Инструкция по эксплуатации Empire Comfort Systems, модель DV-55T-1

Производитель: Empire Comfort Systems
Размер: 919.65 kb
Название файла: 495c2266-d93a-482e-9980-df59d38250dc.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


10036. High Altitudes For altitudes/elevations above 2,000 feet, input ratings should be reduced at the rate of 4 percent for each 1,000 feet above sea level. Canadian High Altitudes for locations having an elevation above mean sea level between 2,000 feet (610m) and 4,500 feet (1370m), the manifold pressure is to be decreased from 4.0" w.c. to 3.2" w.c. for Natural Gas and from 10.0" w.c. to 8.0" w.c. for Propane Gas. Piezo Pilot Ignitor Instructions Depressingtheredbuttoncompletelycausesasparktooccuratthepilot.This is a substitute for a match which requires opening the pilot hole cover. To light the pilot, it is important that the electrode be 1/8" from the thermocouple. The spark must occur at the point the burner flame hits the thermocouple. The end of the electrode will be red hot with the pilot on. On a new installation with air in the gas line, it is suggested that a match be used. The match will light the pilot faster than the piezo under this condition. SPECIFICATIONS Model DV-55T Input- BTU/HR 55,000 Height 82 3/8" Width 16" Depth 11 1/2" Gas Inlet 1/2" Pipe CFM 400 Accessories SOR-1 Register, Side Outlet SOK-1 Side Outlet Kit, 10" Boot Assembly *DV-822 Vinyl Siding Vent Kit DV4T-812-1 Vent Kit (8" to 12" wall depth) DV4T-1219 Vent Kit (12" to 19" wall depth *DV-822, Vinyl vent kit, adds 3" to wall depth. You must include the three (3) additional inches for TOTAL wall depth when ordering a vent kit. Page 6 13118-7-0408 13118-7-0408 Page 7 Locating Gas Supply The gas line can enter the unit either through the floor or outside wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Note: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized. Note: Since some municipalities have additional local codes, it is always best to consult your local authority and installation code. The use of the following gas connectors is recommended: — ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing and Fittings — ANS Z21.45 Assembled Flexible Appliance Connectors of Other Than All-Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction. The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length. Figure 1 Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/ CGA-B149 (.1 or .2) installation code. Installing a New Main Gas Cock Each appliance should have its own manual gas cock. A manual main gas cock should be located in the vicinity of the unit. Where none exists, or where its size or location is not adequate, contact your local authorized installer for installation or relocation. Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases. The gas lines must be checked for leaks by the installer. This should be done with a soap solution watching for bubbles on all exposed connections, and if unexposed, a pressure test should be made. Never use an exposed flame to check for leaks. Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test. Never pressure test with appliance connected; control valve will sustain damage! A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing. It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet. This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect. Figure 2 Method of Installing a Tee Fitting Sediment Trap Pressure Testing of the Gas Supply System 1. To check the inlet pressure to the gas valve, a 1/8" (3mm) N.P.T. plugged tapping, accessible for test gauge connection, must be placed immediately upstream of the gas supply connection to the appliance. 2. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). 3. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). Attention! If one of the above procedures results in pressures in excess of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, it will result in a hazardous condition. 3/4" Recommended Gas Pipe Diameter Pipe Length (Feet) Schedule 20 Pipe Inside Diameter Tubing, Type L Outside Diameter Nat. L.P. Nat. L.P. 0-10 1//2" 12.7mm 3/8" 9.5mm 1/2" 12.7mm 3/8" 9.5mm 10-40 1/2" 12.7mm 1/2" 12.7mm 5/8" 15.9mm 1/2" 12.7mm 40-100 1/2" 12.7mm 1/2" 12.7mm 3/4" 19mm 1/2" 12.7mm 100-150 3/4" 19mm 1/2" 12.7mm 7/8" 22.2mm 3/4" 19mm GAS SUPPLY...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории