COMPLETE MILLIVOLT SYSTEM CHECK ("A" Reading - Thermostat contacts CLOSED - Control Knob “ON” - Main Burners should turn ON) a. If the reading is more than 175 millivolts and the automatic valve still does not come on - replace the valve. b. If the closed circuit reading ("A" reading) is less than 175 millivolts, determine cause for low reading - proceed as follows: B. THERMOPILE OUTPUT READING CHECK (“B” Reading - Thermostat contacts OPEN - Main burner OFF) Check gas pressure to the unit. If gas pressure is within minimum and maximum on data plate, then replace pilot. If the minimum millivolt reading is not obtainable, replace pilot. 16 58D6002 58D56002 17 PILOT HEAT THERMOSTAT REMOTE CONTROL Figure 14 - Installing T-Stat Sensor and Control Knob T-Stat Sensor Wiring Harnesses Screws Knob INSTALLING THERMOSTAT SENSOR (OPTION SOLD SEPARATELY) 1. Lift up on ash lip and pivot down to open control door. 2. Remove the face plate by removing the six (6) screws holding the faceplate in place. This will allow you to pull the faceplate away from the unit about 3" to 4". See Figure 13. 3. Slip the t-stat sensor behind the faceplate. Attach the t-stat sensor to the faceplate with 2 screws provided. Make sure the thermo bulb wire is on the bottom of the t-stat sensor. See Figure 14. 4. Attach wiring harnesses to back of t-stat sensor. See Figure 14. Attach the other ends of the harness to either TP/TH and TH on control valve or to existing wiring harness with two (2) 0.250" male spade terminals for remote t-stat operation. See Figure 12, page 16. ELECTRICAL WIRING (MILLI-VOLT) Figure 13 - Removing Face Plate from Unit Screws Face Plate Thermo Bulb Screws Control Door Ash Lip ELECTRICAL WIRING (MILLI-VOLT) 4. Remove adhesive backing from plastic clip. Press Valve clip to bottom of valve. Clip thermo bulb into plastic clip. See Figure 15. 5. Reattach faceplate or reinstall base. 6. Install knob to shaft of t-stat sensor. See Figure 14, page 17. Thermo Bulb Plastic Clip Figure 15 - Clipping Thermo Bulb into Plastic Clip. OPERATING THERMOSTAT SENSOR 1. Follow millivolt lighting instructions on lighting plate attached to unit or in homeowner.s manual. 2. With control knob in the “ON” position make sure the ON/OFF switch is in the “OFF” position. See Figure 16. 3. The unit is now being controlled by the thermostat sensor. The sensor will now cycle the burners on and off. You can adjust how often the unit cycles by turning the control knob on the sensor. PILOT OFF REMOTE CONTROL Pilot Optional Fan Hi/Lo Knob Piezo Ignitor Figure 16 - Control Knob in “ON” Position and ON/OFF Switch in “OFF” Position 18 58D6002 LOG PLACEMENT Before you begin — This unit is supplied with four ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling the logs, wash your hands gently with soap and water to remove any traces of fibers. The positioning of the logs are critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance. Never add additional logs or embellishments such as pine cones, Left Bottom Log #2 Back Log #1 Top Left Log #4 INSTALLING LOGS ON GRATE (See Figure 17) 1. Install back log (#1) on rear log support bracket. 2. Install left bottom log (#2) on left log support bracket in front of back log. 3. Install right bottom log (#3) on right log support bracket in front of back log. 4. Install top left log (#4) on top of left bottom log. 5. Install top right log (#5) on top of right bottom log. Figure 17 - Installing Logs to Grate vermiculite or rock wool to the heater. Only use the logs supplied with the unit. Failure to position the parts in accordance with diagrams below or to use only parts specifically approved for this heater may result in property damage or personal injury. WARNING During initial operation of the new heater, burning logs will give off a paper burning smell and orange flames will be present. Simply open the windows for a few hours to vent the odor. CAUTION Right Bottom Log #3 Right Top Log #5 Rear Log Support Bracket Left Log Support Bracket Right Log Support Bracket 58D56002 19 20 58D6002 PILOTOFFREMOTE CONTROL Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition, periodically check the flames visually during operation. CHECKING PILOT FLAME The pilot flame must always be present when the heater is in operation. It should just touch the top of the ther- mocouple tip for natural. See Figure 19 for correct pilot flame. If the pilot flame does not touch the thermocouple, then the burners cannot function reliably. See Figure 20 for incorrect shape of pilot flame. MILLI-VOLT CONTROL Figure 19 - Correct Appearance of Pilot Flame Figure 20 - Incorrect Appearance of Pilot Flame Thermocouple for Natural Thermocouple for LP Thermocouple for LP Thermocouple for Natural RO...

Эта инструкция также подходит к моделям:
Электрообогреватели - CSVF20SNV (2.28 mb)
Электрообогреватели - CSVF20SPV (2.28 mb)
Электрообогреватели - CSVF30SPV (2.28 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории