Инструкция по эксплуатации Bryant, модель F)

Производитель: Bryant
Размер: 641.91 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


j Through the base connectors for gas and electric conduit/piping j Stainless steel gas heat exchanger (includes tubes, vestibule plate and collector box) j Economizer with dry bulb sensing and barometric relief j Economizer with enthalpy sensing and barometric relief j 2 position motorized outdoor air damper j Non- --fused disconnect j Powered 115- --volt convenience outlet j Non- --powered 115- --volt convenience outlet j High static evaporator fan motor j Return Air smoke detector j Supply Air smoke detector j CO2 sensor j Condenser hail guard - --louvered style OPTIONAL WARRANTIES j Complete Unit Parts only up to 5 years j Complete Unit Parts and Labor up to 5 years Many other optional warranties are available. See the Commercial Start- --Up and Optional Extended Warranty Price price pages for further information. FIELD INSTALLED ACCESSORIES j Economi$ert IV- --electromechanical, gear driven with Belimo actuator (2- --10v DC signal) and controller j Economi$ert2- --compatible with DDC controls; gear driven with Belimo actuator (4- --20mA) signal and no controller j Power exhaust j Two- --position motorized outdoor air damper j Manual outdoor air damper 25% j Manual outdoor air damper 50% j Roofcurb - --14 inch (356mm) tall j Roofcurb - --24 inch (610mm) tall j Thru- --the- --bottom connections- --electrical only j Thru- --the- --bottom connections- --electrical and gas j Condenser hail guard - --louvered style j Flue shield j Flue discharge deflector j Liquid propane (LP) conversion kit j High altitude conversion kit j Phase monitor (loss of phase/phase reversal) j Winter start kit, down to 25_F(- --4_C) j Low ambient head pressure controller, downto0_F(- --18_C) j Low ambient head pressure controller, down to - --20_F(- --29_C) j Time Guard II compressor anti- --cycle protection Economizer Sensors j Single Dry bulb control j Differential Dry bulb control j Single enthalpy control j Differential enthalpy control j CO2 - --wall mounted j CO2 - --duct mounted j CO2 - --unit mounted 580J***( D,F) 3 4 CERTIFIED DIMENSION 580J*08, 12D C08500 580J***(D,F) 5 CERTIFIED DIMENSION 580J*08, 12D C08501 580J***(D,F) 6 CERTIFIED DIMENSION 580J*14D C08502 580J***(D,F) 7 CERTIFIED DIMENSION 580J*14D C08503 580J***(D,F) 8 ROOF CURB DETAILS 580J*08, 12, 14(D,F) ROOFCURB ACCESSORY CRRFCURB003A01 CRRFCURB004A01 1’ - 2” (356) 2’ - 0” (610) UNIT SIZE C08547 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. E2008 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 11/08 Replaces: NEW Catalog No.SUB580J---03 580J***(D,F) ...

Эта инструкция также подходит к моделям:
Электрообогреватели - 580J***(D (641.91 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории