Фрагмент инструкции


Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak that must be corrected. Correct all leaks at once. 6. Close propane supply valve. 4 Dayton Operating Instructions and Parts Manual Model 3VH20 Operation Review and understand the warnings in the General Safety Information section. They are needed to safely operate this heater. Follow all local codes when using this heater. TO START HEATER 1. Follow all installation, ventilation, and safety information. 2. Locate heater on stable and level surface. Make sure strong drafts do not blow on heater. 3. Make sure regulator is set to OFF by turning control knob clockwise. 4. Open propane supply valve on propane tank(s) slowly. 5. Turn regulator knob counterclockwise to “HI”. 6. Push in and hold automatic control valve button (See Figure 5). Press and release piezo ignitor button (See Figure 5). Keep pressing piezo ignitor button until the burner lights. Hold control knob down for a maximim of 10 seconds while attempting ignition. If heater does not ignite, release control knob and wait 3 minutes before attempting reignition. Piezo Ignitor Automatic Control Valve Button Figure 5 - Automatic Control Valve Button and Piezo Ignitor Button Locations NOTE: Keep hands and face away from outlet (around top of shell) of heater while attempting to start heater. 7. After ignition, hold automatic control valve button down for approximately 30 seconds. This activates the automatic control system. 8. When burner remains lit, set heater at the desired heat level by turning the regulator knob counterclockwise. If burner goes out, turn off gas. Turn regulator knob fully clockwise to OFF. Check fuel supply. If adequate fuel is available, restart heater beginning at Step #1. Heat Settings Figure 6 - Heater Regulator TO STOP HEATER 1. Tightly close propane supply valve by turning clockwise. Allow heater to burn remaining fuel in the hose. 2. Turn regulator knob to the OFF position. Wait 20 minutes for the heater to cool before handling heater. 3. Always remove the gas supply hose from the heater and the propane tank after each use. TO RESTART HEATER 1. Wait five minutes after stopping heater. 2. Restart heater by following steps under To Start Heater. Storage Disconnect heater from propane supply tank(s). 1. Do not store heater while attached to propane tank. Remove the gas supply hose from the propane tank by turning the fuel gas connector nut clockwise. 2. Store propane tank(s) in safe manner. Refer to Chapter 5 of Standard for Storage and Handling of Liquified Petroleum Gases, ANSI/NFPA 58. Follow all local codes. Always store propane tanks outdoors. Never store propane tank in an enclosed area. 3. Place plastic cover caps over brass fittings on inlet connector and hose/ regulator assembly. 4. Store in a dry, clean, and safe place. Maintenance Never attempt to service heater while it is connected to propane supply, operating, or hot. Severe burns can occur. 1. Keep heater clean. 2. Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak that must be corrected. Correct all leaks at once. 3. Inspect hose/regulator assembly before each use. If hose is highly worn or cut, replace. 4. Have heater inspected yearly by a qualified service person. 5 Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 3VH20 For Replacement Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: Address parts correspondence to: -Model number Grainger Parts -Serial number (if any) P.O. Box 3074 -Part description and number as shown in 1657 Shermer Road parts list Northbrook, IL 60065-3074 U.S.A. Figure 7 - Replacement Parts Illustration 1 2 3 5 8 6 4 7 Replacement Parts List Use only original replacement parts. This heater must use design-specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fatal injuries. This will also protect your warranty coverage for parts replaced under warranty. Reference Number Description Part No. Quantity 1 Shell Assembly 101880-01 1 2 *Thermocouple Bracket 103933-01 1 3 Thermocouple Kit 099236-01 1 4 Burner Assembly Kit (Includs Automatic Control Valve, 101864-01 1 Hardware, and Instruction Sheet) 5 Piezo Ignitor (Includes Nut) 102445-01 1 6 Ignitor 101878-01 1 7 Regulator (Complete With Regulator And Fuel LPA2025 1 Gas Connector) 8 Regulator/Fuel Gas Connector/Hose Assembly LPA3025 1 . Operation Tag 101860-07 1 . Tradename Decal 099153-07 1 . **10’ Hose With Brass Fitting LPA1025 1 (.) Not shown. (*) NOTE: Attach Thermocouple Bracket with #4-40 Bolt/Nut (Standard Hardware Available Locally). (**) Total length of hose should not exceed 20 feet from tank/cylinder. 6 Dayton Operating Instructions and Parts Manual Model 3VH20 Troubleshooting Chart Never attempt to service heater while it is connected to propane supply, operating, or hot. Severe...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории