Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Generac, модель 004451, 004582

Производитель: Generac
Размер: 3.71 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Follow the hydrometer manufacturer's instructions carefully. Generally, a battery is considered to be at 100% state of charge when specific gravity of its fluid (as measured by hydrometer) is 1.260 or higher. 13 (.^^X)=^=3 Section 3 — Maintenance MAINTENANCE Commercial-Industrial-Residential Portable Generator System 3.1 MAINTENANCE SCHEDULE Follow the calendar intervals. More frequent service is required when operating in adverse conditions noted below. Operation Maintenance Daily Every Season Every Season Every Season Check Oil Level ✓ Service Air Pre-Cleaner ✓** Change Oil and Oil Filter}: ✓* Clean Spark Arrestor Screen ✓ Adjust Valve Clearance ✓ Service Air Cleaner ✓** Replace Spark Plugs ✓ } Change oil after first 8 hours of operation then every season. * Change oil and oil filter every month when operating under heavy load or in high temperatures. ** Clean more often under dirty or dusty operating conditions. Replace air cleaner parts if very dirty.. PRODUCT SPECIFICATIONS 3.2.1 GENERATOR SPECIFICATIONS MODEL GPS 12500 GPS 15000 Model # 004451-1 004582-1 Rated Max. Power 12.5 kW 15.0 kW Surge Power 18.75 kW 22.5 kW Rated AC Voltage 120/240 120/240 Rated Max AC Load Current @ 240V 52.0 Amps 62.5 Amps Current @ 120V 104.0 Amps 125.0 Amps Rated Frequency 60 Hz @3600 RPM Phase Single Phase Rated DC Voltage 12 Volts Rated Max DC Load Current @ 12 Volts 10 Amperes 3.2.2 ENGINE SPECIFICATIONS Rated Horsepower @ 3600 RPM 27 30 Displacement 760cc 992cc Spark Plug Type Champion RC12YC or Equivalent Spark Plug Gap 0.030 inch or (0.76 mm) Gasoline Capacity 16 U.S. gallons Oil Type Summer - SAE 30 or 10W-30 Winter - Synthetic 5W-20 or 5W-30 Oil Capacity w/Filter Change = 1.5 Qts. w/o Filter Change = 1.2 Qts. Run Time/Fuel Consumption-1/2 Load 10 Hours / 1.6 gallons per hour 14 Section 3 — Maintenance Commercial-Industrial-Residential Portable Generator System MAINTENANCE o 3.3 GENERAL RECOMMENDATIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual. Some adjustments will need to be made periodically to properly maintain the generator. All adjustments in the Maintenance section (3) of this manual should be made at least once each season. Follow the requirements in the "Maintenance Schedule" chart on page 14. NOTE: Once a year you should replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer. 3.3.1 GENERATOR MAINTENANCE_ Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material. Check the cleanliness of the generator frequently and clean when dust, dirt, oil, moisture or other foreign substances are visible on its exterior surface. A CAUTION! Never insert any object or tool through the air cooling slots, even if the engine is not running. Note: DO NOT use a garden hose to clean generator. Water can enter the engine fuel system and cause problems. In addition, if water enters the generator through cooling air slots, some water will be retained in voids and crevices of the rotor and stator winding insulation. Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings. 3.3.2 TO CLEAN THE GENERATOR_ * Use a damp cloth to wipe exterior surfaces clean. * A soft, bristle brush may be used to loosen caked on dirt, oil, etc. * A vacuum cleaner may be used to pick up loose dirt and debris. * Low pressure air (not to exceed 25 psi) may be used to blow away dirt. Inspect cooling air slots and openings on the generator. These openings must be kept clean and unobstructed. 3.3.3 ENGINE MAINTENANCE_ DANGER! When working on the generator, always disconnect negative cable from battery. Also disconnect spark plug wires from spark plug and keep wire away from spark plug. 3.3.4 CHECKING OIL LEVEL_ See the “BEFORE STARTING THE GENERATOR” section on page 10 for information on checking the oil level. The oil level should be checked before each use, or at least every eight hours of operation. Keep the oil level maintained. 3.3.5 CHANGING THE OIL AND OIL FILTER Change the oil and filter after the first eight hours of operation. Change the oil every 100 hours thereafter. If you are running this unit under dirty or dusty conditions, or in extremely hot weather, change the oil more often. Use the following instructions to change the oil while the engine is still warm: * Clean area around oil drain hose and plug. ...

Эта инструкция также подходит к моделям:
Электрогенераторы - 004451 ,004582 (3.71 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории