Войти:
Оценок - 3, средний балл: 3.3 ( )

Инструкция по эксплуатации Campbell Hausfeld, модель GN0800

Производитель: Campbell Hausfeld
Размер: 641.09 kb
Название файла:
Язык инструкции:enespt
Перейти к скачиванию



Фрагмент инструкции


Loose clothing or jewelry may become entangled in moving components, causing equipment damage and or personal injury. 9. Keep all persons away from parts that move or become hot during operation. 10. Be sure all powered devices are shut off prior to connecting them to the generator. 11. Keep the generator clean and well maintained at all times. ! WARNING Never operate this generator in an explosive atmosphere or poorly ventilated area. REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2002 Campbell Hausfeld / Scott Fetzer IN284700AV 9/02 Operating Instructions General Safety (Continued) 12. Be sure that all tools and appliances are in good repair and are properly grounded. Use devices that have three prong power cords. If an extension cord is used, be sure that it has three prongs for proper grounding. Do not operate this! WARNING generator on wet surfaces or in the rain. 13. Never operate the generator with damaged, broken or missing parts, or with any guarding components removed. ! DANGER Shut off the generator engine and disconnect the spark plug wire before performing any service or maintenance to the unit. 14. Do not refill the fuel tank while the engine is running. Use precautions to prevent fuel spillage during refills. Be sure the fuel tank cap is securely in place before starting the engine. Allow engine to cool for at least two minutes before refueling. 15. Be sure to store gasoline in clean containers that do not contain water, dirt or rust because this will cause the engine to shut down. Operation PRE-OPERATION 1.Check fuel every time you start your generator. Always use clean fuel – see #15 above. Use a 50:1 mix of gas and oil (2.6 ounces of oil to one gallon of gasoline). It is best to use 89 octane gasoline and a certified 2-cycle oil. 2. Use of a Ground Fault Circuit Interrupter (GFCI) is strongly recommended. Ground Fault Circuit Interrupters can significantly reduce the possibility of injury if an electrical short occurs. ALWAYS OPERATE YOUR NEVER OPERATE YOUR GENERATOR UNDER THESE GENERATOR UNDER THESE CONDITIONS: CONDITIONS: 1. Rain or inclement weather 2. Excessive vibration 3. Sparking 4. Engine misfire 5. Electric output loss 6. Changing or fluctuating engine speed 7. Overheating in connected equipment 8. Damaged receptacles 9. Damaged, broken or missing parts 10. Guarding components removed A Ground Fault ! WARNING Circuit Interrupter may not be effective if used on a generator that is not grounded! 3. When installing a GFCI, be sure to follow all national and local regulations, or call a licensed or certified electrical technician. GROUNDING 1. Use the ground terminal on the generator frame to connect the unit to a suitable ground source. Securely fasten the end terminal of the ground wire to the ground terminal on the generator frame. 2. The ground wire should be made of #8 gauge wire. Do not use wire with a higher gauge number. Higher gauge numbers indicate thinner wire, which may not provide an adequate ground path. 3. The other end of the ground wire must be securely fastened to an approved ground source. The following are ground sources approved by the National Electric Code. Other ground sources may be acceptable. Refer to the National Electric Code and local regulations for further ground source information. If not sure 1. Read and understand these instructions 2. Clear of all persons 3. Properly grounded (generator) 4. Properly grounded (tools, appliances, etc.) 5. Flat level surfaces 6. Well ventilated areas of regulations or procedures, obtain assistance from a qualified (licensed or certified) electrical technician. a. An underground water pipe at least ten feet in length. b. A non-corrosive underground pipe at least eight feet in length and 3/4 inch diameter. c. A steel or iron underground rod at least eight feet in length and 5/8 inch diameter. d. A non-ferrous rod at least eight feet in length, 1/2 inch in diameter, and approved for grounding purposes. Any rod or pipe used for grounding must be driven to eight feet deep or buried in the deepest possible trench. STARTING 1. Check fuel – Use a 50:1 mix of gas and oil (2.6 ounces of oil to one gallon of gasoline). 2. Remove all electrical loads from the generator. 3. Set the fuel switch to the open (vertical) position – pointing down. 2 GN0950 and GN0800 Operation (Continued) EXTENSION CORDS MAXIMUM RECOMMENDED LENGTHS (IN FEET) 4. Move the choke/run switch to the choke position. 5. Turn engine switch on by pressing the top of the switch. 6. Pull the starter rope with a brisk smooth motion. 7. Return choke/run switch to the run position. 8. After each start up, allow engine to run 2-3 minutes with no load. Engine speed is ! CAUTION preset to provide proper output voltage. Never attempt to modify or adjust engine speed or output voltage. ENGINE BREAK-IN The first 25 hours of operation is considered the break-in period for the engine. During this time, ...

Эта инструкция также подходит к моделям:
Электрогенераторы - GN0950 (641.09 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории