Войти:
Оценок - 4, средний балл: 4.3 ( )

Инструкция по эксплуатации Enerco, модель HS200CV

Производитель: Enerco
Размер: 609.27 kb
Название файла: b1aca3cb-7ec6-42f2-ad94-6c07559afc06.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• Propane (LP) gas odor may differ in intensity at different levels. Since Propane (LP) gas is heavier than air, there may be more odor at lower levels. • Always be sensitive to the slightest gas odor. If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussed previously. ATTENTION - CRITICAL POINTS TO REMEMBER! • Propane (LP) gas has a distinctive odor. Learn to recognize these odors. (Reference Fuel Gas Odor and Odor Fading sections above. • Even If you are not property trained in the service and repair of the heater, ALWAYS be consciously aware of the odors of propane (LP) gas and natural gas. • If you have not been properly trained in repair and service of propane (LP) gas then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on the propane (LP) gas fuel system. • A periodic sniff test around the heater or at the heater’s joints; i.e. hose, connections, etc., is a good safety practice under any conditions. If you smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY. DO NOT WAIT! Enerco Group, Inc. |Convection Construction Heater 4 Operating Instructions and Owner’s Manual CAUTION: NEVER IGNITE AND / OR RUN THIS HEATER UNLESS THE SHELLS ARE FULLY EXTENDED AND LOCKED INTO POSITION. STEP 1: HEATER AS RECEIVED OUT OF BOX.BEFORE LIFTING OUTER SHELL PROTECT HANDS. NEVER GRASP BARE METAL WITHOUT HAND PROTECTION. STEP 2: LIFT OUTER SHELL STRAIGHT UP. CARE MUST BE TAKEN TO PROTECT HANDS DURING LIFT. STEP 3: LIFT OUTER SHELL UNTIL ALL THREE CLIPS INGAGE SLOTS IN LOWER SHELL. WHEN THIS HAPPENS, THE SCREW HOLES WILL LINE UP. Make sure clip goes into slot in lower shell. 3 Places STEP 4: LOCK THE CLIP INTO PLACE WITH 3 SCREWS AS SHOWN. THE HEATER MUST NOT BE OPERATED UNLESS THE OUTER SHELL IS PROPERLY EXTENDED AND FULLY LOCKED INTO PLACE. Lock shells together and clips in place with screws in each clip. 3 Screws Total. CAUTION: NEVER IGNITE AND / OR RUN THIS HEATER UNLESS THE SHELLS ARE FULLY EXTENDED AND LOCKED INTO POSITION. Enerco Group, Inc. | Convection Construction Heater 5 Operating Instructions and Owner’s Manual OPERATING INSTRUCTIONS PREPARING FOR OPERATION 1. Extend the shell fully and lock into place as shown in the enclosed instructions sheet before lighting or operating the heater. 2. Check the heater for possible shipping damage. If any is found, immediately notify the factory. 3. Follow all of the Safety and Operating Precautions. 4. Connect the POL fitting of hose and regulator assembly to the propane cylinder by rotating the POL nut counterclockwise into the propane cylinder's valve outlet and securely tighten with a wrench. 5. Connect the hose to the heater. 6. Securely tighten all gas connections. 7. Open the cylinder's gas valve and check all gas connections with a soap and water solution. DO NOT USE A FLAME. START 1. WARNING: BEFORE LIGHTING PILOT, fully close the ball valve (turn knob fully clockwise). 2. Fully open the valve on the propane cylinder and wait 15 seconds before Step 3. 3. Depress red button on safety pilot valve admitting gas to the heater. Then push and release the ignition button until the pilot lights. 4. When the pilot lights, continue to hold the button depressed for 30 seconds, then release. 5. If pilot goes out, wait 5 minutes and repeat the lighting procedure. 6. When the pilot remains lit, open the ball valve (turn knob counter clockwise) to light main burner. Partially close valve to regulate heat output. STOP 1. Securely close valve on the propane cylinder. 2. Continue to operate heater until all fuel in the hose has burned. 3. Fully close the ball valve. RESTART AFTER SAFETY SHUTDOWN 1. Securely close valve at propane cylinder. 2. Wait 5 minutes. 3. Restart following "Start" procedure. MAINTENANCE AND STORAGE 1. The heater should be inspected before each use, and at least annually by a qualified person. 2. Before each use, check the soft "O" ring seat at the bullnose of the POL fitting. If the "O" ring is cut, scuffed, or otherwise damaged, replace it with part number 6681. 3. Turn off the gas at the LP-gas supply cylinder(s) when the heater is not in use. 4. When the heater is to be stored indoors, the connection between the LP-gas supply cylinder(s) and the heater must be disconnected and the cylinder(s) removed from the heater and stored out of doors and in accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1,Natural Gas and Propane Installation Code. SERVICING A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly: * The flame is contained within the heater. * The flame is essentially blue with perhaps some yellow tipping. * There is no strong disagreeable odor, eye burning or other physical discomfort. * There is no smoke or soot internal or external to the heater....

Эта инструкция также подходит к моделям:
Электрообогреватели - HS80CV (609.27 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории