Войти:
Оценок - 3, средний балл: 3.3 ( )

Инструкция по эксплуатации Craftsman, модель MGP-679500

Производитель: Craftsman
Размер: 1.34 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Begin by removing the oil dipstick and plug. Start pouring the oil in slowly. The engine will hold approximately 26 ounces of oil. To 'heck the oil, clean and replace the dipstick. Do not ^crew the dip stick in when checking the oil level. Next, remove the dipstick to check the level. The oil dipstick is clearly marked with lines that tell you when the engine has enough oil. Do not fill above this point. NOTE: When adding oil to the engine crankcase, use a high quality detergent oil classified “For Service SF,SG,SH" rated SAE 30 weight. Use no special additives. Select the oil’s viscosity grade according to your expected operating temperatures. SAE Viscosity Grades MU 5W-3Q, 1DW-30 • 4 ; 1 1 I 1 î » ap « a « i ; . L1?_* -ac •0 10 * 1 ISTARTING TEMPERATURE RANGE ANTICIPATED BEFORE NEXT OIL CHANGE] 12 - Low Oil Shutdown Your Craftsman generator engine is equipped with Low Oil Shutdown. Low Oil Shutdown is a safety device designed to protect your engine from damage in the event the oil level in the crankcase is low. If while the engine is running, the oil gets low, it will automatically shut itself down and will not restart until the oil is added. If the oil is low before start-up, the generator will not start until oil is added. NOTE: The Low Oil Shutdown mechanism is very sensitive. You must fill the engine to the full mark on the dipstick to inactivate this safety device. Gasoline Your generator engine is 4 cycle. Use unleaded fuel only. Never mix oil with gasoline. CAUTION: Never fill fuel tank completely. Fill tank to 1/2" below the bottom of the filler neck to provide space for fuel expansion. Wipe any fuel spillage from engine and equipment before starting engine. WARNING: Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank. Use clean, fresh, regular unleaded gasoline with a minimum of 85 octane. Do not mix oil with gasoline. If unleaded fuel is not available, leaded fuel may be used. To Start Your Generator CAUTION: Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an ordorless and deadly gas. Make sure the fuel shutoff valve is turned to the open position. CLOSE OPEN • Remove gas cap. • Add unleaded gasoline, slowly, to fuel tank. • Do not overfill. • On the engine there is a start/off switch located on the front panel of the engine. Place this switch to the start position. • On the engine there is a choke/run lever. Place this lever to the choke position. FULL CHOKE POSITION • Grasp the starter handle and pull rope out slowly until it pulls harder. Let the rope rewind slowly. Then pull rope with a rapid full arm stroke. Let rope return to starter slowly. • When engine starts, gradually move choke lever to “No Choke Position”. • If the engine fails to start after (3) pulls, move the choke lever to the beginning choke position and pull start rope again. • For hot engine starts make sure choke lever is in the “No Choke Position". Connecting Electrical Loads • Let engine run and warm up for about five minutes after starting. • Plug in the desired 120 or 240 volts tools. • DO NOT connect 240 volt equipment to the 120 volt duplex receptacles. • DO NOT connect 3-phase loads to the panel receptacles. IMPORTANT: You should always add up the rated watts of all lights, tools and appliances you are powering at one time. This total should not exceed the rated capacity of you generator or circuit breaker rating of the receptacle supplying power. Stopping The Engine • Disconnect all electrical loads. • Switch the start/off switch to the off position. IMPORTANT: Never store engine with fuel in tank, indoors, or in enclosed, poorly ventilated areas or where fuel fumes may reach an open flame. MAINTENANCE CUSTOMER RESPONSIBILITIES TABLE MAINTNENANCE TASK before each use Every 25 Hours of Every Season Every 50 Hours of Every Season Every 100 Hours of Every Season Check oil level X See Note 2 Change oil See Note 1 Clean Air Filter Assembly X Check Spark Plug X X I Prepare Unit for Storage Prepare unit for storage if it is to remain idle for more than 30 days. Note 1: Change oil after first two (2) operating hours and every 50 operating hours thereafter, more often if operated in extreme dusty or dirty conditions. Note 2: Check oil after 5 hours of operation (See page 14 - ENGINE MAINTENANCE - Oil.) 13 - ENG GENERAL RECOMMENDATIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, operator must maintain the generator as instructed in this manual. Some adjustments will need to be made periodically to maintain your generator. GENERATOR MAINTENANCE Your generator should be kept clean and dry at all times. The generator should not be stored or operated in enviroments that includes excessive moisture...

Эта инструкция также подходит к моделям:
Электрогенераторы - 919.679500 (1.34 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории