Инструкция по эксплуатации State Industries, модель Commercial Gas Water Heater

Производитель: State Industries
Размер: 666.67 kb
Название файла: 0002917270-1.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER WARNING: If the information in these instructions are not followed exactly, a fireor explosion may result, causing propertydamage, personal injury or death. –Do not store or use gasoline or otherflammable vapors and liquids in the vicinityof this or any other appliance. –WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do notuse any phone in your building. • Immediately call your gas supplier from aneighbor's phone. Follow the gas supplier'sinstructions. • If you cannot reach your gas supplier, callthe fire department. WARNING Improper installation, adjustment, alteration, service or maintenance can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Refer to this manual for assistance or consult the local gas utilityfor further information. WARNING Flammable vapors may be drawn by air currents from other areas of the structure to this appliance. WARNING READ THE GENERAL SAFETY SECTION BEGINNING ON INSIDE COVER AND THEN –Installation and service must be performed THIS ENTIRE MANUAL BEFORE INSTALLING by a qualified installer, service agency or the OR OPERATING THIS WATER HEATER. gas supplier. Save this Manual for Future Reference. 0002917270-1 General Safety WARNING Improper installation, adjustment, alteration, service or maintenance can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Refer to this manual or consult your local gas utility for further assistance. WARNING At the time of manufacture this water heater was provided with a combination temperature-pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials, as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, and the latest edition of ANSI Z21.22 and the code requirements of ASME. If replaced, the valve must meet the requirements of local codes, but not less than a combination temperature and pressure relief valve certified as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22 by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials. The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 lbs. p.s.i.) and a discharge capacity not less than the water heater input rate as shown on the model rating plate. (Electric heaters - watts divided by 1000 x 3412 equal BTU/Hr. rate.) Your local jurisdictional authority, while mandating the use of a temperature-pressure relief valve complying with ANSI Z21.22 and ASME, may require a valve model different from the one furnished with the water heater. Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a locally prescribed temperature-pressure relief valve installed in the designated opening in the water heater in place of the factory furnished valve. For safe operation of the water heater, the relief valve must not be removed from it’s designated opening or plugged. The temperature-pressure relief valve must be installed directly into the fitting of the water heater designated for the relief valve. Position the valve downward and provide tubing so that any discharge will exit only within 6 inches above, or at any distance below the structural floor. Be certain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 30 feet, or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve. No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unless a 6. .. air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage. The Discharge Pipe: —Must not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions. —Must not be plugged or blocked. —Must be of material listed for hot water distribution. —Must be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the discharge pipe. —Must terminate at an adequate drain. —Must not have any valve between the relief valve and tank. WARNING WATER HEATERS EQUIPPED FOR ONE TYPE GAS ONLY: This water heater is equipped for one type gas only. Check the model rating plate near the gas control valve for the correct gas. DO NOT USE THIS WATER HEATER WITH ANY GAS OTHER THAN THE ONE S...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории