for horizontal installation. Installation Kit #903568 is required for horizontal applications. Follow the installation instructions in the kit for proper conversion. NOTE: The G6RD and G6RL models are NOT approved for horizontal installation. SUPPLY AIR PLENUM INSTALLATION A. Installation on a concrete slab - G6RL 1. Construct a hole in the floor per the dimensio...

Эта инструкция также подходит к моделям:
Электрообогреватели - G6RL 90+ (650.41 kb)
Электрообогреватели - G6RD 93+ (650.41 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории