Фрагмент инструкции


If you see globules of water in the bottom, drain and flush the tank and filter with clean fuel, b. Refill with fresh, clean fuel. FORM 5S1792 MODELS 2E510A, 2E511 A, 3E218A & 3E219 01582. Trouble Shooting Chart (Continued) SYMPTOMS POSSIBLE CAUSE(S) CORRECTIVE ACTION Heater burns, but puffs 2. Dirty air filters causing reduced 2. Remove and clean the air filters. of smoke can be seen; air flow through nozzle, resulting Be sure air intake is not blocked. heater will not burn in low fuel flow steady; heater burns 3. Fuel filter loose, dirty, or 3a. Remove and wash fuel filter in yvith odor; heater smokes connection loose clean fuel. continuously. / M £ a M . a A J \ b. Check condition of connection ^C/OntinUGu) > c. between fuel line and burner. Replace with new fuel line. 4. Dirty nozzle 4a. b. c. Remove and clean the burner head. Blow compressed air through nozzle from outlet end. Never use a drill, wire or other tool to open a nozzle passage. 5. Fan blade 5. Check for excessive dirt accumulation on fan blade which could be causing motor to slow down. 6. Loose air output line connections 6. Be sure connections are tight. between filter housing and burner. 7. Rubber sleeve on shank of nozzle is leaking. (Remote possibility). 7. If heater puffs intermittently, replace the rubber sleeve. (Handle parts carefully to prevent damage; assemble them carefully to preserve airtightness.) Improper Fuel-Air Mixture (Too much fuel, or not enough air for amount of fuel being supplied) Flames come from front 1. Dirty fan 1. Clean the fan. of heater. 2. Air passageway through heater 2. Be sure the air passageway through blocked by dirt or trash the heater is clean. Keep the heater clean. 3. Fan loose or improperly located 3. Check fan; correct if not right. on shaft 4. Bent or damaged fan 4. Replace. Do not attempt repair of fan. 5. High pump pressure 5. Check and adjust pressure. 6. Air intake blocked 6. Check filters. Electrical System Troubles Heater cycles 1. Thermostat (if used) set too low 1. Set thermostat to a higher temperature intermittently. for more even operation. 2. Damaged thermostat (if used) 2. Replace a damaged thermostat. 3. Low voltage causing tripout of safety control 3. Check power line voltage. Use extension cord with proper size wire. 4. Damaged electrical supply or 4a. Be sure extension cord and heater damaged connections b. service cord are in good condition, without intermittent open circuits. Check mechanical and electrical soundness of all wiring connections in the heater and service cord. Heater ignites, but 1. Damaged photo cell 1. Check to see if glass face of cell is so dirty it can’t “see” the flame; dean glass button of safety control circuit breaker pops if dirty. Replace with a cell that is known out anyway. to be good. 2. Damaged safety control 2. Replace with a control that is known to be good. 3. Damaged electrical connections in circuit through cell and control 3. Be sure all solder joints and wiring connections are secure. Check wiring diagram. Safety control circuit 1. Damaged circuit breaker 1a. Replace with a circuit breaker that is breaker fails to trip known to be good. when a no-flame b. Replace with a new printed circuit board. condition exists. (Model 3E218A only). 2. Control dirty or damaged 2a. Replace damaged control with one that is known to be good. FORM 5S1792 MODELS 2E510A, 2E511A, 3E218A & 3E219 01582 Trouble Shooting Chart (Continued) SYMPTOMS POSSIBLE CAUSE(S) CORRECTIVE ACTION Safety control circuit breaker fails to trip b. Replace the printed circuit board. (Model 3E218A only). when a no-flame condition exists. (Continued) 3. Photocell electrical leads shorted 3. Check photo cell leads for shorted leads. Replace photo cell if damaged. Button on safety control circuit breaker won’t 1. Resetting is tried too soon after the breaker trips. 1. Wait 5 minutes and try again. stay in when pressed. ! 2. Damaged circuit breaker 2a. b. Replace with a circuit breaker that is known to be good. Replace with a printed circuit board. (Model 3E218Aonly). 3. Photo cell circuit open 3. Check photo cell for open condition. Replace if damaged. Figure 2 — Replacement Parte Mkjsfralion for Heater Models 2E51OA & 2E511A FORM 5S1792 MODELS 2E510A, 2E511 A, 3E218A & 3E219 01582 Replacement Parts List for Heater Models 2E510A & 2E511A REF. 2E510A 2E511A NO. PART NO. DESCRIPTION QTY. QTY. 1 M51104-01 Handle 1 1 2 M50901-01AZ Upper shell 1 1 3 M50589-01 Handle screw 2 2 - 4 M11084-27 Hex head screw #10-16 x 1/2 6 6 c ÎM50785-02 Assembly combustion chamber 1 — D IM50785-04 Assembly combustion chamber — 1 6 M10908-2 Hex head screw #6-32 x 3/8 ; 2 2 7 M16660 Photo cell bracket 1 1 8 M16656-9 Photo cell assembly , 1 1 Q ÎM29707-04 Burner head assembly 1 — IM29707-03 Burner head assembly — 1 10 M11084-26 Hex head screw #10-16 x 3/8 2 2 ...

Эта инструкция также подходит к моделям:
Электрообогреватели - 3E218A (859.02 kb)
Электрообогреватели - 3.00E+219 (859.02 kb)
Электрообогреватели - 2E511A (859.02 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории