See the safety information on the sides of the heater. WARNINGS: Hot while in operation. Do not touch. Keep children, clothing and furniture away. Do not light or operate where gasoline and other liquids having flammable vapors are present. RMC-LC10, RMC-LI10 & LI06 Only Fig. 8 Control knobs LIGHTING INSTRUCTIONS MANUAL GAS CONTROL 1. Stop! Read and Heed the Warnings and Cautions on the side of the heater. 2. Check that gas supply to the heater is on. 3. Push in gas control knob slightly and turn clockwise to “OFF” position. NOTE: knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force. 4. Wait five (5) minutes to clean out any air. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information on the side of the heater. If you do not smell gas, go to the next step. 5. Push in gas control knob slightly and turn counterclockwise to "PILOT/IGN” and depress for five (5) seconds. NOTE: The first time that the heater is operated after connecting the gas supply, the control knob should be depressed for about thirty (30) seconds. This will allow air to bleed from the gas system. 6. Release control knob and turn clockwise to "OFF". 7. Depress control knob while "OFF", then turn back to to "PILOT/IGN”. This should cause the spark from the piezo ignitor to light the pilot gas. Keep control knob depressed for ten (10) seconds before releasing. If pilot does not light, repeat steps 5, 6 and 7 or use a match. 8. When pilot is lit, turn the ignition knob to "ON". 9. To select the heating level desired, use the knob LOW to HIGH. THERMOSTAT GAS CONTROL 1. Stop! Read and Heed the Warnings and Cautions on the side of the heater. 2. Check that gas supply to the heater is on. 3. Push in gas control knob slightly and turn clockwise to “OFF” position. 4. Wait five (5) minutes to clean out any air. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information on the side of the heater. If you do not smell gas, go to the next step. 5. Turn control knob counterclockwise to “PILOT” position. Press in control knob for five (5) seconds. NOTE: The first time that the heater is operatedafter connecting the gas supply, the control knob should be depressed for about thirty (30) seconds. This will allow air to bleed from the gas system. 6. With control knob pressed in, push down and release ignitor button. This will light pilot. If needed, keep pressing ignitor button until pilot lights. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. 8. If pilot goes out, repeat steps 5 through 7 or use a match. 9. When pilot is lit, turn control knob to on.Turn control knob counterclockwise to desired heating level between 5 and 1. TO TURN OFF GAS TO APPLIANCE TO TURN OFF GAS TO APPLIANCE Fig. 9 Proper pilot flame MANUAL GAS CONTROL Turning Heater Off Push in gas control knob slightly and turn clockwise to "OFF" position. Do not force. Turning Burner Only Off (Pilot stays lit). Turn control knob clockwise to the PILOT position. CAUTION: Do not try to adjust heating levels by using the manual shut-off valve. NOTE: The thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size, ect.). Frequent use of your heater will let you determine your own comfort levels. THERMOSTAT GAS CONTROL Turning Heater Off Turn control knob clockwise to “OFF” position. Turning Burner Only Off (Pilot stays lit). Turn control knob clockwise to the PILOT position. CAUTION: Do not try to adjust heating levels by using the manual shut-off valve. NOTE: The thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size, ect.). Frequent use of your heater will let you determine your own comfort levels. MANUAL LIGHTING INSTRUCTION Fig. 10 Correct burner flame pattern for the RMC-LC blue flame burner. 1. Use a long match or a BBQ lighter. If not available, remove guard assembly by flexing it. 2. Follow steps 1 through 4 as stated under Lighting Instructions. 3. Press and turn control knob counterclockwise to the PILOT/IGN position 4. With control knob pressed in, strike match, hold match to pilot until pilot lights. 5. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. 6. Replace guard assembly if it was removed in step 1. PILOT AND BURNING INSPECTION Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figures 9, 10 and 11. If flame patterns are incorrect, turn the heater off. Contact your dealer or qualified gas technician for assistance. Do not operate the heater until the pilot flame is correct. WARNING: If yellow tipping occurs, yo...
Эта инструкция также подходит к моделям:Электрообогреватели - (F) (585.79 kb)
Электрообогреватели - (F) - 2 (585.79 kb)
Электрообогреватели - RMC-LC10LP - 10 (585.79 kb)
Электрообогреватели - RMC-LC10NG, RMC-LC20NG(F), RMC-LC30NG(F), RMC-LC10NG(T), RMC-LC20NG(T),(F), RMC-LC30NG(T),(F), RMC-L (585.79 kb)