|
Фрагмент инструкции
OFM RLA — — Outdoor (Condenser) Fan Motor Rated Load Amps 44 Table 12 — Electrical Data, 48ZG,ZN060 Units NOMINAL VOLTAGE (3 Ph 60 Hz) VOLTAGE RANGE COMPR NO. 1 COMPR NO. 2 OFM IFM BASE UNIT ONLY EXHAUST FAN BASE UNIT WITH EXHAUST FAN RLA LRA RLA LRA Total FLA Hp FLA MCA MOCP Total Hp Total FLA MCA MOCP 208/230 187-254 108 506 108 506 26.4 15 46.2/42 314.9/310.7 400/400 10 15 20 34/30 48/44 62/56 348.3/340.7 363.3/354.7 376.6/366.7 450/400 450/450 450/450 20 59.4/54 328.1/322.7 400/400 10 15 20 34/30 48/44 62/56 361.5/352.7 376.5/366.7 389.7/378.7 450/450 450/450 450/450 25 74.8/68 343.5/336.7 450/400 10 15 20 34/30 48/44 62/56 376.9/366.7 391.9/380.7 405.1/392.7 450/450 450/450 500/500 30 88.0/80 356.7/348.7 450/450 10 15 20 34/30 48/44 62/56 390.1/378.7 405.1/392.7 418.3/404.7 450/450 500/500 500/500 40 114.4/104 384.8/372.7 450/450 10 15 20 34/30 48/44 62/56 418.2/403.1 433.2/416.7 445.9/428.7 500/500 500/500 500/500 460 414-508 50.6 253 50.6 253 13.2 15 21.0 148.1 175 10 15 20 15.2 22.0 28.0 163.3 170.1 176.1 200 200 200 20 27.0 154.1 200 10 15 20 15.2 22.0 28.0 169.3 176.1 182.1 200 225 225 25 34.0 161.1 200 10 15 20 15.2 22.0 28.0 176.3 183.1 189.1 225 225 225 30 40.0 167.1 200 10 15 20 15.2 22.0 28.0 182.3 189.1 195.1 225 225 225 40 52.0 179.4 225 10 15 20 15.2 22.0 28.0 194.6 201.4 207.4 225 250 250 575 518-632 39.1 176 39.1 176 9.6 15 17.0 114.6 150 10 15 20 12.2 18.0 22.0 126.8 132.6 136.6 150 150 175 20 22.0 119.6 150 10 15 20 12.2 18.0 22.0 131.8 137.6 141.6 150 175 175 25 27.0 124.6 150 10 15 20 12.2 18.0 22.0 136.8 142.6 146.6 175 175 175 30 32.0 129.6 150 10 15 20 12.2 18.0 22.0 141.8 147.6 151.6 175 175 175 40 41.0 139.6 175 10 15 20 12.2 18.0 22.0 151.3 157.1 161.1 175 175 200 LEGEND NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan FLA — Hp — IFM — LRA — MCA — MOCP — Full Load Amps Nominal Horsepower Indoor (Supply) Fan Motor Locked Rotor Amps Minimum Circuit Amps (for wire sizing) Maximum Overcurrent Protection motors rated at 0.3 FLA each. OFM RLA — — Outdoor (Condenser) Fan Motor Rated Load Amps 45 Table 13 — Electrical Data, 48ZG,ZN070 Units NOMINAL VOLTAGE (3 Ph 60 Hz) VOLTAGE RANGE COMPR NO. 1 COMPR NO. 2 OFM IFM BASE UNIT ONLY EXHAUST FAN BASE UNIT WITH EXHAUST FAN RLA LRA RLA LRA Total FLA Hp FLA MCA MOCP Total Hp Total FLA MCA MOCP 208/230 187-254 108 506 142 690 33.0 15 46.2/42 364.8/360.6 500/500 10 15 20 34/30 48/44 62/56 398.2/390.6 413.2/404.6 426.4/416.6 500/500 500/500 500/500 20 59.4/54 378.0/372.6 500/500 10 15 20 34/30 48/44 62/56 411.4/402.6 426.4/416.6 439.6/428.6 500/500 500/500 500/500 25 74.8/68 393.4/386.6 500/500 10 15 20 34/30 48/44 62/56 426.8/416.6 441.8/430.6 455.0/442.6 500/500 500/500 500/500 30 88.0/80 406.6/389.6 500/500 10 15 20 34/30 48/44 62/56 440.0/428.6 455.0/442.6 468.2/454.6 500/500 500/500 600/500 40 114.4/104.0 433.0/422.6 500/500 10 15 20 34/30 48/44 62/56 466.4/453.0 481.4/466.6 494.1/478.6 600/500 600/600 600/600 460 414-508 50.6 253 65.4 345 16.5 15 21.0 169.9 225 10 15 20 15.2 22.0 28.0 185.1 191.9 197.9 250 250 250 20 27.0 175.9 225 10 15 20 15.2 22.0 28.0 191.1 197.9 203.9 250 250 250 25 34.0 182.9 225 10 15 20 15.2 22.0 28.0 198.1 204.9 210.9 250 250 275 30 40.0 188.9 250 10 15 20 15.2 22.0 28.0 204.1 210.9 216.9 250 275 275 40 52.0 200.9 250 10 15 20 15.2 22.0 28.0 216.1 222.9 228.9 250 250 250 575 518-632 39.1 176 52.6 276 12.0 15 17.0 133.9 175 10 15 20 12.2 18.0 22.0 146.1 151.9 155.9 175 200 200 20 22.0 138.9 175 10 15 20 12.2 18.0 22.0 151.1 156.9 160.9 200 200 200 25 27.0 143.9 175 10 15 20 12.2 18.0 22.0 156.1 161.9 165.9 200 200 200 30 32.0 148.9 200 10 15 20 12.2 18.0 22.0 161.1 166.9 170.9 200 200 200 40 41.0 157.9 200 10 15 20 12.2 18.0 22.0 170.1 175.9 179.9 200 225 225 LEGEND NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan FLA — Hp — IFM — LRA — MCA — MOCP — Full Load Amps Nominal Horsepower Indoor (Supply) Fan Motor Locked Rotor Amps Minimum Circuit Amps (for wire sizing) Maximum Overcurrent Protection motors rated at 0.3 FLA each. OFM RLA — — Outdoor (Condenser) Fan Motor Rated Load Amps 46 Table 14 — Electrical Data — 48ZG,ZN075-105 Units UNIT SIZE NOMINAL VOLTAGE (3 Ph 60 Hz) VOLTAGE RANGE COMPRESSOR OFM IFM BASE UNIT ONLY OPTIONAL POWER EXHAUST FAN BASE UNIT WITH EXHAUST FAN No. 1 No. 2 No. 3 No. 4 RLA LRA RLA LRA RLA LRA RLA LRA Total FLA Hp FLA MCA MOCP Total Hp Total FLA MCA MOCP 075 460 414-508 50.6 253 65.4 345 — — — — 16.5 30 40.0 188.9 250 10 15 20 15.2 22.0 28.0 204.1 210.9 216.9 250 250 250 40 52.0 200.9 250 10 15 20 15.2 22.0 28.0 216.1 222.9 228.9 250 250 250 50 65.0 213.9 250 10 15 20 15.2 22.0 28.0 229.1 235.9 241.9 250 300 300 60 77.0 228.8 300 10 15 20 15.2 22.0 28.0 244.0 250.8 256.8 300 300 300 75 96.0 252.5 300 10 15 20 15.2 22.0 28.0 267.7 274.5 280.5 300 350 350 090 460 414-508 65.4 345 65.4 345 — — — — 19.8 30 40.0 207.0 250 10 15 20 15.2 22.0 28.0 222.2 229.0 235.0 350 250 300 40 52.0 219.0 250 10 15 20 15.2 22.0 28.0 234.2 241.0 247.0 250 300 300 50 65.0 232.0 250 10 15 20 ...
Эта инструкция также подходит к моделям:Электрообогреватели - WEATHERMASTER 48ZT (2.76 mb)
Электрообогреватели - WEATHERMASTER 48ZG (2.76 mb)
Электрообогреватели - WEATHERMASTER Z6 (2.76 mb)
Электрообогреватели - WEATHERMASTER Z8075-105 (2.76 mb)