Войти:
Оценок - 3, средний балл: 3.3 ( )

Инструкция по эксплуатации United States Stove, модель 1600

Производитель: United States Stove
Размер: 335.52 kb
Название файла: 7fca6d76-d2f7-4480-98ce-427c685e7378.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


From rear side of door place With two 1/4" x 3/4" hex bolts, attach the door latch to the 1/2" washer over threaded part of door handle. Then attach 1/2" lock nut, being careful not to over tighten. Handle should turn freely. BAFFLE ROD EXTENSION HEX COUPLING BAFFLE ROD1-1/2" 2 1 3 5 4 6 1/2 BRICK MODEL 1600 (41/2) BRICKS MODEL 1800 (6) FULL BRICKS 1 3 4 5 6 2 THE MODELS 1600 AND 1800 HAVE BEEN EQUIPPED WITH DIFFERENT PLENUM OPENINGS, THEY ARE AS FOLLOWS: door latch mounting bracket on the left side of door frame as 7 illustrated. Adjust latch until door closes securely. MODEL 1800 18"x18" Square Plenum Opening REAR OF FIREBOX TOP 6 The firebrick must be inserted on each side resting on the BRICK INSTALLATION (PRE-INSTALLED AT FACTORY) NOTE: Prior to operation, be sure to remove brick retaining strips. FIREBOX: 1 2 3 SMOKE DOOR CLIPS 1/4" LOCK NUTS 1/4" X 1-1/4" CARRIAGE BOLTS FRONT OF FURNACE SMOKE DOOR FUEL LOADING DOOR FRAME grate frame. First, place cut brick in each back corner. Place remaining brick in place. SMOKE CHAMBER: 1. Place #1 firebrick in the back of smoke chamber. 2. Slide baffle plate into smoke chamber, flat side down. 3. Place remaining firebrick in smoke chamber as SPIN DRAFT CAP 1/2" X 2-1/2" CARRIAGE BOLT 1/2" LOCK NUT 7 MOUNTING PROCEDURE FOR DRAFTS DRAFT TUBE CLAMP MOTORIZED NATURAL DRAFT OPTIONAL MOTORIZED NATURAL DRAFT Models 1600 / 1800 1. Using (2) 1/4" x 1" bolts, lock washers and nuts, attach draft to furnace with draft tube clamp. 2. Plug draft power cord into receptacle on front of furnace. MODEL 1600/1800 KIT #C60357M FORCED AIR DRAFT (SHIPPED WITH UNIT) 1. Using (2) 1/4" x 1" bolt, lock washer and nut, attach draft MODEL 1600/1800 adapter bracket to furnace draft tube. KIT #69189 8 DRAFT WIRING DIAGRAM ALL WIRING MUST BE DONE BY A QUALIFIED ELECTRICIAN Predrilled holes are provided on the back of the furnace for mounting the fan center electrical box. Mounting holes and knockouts are also provided to accommodate mounting the high limit control in either the upper left or upper right corner. The flexible conduit connecting the high limit control to the fan center electrical box has been sized longer for the model 1800. This conduit may be cut shorter to provide a cleaner installation on model 1600. 9 FAN CENTER HIGH LIMIT CONTROL THERMOSTAT TO THERMOSTAT TO "R" TO "G" FAN CENTER W W W W L1 1 3 WIRES TO BLOWER MOTOR PLASTIC KNOB SET SCREW NUT PUNCH GR FLEXIBLE CONDUIT TO HIGH LIMIT CONTROL BLK BLUE RED BLK BLK BLUE BLACK RED TO DRAFT BLK ELECTRICAL BOX 2 BLACK BLUE Wired to "G" on fan center front Wired to "G" on fan center front Red- To Draft Black- To High Limit GND REAR VIEW 3-SPEED SWITCH MODEL "B" SHOWN (SEE WIRING DIAGRAM ON PAGE 10 FOR WIRING OF MODEL "A" SWITCH) HOUSE CURRENT ELECTRICAL INSTALLATION SWITCH LABEL CONDUIT TO HOUSE CURRENT ALL WIRING MUST BE DONE BY A QUALIFIED ELECTRICIAN LOAD FAN LINE LOAD LIMIT LINE BREAK OFF JUMPER FOR LOW VOLTAGE FAN "OFF" INDICATOR (100) FAN "ON" INDICATOR (150) LIMIT INDICATOR (200) Honeywell LIMIT SWITCH 2 23 4 5 1 L1 33-SPEED SWITCH (Two Models are available Model "A" and Model "B". Check your switch to see which model you have and wire accordingly) RED RED RED RED RED WHITE WHITE WHITE WHITE BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLUE BLUE BLUE GREEN 1400 CFM 1250 CFM 1100 CFM TO "R" TO "G" BLOWER MOTOR SETTING LIMIT CONTROL WALL THERMOSTAT DRAFT MOTOR FAN CENTER ELECTRICAL BOX POWER SUPPLY WIRING DIAGRAM BACK VIEW FRONT VIEW R C W G Y Model "A" Model "B" LOAD FAN LINE LOAD LIMIT LINE BREAK OFF JUMPER FOR LOW VOLTAGE FAN "OFF" INDICATOR (100) FAN "ON" INDICATOR (150) LIMIT INDICATOR (200) Honeywell LIMIT SWITCH 2 23 4 5 1 L1 33-SPEED SWITCH (Two Models are available Model "A" and Model "B". Check your switch to see which model you have and wire accordingly) RED RED RED RED RED WHITE WHITE WHITE WHITE BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLUE BLUE BLUE GREEN 1400 CFM 1250 CFM 1100 CFM TO "R" TO "G" BLOWER MOTOR SETTING LIMIT CONTROL WALL THERMOSTAT DRAFT MOTOR FAN CENTER ELECTRICAL BOX POWER SUPPLY WIRING DIAGRAM BACK VIEW FRONT VIEW R C W G Y Model "A" Model "B" 10 TESTING AND OPERATING PROCEDURES TESTING: 1. If using an optional power draft, check the draft blower by turning the room thermostat up high enough so that the draft blower turns on. Then lower the thermostat setting until you hear it shut off. 2. Use a sheet of newspaper to test your draft by placing it inside the furnace and lighting it. With completion of the tests above, you are ready to light the furnace. Follow the operating steps. STARTING A WOOD FIRE Using Motorized Natural Draft CAUTION: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or "freshen up" a fire in the furnace. Keep all such liquids well away from the furnace while it is in use. 1. Turn up thermostat to open motorized damper. 2. Open spin draft cap on ash door. 3. Pull the slide baffle rod to the front position. 4. Open the fu...

Эта инструкция также подходит к моделям:
Электрообогреватели - 1800 (335.52 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории