Фрагмент инструкции


For operation of heater in closed rooms without flue refer to the instructions for installation (par. 4) • If a room thermostat is used, set maximum temperature on it. • Turn switch to position “ON” • Set the desired temperature on room thermostat. min 13 ft max 33 ft min 16 ft min 10 ft min 15 ft WARNING! Heaters equipped with heated nozzle do not start immediately or may stop for some seconds after start. This is normal and should not be considered a faulty condition. Reset after lockout and Reset of safety thermostat • The heater is equipped with a Reset pushbutton. When the heater locks out, the red lamp on the pushbutton (fig.1, No.2) lights up. In this case push the Reset button (see also the par. “Troubleshooting”) to restart the heater. • The heater is also equipped with a manual reset safety thermostat fixed in contact with the combustion chamber, that can be reached through the inspection cover. To reset the thermostat: unplug the heater, open the inspection cover and push the reset button on the thermostat body. Shut down. • Set switch to “OFF” to shut the flame off. The fan will go on rotating for about 1’45” to cool the heater down. The fan motor will automatically stop at the end of the aftercooling time, then the unit can be disconnected from mains. WARNING! Never disconnect the supply plug to stop the heater while in operation The large amount of heat produced could damage the components or activate the safety thermostat and therefore make the unit not function MAINTENANCE • Before carrying out any maintenance operation, disconnect the power plug. • Maintenance must be carried out by qualified personnel (see also par. 7) • The appliance must be thoroughly cleaned once a year to ensure good combustion and long life. • Clean periodically -the oil spraying nozzle and its filter; -the oil pump filter -the main fuel filter cartridge -the ignition electrodes -the fan blades -the inside of the appliance, using compressed air -the flame sensor with a mild detergent • Periodically check cables and electrical connections • Check the oil filter and replace if necessary. ENERCO GROUP, INC. |Indirect Fired Portable Heater 4 Operating Instructions and Owner’s Manual TROUBLESHOOTING TROUBLE Heater does not start CAUSE •No power •Faulty cable/connections •Burnt fuse •Room thermostat set too low •Thermostat socket cap not inserted •The safety thermostat has been activated SOLUTION •Check main distribution board and power supply line •Check/have cable replaced by a qualified electrician •Check and replace if required •Set room thermostat on a higher temperature •Insert cap into the thermostat socket •Reset the safety thermostat Heater starts, flame ignites but then heater locks out •Dirty or faulty flame sensor •Faulty burner control unit •Clean or replace •Contact service personnel Heater starts, flame does not ignite and then heater locks out •Clogged nozzle •Flame sensor receives an external light signal during ignition sequence •Faulty burner control unit •No fuel •Ignition fault, dirty or incorrectly spaced electrodes •Clean or replace •Check for external lights (sun, lamps, etc.) •Contact service personnel •Fill tank •Clean electrodes, contact service personnel if required Heater starts, but combustion is not good •Dirty or blocked nozzle •Clogged filters •Leakes in fuel circuit •Oil pump provides low pressure •Insufficient combustion air •Insufficient ventilation air •Clean or replace •Clean or replace •Check and eventually replace •Contact service personnel •Wrong air lock setting •Contact service personnel Heater stops due to safety thermostat •The appliance has overheated •Faulty safety thermostat •Contact service personnel •Contact service personnel WIRING DIAGRAM ENERCO GROUP, INC. |Indirect Fired Portable Heater 5 Operating Instructions and Owner’s Manual EV Fuel Solenoid Valve TR Ignition Transformer M Motor SL Warning Lamp TS Safety Thermostat FS Fuse FC Flame Sensor PL Reset Button IN Switch TH Room Thermostat (Optional) FR Heated Filter (Optional) ENERCO GROUP, INC. |Indirect Fired Portable Heater 6 Operating Instructions and Owner’s Manual THIS PAGE INTENTIONALLY LEFT BLANK. ENERCO GROUP, INC. |Indirect Fired Portable Heater 7 Operating Instructions and Owner’s Manual by SIAL OPERATING INSTRUCTIONS AND OWNER’S MANUAL Model # HS180ID HS300ID WARNING: USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY. PARTS ORDERING INFORMATION: PURCHASING: Accessories may be purchased at any Mr. Heater/HeatStar local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll-Free 800-251-0001 • Our office hours are 8:30 AM – 5:00 PM, EST, Monday through Friday. Email to: techservice@enerco-mrheater.com Please include the model number, date of purchase, and description of problem in all communication. LIMI...

Эта инструкция также подходит к моделям:
Электрообогреватели - HS180ID (86.53 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории