Фрагмент инструкции
the fans are turning. ... the safety temperature regulator "(N5, see page 3, fig. 1) in the air outlet has switched off. ... the control signal Z1 of the charging control unit is applied at terminal A1/Z1 in the storage heater. ch c 23 For the Fitter 2. Installation Instructions 2.1 Technical Data 245 30 О о 650 The unit must be installed and connected by a specialist under consideration of these installation instructions. WSP 2010 WSP 3010 WSP 4010 WSP 5010 WSP 6010 WSP 7010 Width "B" mm 605 780 955 1130 1305 1480 Weight (with storage blocks) kg 118 169 220 271 322 373 Distance "X" mm 415 590 765 940 1115 1290 Connection * 3/N/PE - 50 Hz 400 V Power kW 2.0 3,0 4.0 5.0 6.0 7.0 Reference charging kWh 16.0 24.0 32.0 40.0 48.0 56.0 max. charging PH kWh 17.0 25.5 35.0 42.0 51.0 61.5 Storage blocks Number of packages (blocks) pcs. 6(12) 9 (18) 12 (24) 15 (30) 18 (36) 21 (42) Block weight kg 85 128 170 213 256 298 Control resistance кП 2.78 2.78 2.78 2.78 2.78 2.78 Supplementary heating (special accessories) Power kW 0.35 0.5 0.8 1.0 1.2 1.5 * WSP 2010 also with 1 /N/РЕ ~ 50 Hz 230 V connectable 24 For the Fitter 2.2 Technical Description (page 3, fig. 1) 1 Control panel 2 Cover 3 Right side wall 4 Front wall 5 Air outlet grille 6 Air inlet grille 7 Fluff screen 8 Inside front wall 9 Storage blocks 10 Cover plate 11 Thermal insulation 12 Floor thermal insulation 13 Mixing air flap 14 Air duct 15 Cable duct 16 Air guidance assembly 17 Heating element 18 Fan 19 Safety temperature regulator - discharging (N5) 20 Safety temperature regulator - charging (N4) 21 Safety temperature limiter (FI) 2.2.1 Function Principle The storage blocks are heated up by the heating elements between the rows of storage blocks. Charging is set continuously with the charging control unit (selector knob fig. 17) Start and duration of the charging time are determined by the responsible electricity supply company. Two built-in safety temperature regulators (19, 20) and a safety temperature limiter (21) prevent overheating of the unit. Whilst the safety temperature regulators switch on again automatically, the safety temperature limiter must be switched back on by the technician by pressing in the knob in the middle of the limiter after eliminating the cause of the error. The heat stored in this way is then discharged with the aid of a fan, also partly through the heater surface. In this case, the room air is sucked in through the air inlet grille (6) by the fan (18) and blown through the air ducts of the storage blocks (9) which heats them up. Before being output through the air outlet grille (5) the hot air generated in this way is mixed via two mixing air flaps with colder room air so that the emitted air does not exceed the maximum permissible temperature. The position of the mixing air flap and thus the mixing ratio of the air is controlled by a bi-metal controller. 25 For the Fitter 2.2.2 Reducing the Output By moving or removing bridges at the terminals, the connection rating, factory wired to 100 °/o can be reduced by three levels (see the table). The dimensioning of the line cross sections and the fusing should correspond to the maximum possible output of the unit. A single-phase connection may be made according to the "Technical connection conditions" of / 7 \ the energy supply company only up to 2 kW (WSP 2010). Power variants kW 8h heating elements (series) 6h heating element fitt (special accessory ng set Connection variants (D 100 % © 91.6 % (3) 83.3 % ® 75% © 100% CD 100 % © 91.6% 83.3 % ® 75% Model WSP 2010 2.0 1.83 1.67 1.50 2.0 2.7 2.47 2.25 2.03 WSP 3010 3.0 2.75 2.50 2.25 - 4.1 3.75 3.42 3.07 WSP 4010 4.0 3.66 3.33 3.00 - 5.5 5.04 4.58 4.13 WSP 5010 5.0 4.58 4.16 3.75 - 6.5 5.96 5.42 4.88 WSP 6010 6.0 5.50 5.00 4.50 1 - 8.1 7.42 6.75 6.08 WSP 7010 7.0 6.42 5.83 5.25 - 9.0 8.24 7.5 6.75 О 100 % P w rated (series wiring) 3 2 1 L3 L2 Ll X1 IN I L3 I L21 L1 3/N/PE - 50 Hz 400 V © 91.6% P ) \ 3 2 1 L3 L2 Ll я; XI L3 1 L21 Ll 3/N/PE - 50 Hz 400 V © 83.3 rated L3 L2 L1 X1 In IL3iL21li 3/N/PE - 50 Hz 400 V © 75 % P rated 3 2 1 L3 L2 Ll X1 I L3 I L2l Ll 3/PE - 50 Hz 400 V © 100 0/0 Prated 2kW 3 2 1 L3 L2 L1 4„ u4 XI L1 1/N/PE ~ 50 Hz 230 V 2.3 Rules and Regulations • Pay attention to the packing slip! • The national building and garage regulations must be taken into account. • The installation area must have a sufficient floor load capacity. In case of doubt a building surveyor should be consulted (for weights of the storage heaters, see "Technical Data"). • The minimum distance from adjacent object surfaces must be kept (figs. 2 and 2a). • All electrical connection and installation work must be performed in accordance with the ...
Эта инструкция также подходит к моделям:Электрообогреватели - WSP 4010 (482.51 kb)
Электрообогреватели - WSP 2010 (482.51 kb)
Электрообогреватели - WSP 5010 (482.51 kb)
Электрообогреватели - WSP 6010 (482.51 kb)