Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Briggs & Stratton, модель 030248-0

Производитель: Briggs & Stratton
Размер: 3.08 mb
Название файла: 8708a37e-c802-4cd4-ad52-ff6c9f7842ef.pdf
Язык инструкции:enes
Перейти к скачиванию



Фрагмент инструкции


DO NOT use a defective screen. If screen is not damaged, clean it with commercial solvent. 4. Reattach screen and muffler guard. Air Cooling System Over time debris may accumulate in cylinder cooling fins and cannot be observed without partial engine disassembly. For this reason, we recommend you have an authorized Briggs & Stratton service dealer clean the cooling system per recommended intervals (see Maintenance Schedule in beginning of Maintenance section). Equally important is to keep top of engine free from debris. See Clean Debris. The carburetor on this engine is low emission. It is equipped with a non-adjustable idle mixture valve. Top speed has been set at the factory. If adjustment is required, see an authorized Briggs & Stratton service dealer. A CAUTION Excessively high operating speeds increase risk of injury and damage to generator. Excessively low speeds impose a heavy load._ • DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed. • DO NOT modify generator in any way. 16 BRIGGSandSTRATTON.COM Storage The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage. Generator Storage • Clean the generator as outlined in Cleaning. • Check that cooling air slots and openings on generator are open and unobstructed. Long Term Storage Instructions Fuel can become stale when stored over 30 days. Stale fuel causes acid and gum deposits to form in the fuel system or on essential carburetor parts. To keep fuel fresh, use Briggs & Stratton FRESH START™ fuel stabilizer, available as a liquid additive or a drip concentrate cartridge. There is no need to drain gasoline from the engine if a fuel stabilizer is added according to instructions. Run the engine for 2 minutes to circulate the stabilizer throughout the fuel system. The engine and fuel can then be stored up to 24 months. If gasoline in the engine has not been treated with a fuel stabilizer, it must be drained into an approved container. Run the engine until it stops from lack of fuel. The use of a fuel stabilizer in the storage container is recommended to maintain freshness. A WARNING M № Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death. WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK • Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors. WHEN DRAINING FUEL • Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank. • Drain fuel tank outdoors. • Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources. • DO NOT light a cigarette or smoke. Change Oil While engine is still warm, drain oil from crankcase. Refill with recommended grade. See Changing Engine Oil. Oil Cylinder Bore • Remove spark plug and pour about 1/2 ounce (15 ml) of clean engine oil into the cylinder. • Install spark plug and pull starter handle slowly to distribute oil. A WARNING M Unintentional sparking can result in fire or electric shock. NEVER crank engine with spark plug removed. Other Storage Tips 1. DO NOT store fuel from one season to another unless it has been treated as described in Long Term Storage Instructions. 2. Replace fuel container if it starts to rust. Rust and/or dirt in fuel can cause problems if it’s used with this unit. 3. Cover unit with a suitable protective cover that does not retain moisture. A WARNING Storage covers can be flammable. DO NOT place a storage cover over a hot generator. Let equipment cool for a sufficient time before placing the cover on the equipment. 4. Store generator in clean, dry area. 17 Maintenance Troubleshooting Troubleshooting Problem Cause Correction Engine is running, but no AC output is available. 1. One of the circuit breakers is open. 2. Fault in generator. 3. Poor connection or defective cord set. 4. Connected device is bad. 1. Reset circuit breaker. 2. Contact authorized service facility. 3. Check and repair. 4. Connect another device that is in good condition. Engine runs good at no-load but “bogs down” when loads are connected. 1. Short circuit in a connected load. 2. Engine speed is too slow. 3. Generator is overloaded. 4. Shorted generator circuit. 1. Disconnect shorted electrical load. 2. Contact authorized service facility. 3. See Don’t Overload Generator in Operation section. 4. Contact authorized service facility. Engine will not start; or starts and runs rough. 1. Rocker switch set to “Off”. 2. Fuel Valve is in “Off” position. 3. Dirty air cleaner. 4. Out of fuel. 5. Stale fuel. 6. Spark plug wire not connected to spark plug. 7. Bad spark plug. 8. Water in f...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории