Войти:
Оценок - 1, средний балл: 5 ( )

Инструкция по эксплуатации Sunbeam Bedding, модель HE2300

Производитель: Sunbeam Bedding
Размер: 1.76 mb
Название файла: 86f3b7f8-012c-4e0c-8b97-3e669fee1012.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left unattended. • Always unplug the heater when not in use. • Do not use outdoors. • Do not run the cord of the heater under carpeting. Do not cover the cord with throw rugs, runners or other floor coverings. Arrange the cord away from traffic areas where it will not be tripped over. • Do not locate the heater immediately below a socket outlet. • Do not use this heater in the immediate surrounds of a bath, shower, laundry area or swimming pool. • Do not insert or allow foreign objects to enter any ventilation or exhaust openings as this may cause electric shock or fire, or damage to the heater. • To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, such as beds, where opening may become blocked. • A heater has hot and arcing or sparing parts inside. Do not use it in areas where petrol, paint or flammable liquids are used or stored. • In order to avoid overheating, do not cover the heater. Important instructions – retain for future use. If you have any concerns regarding the performance and use of your appliance, please visit or contact the Sunbeam Consumer Service Line. Ensure the above safety precautions are understood. Sunbeam’s Total Safety System Safety auto shut off Your Sunbeam Twinheat Ceramic Heater is equipped with a safety system that detects any abnormally high temperatures within the heater and automatically shuts it off to prevent overheating. Thermal back-up fuse In addition to this automatic cut-off, your heater contains a thermal back-up fuse to provide additional back-up protection. If the heater is in an overheat situation, the back-up fuse will open, stopping the power flow to the heating element and fan. This fuse cannot be reset, so in the event that the back-up fuse is activated, the heater will need to be replaced. Power ON light Illuminates to indicate that the heater is connected to the power outlet and is switched on. Ceramic element The 2400 watt ceramic element is more efficient than other element types as it converts more electricity into heat that is transferred into the room. It also self-regulates the energy flow depending on the temperature for added safety. If the ceramic gets too hot, electricity cannot pass through it. Ceramic elements are safer than other element types, as they operate at temperatures below the ignition temperature of highly flammable materials like tissue paper. Oscillation function The heater oscillates 70 degrees to provide greater heat distribution. Simply press the OSC button (OSC) to activate this function. Two heat settings Two heat settings allow you to adjust the heat and airflow of the heater. When using the thermostat, select setting 2 to reach the desired heat level more quickly. Fan setting Ideal for circulating cool air in summer, the fan setting operates the fan without heat. Features of your Oscillating Twinheat Ceramic Heater Thermostat dial The adjustable thermostat allows you to select the desired heat level, and automatically switches the heater on and off to maintain the desired temperature. Twin housing The revolutionary vertical twin housing has a 90 degree swivel on separate elements to provide wider heat distribution. Mode selector dial The mode selector dial operates the heater. Select heat setting 1 or 2, or fan. • Using your heater HE 00 Oscillating Twinheat Ceramic Heater 1.Place the heater on a flat level surface and ensure that the air intake and outlet are clear of obstructions. 2.Insert the plug into a 230/240V power outlet and turn the power on. 3.Turn the thermostat dial to the highest setting by rotating the dial clockwise as far as it will turn. 4.Turn the mode dial to the desired heat setting, I or II. 5.To use the fan without heat, set the thermostat dial to the lowest setting and select the fan setting on the mode selector dial. Setting the thermostat 1.Set the thermostat to the highest setting by turning the dial clockwise as far as it will turn. 2.When the room has reached the desired temperature level, lower the thermostat setting by turning the thermostat dial anti- clockwise until it clicks. The heater will stop operating. 3.The thermostat is now set and will automatically maintain the pre-set temperature level by switching between the high (II) and low (I) settings. Note: When set to the high setting it is normal for the heater to cycle between high and low as it maintains the preset temperature. The heat output does not vary when the heater is set to the low heat setting (I). To prevent the unit from cycling, raise the thermostat setting. Adjusting the swivel housing The revolutionary vertical twin housing allows heat to travel in two different directions for maximum heat distribution. Carefully rotate each housing to direct the airflow in the desired direction. Do not swivel the unit beyond the point of resistance. Using ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории