Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Gas-Fired Products, модель 3374

Производитель: Gas-Fired Products
Размер: 519.25 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The log set is assembled during installation. The RUVSOD is equipped with a Honeywell control valve that allows thermostatic control, on/off switch or a remote switch (not supplied). The RUVSOD model incorporates variable regulators that allow you to adjust burner heat output between HIGH, (35,000 BTU), and LOW, (26,000 BTU). See the Operation Section for details. A push button Piezo ignitor is used to light the standing pilot. The pilot incorporates an Oxygen Depletion System (ODS/pilot) which will shut off gas flow to the burner in the event that sufficient fresh air becomes unavailable for continued safe operation. Fresh Air Requirements for Combustion and Ventilation WARNING This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home. Modern construction standards have resulted in homes that are highly energy-efficient and that allow little heat loss. Your home needs to breathe, however, and all fuel-burning appliances within it require fresh air in order to function properly and safely. Exhaust fans, clothes dryers, fireplaces, and other fuel burning appliances all use the air inside the building. If the available fresh air is insufficient to meet the demands of these appliances, problems can result. The Radiance Unvented heater has specific fresh air requirements. You must determine that these fresh air requirements will be met within the space where the appliance will be installed.The following information will help you insure that adequate fresh air is available for the heater to function properly. Provide For Adequate Ventilation Any space within a home can be classified in the following categories: 1) Unusually Tight Construction 2) Confined Space 3) Unconfined Space First, determine which classification defines the intended space. Unusually Tight Construction You must provide additional fresh air if the space falls into this classification. Unusually Tight Constructionis defined as construction wherein: a. walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm or less with openings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of the three criteria above, you must provide supplemental fresh air for the appliance from outside the home as detailed on page 7, B. If your home does not meet the above criteria, follow the procedure below. Determine if You Have a Confined or Unconfined Space Use the following formula to determine if you have a confined or unconfined space. Spaceis defined as the room in which you will install the heater plus any adjoining rooms with doorless passageways or ventilation grilles between the rooms. The National Fuel Gas Code defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 BTU per hour, (4.8 m3 per kw)...

Эта инструкция также подходит к моделям:
Электрообогреватели - 3370 (519.25 kb)
Электрообогреватели - 3379 (519.25 kb)
Электрообогреватели - 3372 (519.25 kb)
Электрообогреватели - 3371 (519.25 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории