|
Фрагмент инструкции
OIL TUBE At regular intervals turn control valve off, let cool and clean inside control compartment. To clean cabinet, use only a damp cloth. Do not use any kind of solvent or cleaning fluid that could leave a residue or invisible coating that would burn or give off fumes when furnace is turned on. Have the furnace checked, cleaned, and repaired by a qualified service person for vent system, pilot and burner operation prior to use each year. The bearings of the fan motor should be oiled every twelve (12) months with S.A.E. 20 oil. (See Figure 10). Follow a regular service and maintenance schedule for safe and efficient operation. FIGURE 10 Examine the venting system as a routine part of the safety performance check on an annual basis. WARNING: This is a gas-fired appliance. Keep the area clear of gasoline and other flammaable vapors and liquids. All combustible material must be kept clear of this area to avoid fire or explosion. Page 13 OPTIONAL SIDE DISCHARGE KITS SIDE DISCHARGE ON CASING 1. Use Optional Kit No. 306SR-A. 2. Cut out and remove embossed area on casing side. 3. Remove knockout from inner liner. 4. Place 1-1/2” boot from kit through opening, matching flanges of boot to knockout on inner liner. 5. Mark screw holes and remove boot. 6. Drill holes with a 1/8” drill. 7. Attach inner boot with screws provided. 8. Place grille into position, drill holes into casing, and attach with screws provided. KIT NO. 306SR SIDE REGISTER - FLUSH SIDE DISCHARGE (With Extension Boot) NOTE: Maximum boot length is 10 inches. 1. Use Optional Kit No. 30SRB-A. 2. Cut opening in drywall as shown in Fig. 9. 3. Position plaster ground as shown in Figure 9. (Optional). 4. Cut out and remove embossed section on casing side. 5. Remove knockout on inner liner. 6. Put heater into position. 7. Place inner boot into position, mark and cut boot flush with wall. Place outer boot into position, mark and cut boot flush with wall. 8. Place boot trim into position, slide inner boot through wall from adjacent room and attach to inner liner. Slide outer boot through wall from adjacent room and attach to casing side. 9. Place grill in position and secure to wall. ROUGH-INS FOR SIDE DISCHARGE Install plaster grounds as shown in Figure 9. NOTE: When side discharge Kit No. 30SRB is being used, furnace should be set exactly 4” from side wall. Plaster Ground 10-3/ 16” 14-3/8” SIDE FIGURE 9 KIT NO. 30SRB SIDE REGISTER W/BOOT Page 14 14-PEK KIT INSTRUCTIONS (14’ PLUG EXTENSION KIT) FOR NON-RECESSED INSTALLATIONS ONLY 90 Degree Outside Corner 3 FT. SECTION WALL 3 FT. SECTION BOTTOM SECTION 1 2 3 4 UNITS WITH TERMINAL BOARD STEP # 1. Turn heater off following Section 3 in “Lighting Instructions” and allow to cool. 2. Turn off all electricity to heater. 3. Remove top louver assembly, fan shroud and fan blade. 4. Loosen two screws on romex connector. 5. Remove junction box cover plate. 6. Disconnect three power cord terminals and pull power cord out of top of heater. 7. Insert power cord provided in kit through romex connector and plug onto terminal board following wiring diagram found in lighting and operating instructions. 8. Tighten two screws on romex connector. 9. Replace junction box cover plate. 10. Replace fan blade, fan shroud and top louver assembly. 11. Snap 90 degree outside corner (Ref. 1) onto 3 foot section (Ref. 2) plastic raceway. Insert power cord and remove blue backing from adhesive strip on raceway and apply to side of heater. 12. Insert power cord into second 3-foot section of raceway (Ref. 3) and remove blue backing and apply to side of heater, butting up against bottom of other section. 13. Cut 14-inch long bottom section to required length (see chart), insert power cord, remove backing and apply to side of heater. 14. Plug power cord into wall receptacle. 15. Light the heater following lighting instructions. LENGTH OF BOTTOM SECTION (REF. 4) MODEL NO. PLASTIC RACEWAY DVCF40 5-5/16 Inches DVCF55 14 Inches DVCF65 14 Inches NOTE: Above lengths terminate approximately 2 inches above floor. Page 15 TROUBLE SHOOTING CHART SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Flame too large 1. Defective operator section of valve. 1. Replace valve. 2. Burner orifice too large. 2. Check with local gas company for proper orifice size and replace. 3. If installed above 2,000 feet. 3. See orifice chart, page 10. Yellow burner flame 1. Clogged burner ports. 2. Obstructions around vent cap. 1. Remove main burner and check for obstructions in throat, ports, and orifices. Clean - but do not enlarge ports or orifices. 2. Make sure area around vent cap is clear, be sure vent system is sealed. Gas Odor 1. Gas leak. 1. See Page 1. Delayed Ignition 1. Pilot flame too small. 2. Burner ports clogged at pilot. 3. Low gas pressure. 4. Pilot decreases in size when main burners come on. 1. Adjust pilot flame. 2. Clean burner ports (do not enlarge). 3. Check gas supply pressure. 4. Supply piping is too small. Consult local gas company or competent installer. Fa...
Эта инструкция также подходит к моделям:Электрообогреватели - DVCF403B-R (239.21 kb)
Электрообогреватели - DVCF404B-R (239.21 kb)
Электрообогреватели - DVCF407B-R (239.21 kb)
Электрообогреватели - DVCF408B-R (239.21 kb)