Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Sunrise Global, модель 13-05020

Производитель: Sunrise Global
Размер: 697.65 kb
Название файла: 8fc89cef-cc68-4cb7-ba97-327538598965.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Air conditioner diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Remote control operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6 Safety notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-11 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Installation setup diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Installation location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15-19 Electrical wiring - indoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-17 Electrical wiring - outdoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Air purging and leakage test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Test operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Important notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Thank you for choosing this GREE mini-split heat pump, please keep this owner’s manual with proof of purchase for reference. SAFETY PRECAUTIONS SAFETY PRECAUTIONS Legend of symbols used in this manual : Not to do. Be sure to follow instructions. Grounding is necessary. Feature of the appliance (not a defect). Pay attention. Warning: Incorrect handling may cause serious hazards and/or injuries. Disconnecting switch Only to the attention of Keep clean and in good Use 110-120V~60Hz power electricians or technicians : working order the power supply only. To eliminate risks of short supply circuit breaker or plug. circuits and fire hazards, do To eliminate risks of electric not unplug the air conditioner shocks or fire hazards, make or switch off the circuit breaker sure the power supply cord is when unit is running. correctly plugged in. Always check the power Never insert fingers, foreign Do not expose skin or eyes supply cord or wire for signs of objects or anything to directly to cool air over adamages before installing and obstruct the air inlet and long period of time. using the air conditioner. If the outlet grilles of both insidepower cord is damaged, contact SUNRISE TRADEX Customer Service. and outside units. Warn children. Always close the air To eliminate risks of electric Do not put any combustionconditioner before cutting the shocks and fire hazards, do appliance in the direct path of power off when there is a not attempt to repair the air the unit airflow ; it could affect malfunction of the unit. conditioner by yourself. the combustion efficiency. Do not operate the unit with wet hands or spray water or other liquid inside the unit. Do not place any foreign objects on the outdoor unit. Make sure the air conditioner is well grounded according to local electricity codes and that the work is done by a qualified and certified electrician or technician. 2 AIR CONDITIONER DIAGRAM Actual model may differ from the diagram INDOOR UNIT Front case Air in DisplaySurface panel Air outLouvers Remote control Drain hose Air in Heating Cooling Auto Power/Run OUTDOOR UNIT Suction and liquid refrigerant piping and wiring Air out 3 REMOTE CONTROREMOTE CONTROL 2 AAA - 1.5V BATTERIES POWER THE REMOTE CONTROL. • Do not use rechargeable batteries How to insert the batteries 1. Following the arrows (see Figure), remove the battery cover. 2. Insert the 2 batteries, making sure that the terminals (+/-) are correctly fitted. Put the cover back into position. 3. Using the tip of a pen or any other sharp object, press on the ACL key. 4. Reinstall the cover. NOTE : • Don’t mix new with used batteries or batteries of different types. • If you are not using the remote control for a long period of time, remove the batteries to eliminate potential battery leakage. • The remote control should be kept at least 1 m or more away from the TV set or any other electric or electronic appliances. • Make sure there is nothing blocking the signal from the remote control to the inside unit. • Do not drop or throw the remote control. • Do not leave the remote control in a location exposed to direct sunlight or near a heat source. • Do not spray any liquid or immerse the remote control. 4 Two buttons to set the temperature When unit is running under AUTO, COOL, FAN, HEAT, press this button to se...

Эта инструкция также подходит к моделям:
Электрообогреватели - 13-05024 (697.65 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории