Войти:
Оценок - 5, средний балл: 4.2 ( )

Инструкция по эксплуатации Epson, модель P)-1

Производитель: Epson
Размер: 4.53 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


WARNING: The nearest point of the vent cap should be a minimum horizontal distance of six (6) (1.83m) feet from any pressure regulator. In case of regulator malfunction, the six (6) foot (1.83m) distance will reduce the chance of gas entering the vent cap. 24632-0-0508 Page 13 Page 14 24632-0-0508 INSTALLATION INSTRUCTIONS OVERVIEW Figure 4 Figure 5 Figure 6 Location - All Models Select a location near the center of the space to be heated. Overflow heat will circulate through doorways into adjacent rooms. The furnace is to be located on an outside wall. Locate wall studs so that wall opening will be located between wall studs. One wall stud can be used for attachment of inside wall plate. The wall opening required as shown in Figure 3 is a minimum diameter of 6 1/4" (159 mm). The inside wall plate and the outside wall plate are large enough to permit a wall opening diameter of 8" (203 mm). A template is provided in furnace carton for positioning furnace on the wall. Also, refer to Figure 3 for positioning the furnace on wall and for locating gas line connection. Figure 3 For large homes or spread-out floor plans, two or more furnaces are recommended. Do not locate furnace where a door could swing over the outer casing, or where circulation could be retarded by furniture or cabinets. See Figure 4. Do not install in a closet, alcove or small hallway where the furnace could be isolated by closing doors to the heated space. See Figures 5 and 6. When location is selected, check the walls to make sure there are no obstructions such as pipes, electric wiring, etc., which would interfere with the installation of the furnace or vent pipe. See Page 18, Box 4 for dimensions. 24632-0-0508 Page 15 1 Note: All references must be considered as if the observer is standing in front of the wall and/or appliance. HEATER TO BACK CASING MOUNTING SCREWS WALL MOUNTING TAB WALL MOUNTING SCREWS WALL MOUNTING PLATE Mark the venting system hole location (as indicated on page 18) and the six holes through the wall mounting plate. Drill accordingly. Insert the four wall anchors provided and tighten the wall mounting plate firmly. Use special anchor fasteners if the heater is to be installed on a wooden (hollow) wall. Line up the two (2) tabs on the top of the wall mounting plate with the holes in the back of the unit. Slide the back of the unit onto the tabs of the wall mounting plate. Secure the back of the unit into place using two (2) screws. Replace casing door. The heater is now ready to receive the venting system assembly from the opposite side of the wall. Note: All references must be considered as if the observer is standing in front of the wall and/or appliance. IMPORTANT: The venting system must be properly installed to insure proper and safe operation. The venting system must also be properly re-installed and re-sealed to insure proper and safe operation. INSTALLATION AND ASSEMBLY WARNING: Any change to this heater or its control can be dangerous. Provide adequate clearances and accessibility for purposes of servicing and proper operation. A manufactured home (USA only) installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 or, when such standard is not applicable, the Standard for Manufactured Home Installations, ANSI Z225.1. Due to high surface temperature, keep children, clothing, and furniture away. Keep burner and control compartments clean. INSTALLATION OVERVIEW WARNING: Improper installation, adjustments, alteration, service, or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency, or the gas supplier. These wall furnace models are designed for direct venting through a wall. Only venting components approved for these furnaces may be used. This unit is to be installed on a wall from 4 1/2" to 12" (114.3 mm to 304.8 mm) thick. Page 16 24632-0-0508 2 SILICON-BASED SEALANT MOUNTING PLATE CAP FLUE OUTLET TUBE AIR INLET TUBE Failure to position these parts in accordance with diagram or failure to use only parts specifically approved with these appliances may result in property damage or personal injury. 3 INSTALLATION OF HOUSEWARMER PRODUCT INSTALLATION AND ANY REPAIRS TO THIS APPLIANCE MUST BE DONE BY A QUALIFIED SERVICE PERSON. WARNING: Read the installation instructions thoroughly before cutting or drilling any holes for installation. WARNING: Do not remove any rating plates attached to the unit. CLEARANCES TO COMBUSTIBLES Allow clearances (for all models) to adjacent combustible construction. IMPORTANT: A qualified service person must install this appliance. Installation must conform to local codes, or in the absence of local codes, with the latest edition of the National Fuel Gas Code, ANSI Z223.1. A qualified service person should be called to inspect this appliance annually. Have all of your appliances checked annually. INSTALLATION AND ASSEMBLY INTERIOR PREPAR...

Эта инструкция также подходит к моделям:
Электрообогреватели - HWDV080DV(N (4.53 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории