Войти:
Оценок - 1, средний балл: 4 ( )

Инструкция по эксплуатации Sunbeam, модель SLP3300-CN

Производитель: Sunbeam
Размер: 636.63 kb
Название файла: SLP3310-CN_English.pdf
Язык инструкции:enfr
Перейти к скачиванию



Фрагмент инструкции


14AWG minimum size and rated not less than 1875 watts. 17. If the heater will not operate, see specific instructions under Auto Safety Shut-off on resetting the heater. 18. DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only. 19. DISCONTINUE USE IF PLUG OR OUTLET IS HOT. RECOMMEND OUTLET BE REPLACED IF PLUG OR OUTLET IS HOT TO TOUCH. PLEASE SAVE THESE INSTRUCTIONS CONSUMER SAFETY INFORMATION THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS SAFETY FEATURE IN ANY WAY. PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS NOTE: • There may be an odor coming from the heater the first time you use it or after long periods of storing. This is normal during the break-in period. Make sure the heater is in a well ventilated area and continue running it until the smell goes away. • You may hear a popping or crackling sound as the heater heats up. This is normal and safe operation. Once the heater heats up, the crackling sound will go away. TECHNICAL SPECIFICATIONS Wattage: 1500W/ (+ 5% - 10%) Working Voltage: 120V AC/60 Hz Amperage: 12.5A ENERGY EFFICIENT HEAT & $AVE™™ TECHNOLOGY (AVAILABLE ON MODEL SLP3310-CN ONLY) The heater will automatically cycle between 1500 and 750 watts. To activate the Heat & $ave™ cycle depress the Heat & $ave™ button. The Heat & $ave™ cycle can be deactivated by depressing the Heat & $ave™ button. In this case, the heater will run continuously at 1500 watts. AUTO SAFETY SHUT-OFF This heater is equipped with a patented, technologically advanced, safety system that automatically shuts off the current to the heater when a potential overheat temperature is reached. The heater can only resume operation when you reset it. To Reset the Heater If your heater shuts down, follow these steps: 1. Turn Power to OFF. 2. Unplug the heater and wait 30 minutes. 3. Plug in the heater, turn the power ON. 4. Your heater should now be operating properly. Tip-Over Shut-Off If the heater is knocked over, it will instantly shut off. To resume operation, simply place the heater in an upright position and turn ON the heater. PRE-OPERATING INSTRUCTIONS 1. Make sure the heater is OFF before plugging the heater into the outlet. 2. Place the heater on a firm, level surface. 3. Avoid overloading your circuit by not using other high wattage appliances in the same outlet. At 1500 Watts, this unit draws 12.5 Amps. 4. Make sure unit and plug is free of moisture and debris before plugging into an electrical outlet. operating inStructionS SLP3310 (Fig. 1) 1. Press the On/Off button to turn unit on. 2. Select temperature by pressing the Temperature button until the desired temperature is chosen. 3. Set the Timer for the duration in which you would like the heater to run. 4. Then choose whether or not you would like to use the Heat & $ave™ Technology by pressing the Heat & $ave™ button. Fig. 1 (SLP3310) SLP3300 (Fig. 2) 1. To turn heater On simply turn knob to desired heat level, 1 or 2. 2. Select desired temperature by turning the thermostat knob. Fig. 2 (SLP3300) cleaning/Maintenance Always unplug the heater before cleaning and allow to cool. • Lightly run a vacuum cleaner nozzle over the heater grill to remove any dust or dirt that may have accumulated. • Carefully wipe the heater with a soft, damp cloth. Please be very cautious near the heating elements. • NEVER use abrasive or flammable solvents to clean the heater. • After cleaning, be sure to completely dry the heater with a cloth or towel. • Store your heater in a cool, dry dust-free location. troubleSHooting If your heater fails to operate or if there is no heat: • Do NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void the warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only. • Make sure the power button is ON – depress button or turn knob to High. • Check the thermostat setting; it might be set too low. Turn the thermostat knob clockwise until the heater restarts. • If the unit is still not producing enough heat, or Thermostat is set to the highest setting. • Be patient. Give the heater time to heat up. If your heater shuts down, follow these steps: • Turn Power to OFF. • Unplug the heater and wait 30 minutes. • Plug in the heater, turn the power ON. • Your heater should now be operating properly. • Make sure the electrical outlet and circuit breaker are working. • You may hear a popping or crackling sound as the heater heats u...

Эта инструкция также подходит к моделям:
Электрообогреватели - SLP3310-CN (636.63 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории