Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Louisville Tin and Stove, модель VFM104

Производитель: Louisville Tin and Stove
Размер: 416.25 kb
Название файла: f2647992-9b68-4df7-b773-2c8367f18e4e.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


These installation instructions are a general guide and do not supersede applicable local codes and ordinances. Before planning or beginning the installation be sure it complies with all phases of the local heating code. Or, in the absence of local codes, with the latest edition of the National Fuel Gas Code, ANSI.Z223.1/NFPA54. A copy of which is available from the American Gas Association, 1515 Wilson Blvd., Arlington, Virginia 22209. The design of this appliance was certified to comply with the latest edition of ANSI Z21.11.2, also available from the American Gas Association. Page 2 INTRODUCTION – CONT’D. For your protection this heater is equipped with an Oxygen Depletion Sensor (ODS) pilot system. Never operate heater if ODS has been damaged or tampered with as this could expose you to Carbon Monoxide (a colorless, odorless gas) that could result in injury or death. Early signs of Carbon Monoxide poisoning resemble influenza, with headaches, dizziness, or nausea. If you develop these symptoms GET FRESH AIR AT ONCE. Turn off heater and call a qualified serviceman to check heater. Some people are more affected by Carbon Monoxide than others: Including pregnant women, persons with a heart or lung disease, anemia, those under the influence of alcohol, and those at high altitudes. OPERATION Infrared heaters “heat like the sun” with almost instantaneous, safe, clean burning “waves” of infrared heat. Like the sun, they must “see” the object to be heated. Make sure they are installed away from furniture or any other object which might block the infrared “waves”. The Cozy thermostatically controlled units offer the additional benefit of automatically cycling the heating to maintain just the right room temperature. Ventfree gas room heaters are designed strictly for “supplemental” room heat use and should never be installed as “sole source heating”. ROOM HEATER SPECIFICATIONS Your room heater comes packed in a single carton. Before installation, check the rating plate to verify that the Model Number is correct and that the room heater is equipped for the type gas you intend to use. MODEL NUMBER MANUAL MODELS THERMOSTAT MODELS NATURAL GAS VFM63 VFM103 VFM203 VFM303 VFT101 VFT201 VFT301 PROPANE GAS VFM64 VFM104 VFM204 VFM304 VFT102 VFT202 VFT302 TYPE CONTROL MAN. MAN. MAN. MAN. T-STAT BULB T-STAT BULB T-STAT BULB HEIGHT 22-1/2” 22-1/2” 22-1/2” 22-1/2” 22-1/2” 22-1/2” 22-1/2” WIDTH 11-1/2” 14-9/16” 20-11/16” 26-13/16” 14-9/16” 20-11/16” 26-13/16” DEPTH 7” 7” 7” 7” 7” 7” 7” INPUT (BTU/HR.) 5,500 10,000 LO / 10,000 HI / 20,000 LO / 10,000 MED./20,000 HI / 30,000 10,000 20,000 30,000 Gas Supply Line Size .” .” .” .” .” .” .” Optional CVF Blower NO NO YES YES NO YES YES Optional Floor Stand NO YES YES YES YES YES YES Bathroom Installation YES NO NO NO NO NO NO Bedroom Installation YES YES NO NO YES NO NO Piezo Ignitor YES YES YES YES YES YES YES Shipping Weight 16 LB. 22 LB. 30 LB. 35 LB. 22 LB. 30 LB. 35 LB. As applicable: 1. An unvented room hetaer having an input rating of more than 10,000 Btu per hour shall not be installed in a bedroom or bathroom; or 2. An unvented room heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom. SAFETY INSTRUCTIONS 1) Keep burner and control compartment clean. 2) Due to high temperatures, the heater should be located out of traffic and away from furniture and draperies. 3) Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition. 4) Young children should be carefully supervised then they are in the same room with this heater. 5) Do not place clothing or other flammable material on or near the heater. 6) Any safety screen or guard removed for servicing must be replaced prior to operating the heater. Page 3 SAFETY INSTRUCTIONS - CONTINUED 7) Installation and repair should be done by a qualified service person. ...

Эта инструкция также подходит к моделям:
Электрообогреватели - VFM103 (416.25 kb)
Электрообогреватели - VFM203 (416.25 kb)
Электрообогреватели - VFM204 (416.25 kb)
Электрообогреватели - VFM303 (416.25 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории