Инструкция по эксплуатации DeVillbiss Air Power Company, модель D26968

Производитель: DeVillbiss Air Power Company
Размер: 832.03 kb
Название файла: 844de6de-8706-4af7-bb21-068b7842320e.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


If while the engine is running, the oil gets low, it will automatically shut itself down and will not restart until the oil is added. If the oil is low before start-up, the generator will not start until oil is added. NOTE: The Low Oil Shutdown mechanism is very sensitive. You must fill the engine to the full mark on the dipstick to inactivate this safety device. OFF/RUN/START SWITCH Placed in the start position to start engine and the off position to stop engine. NOTE: When engine is running switch will remain in the run position. 13- ENG . IDLE CONTROL Choose the correct application. 1. For normal application such as power tools, small electric appliances, light bulbs, and radios: Place the idle control switch in the ON position. The generator will idle down when there is no load. This lowers the engine noise, saves on fuel consumption, and engine life. 2. Idling down IS NOT recommend on large motors (refrigerators, freezers, etc) or voltage sensitive electronic equipment (computers, televisions, etc). For these applications: Place the idle control switch in the OFF position. 12V DC OUTLET IMPORTANT: Allow generator to run at no load for 5 minutes upon each initial start-up to allow engine to stabilize. IMPORTANT: When the unit is running the battery will charge. DO NOT connect the 12V DC cables to the generator’s battery. To charge battery: 1. Using the 12V DC cables supplied, connect the red positive (+) 12V DC cable to the battery's positive (+) terminal. 2. Attach the other end of the red positive (+) 12V DC cable to the generators positive (+) 12V DC outlet. 3. Connect the black negative (-) 12V DC cable to the battery's negative (-) terminal. 4. Attach the other end of the black negative (-) 12V DC cable to the generators negative (-) 12V DC outlet. 5. Charge the battery according to battery or equipment manufacturer recommendations. BEFORE START UP This generator has been shipped from the factory without oil in the crankcase. Operating the unit without oil can damage the engine. Always check engine oil level before every start. Running engine low of oil or out of oil could result in serious damage to the engine. Follow the steps listed below before starting generator: 1. Check engine oil. Refer to the Engine Operator's Manual for correct grade and quantity of oil. 2. Check fuel level, fill as required. Make sure generator is turned off and has been allowed time to cool down. Use clean, fresh, regular unleaded gasoline with a minimum of 87 octane. Do not mix oil with gasoline. Never fill fuel tank completely. Fill tank to 1/2" below the bottom of the filler neck to provide space for fuel expansion. Wipe any fuel spillage from engine and equipment before starting engine. . 14- ENG Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank. Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an odorless and deadly gas. 3. Make sure generator is grounded in accordance with local requirements. 4. All electrical loads MUST be disconnected. 5. Idle control switch must be in the OFF position. Engine speed has been factory set to provide safe operation. Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire. Never attempt to “speed-up” the engine to obtain more performance. Both the output voltage and frequency will be thrown out of standard by this practice, endangering attachments and the user. You MUST unplug any load from the generator before starting to prevent permanent damage to any appliances. TO START THE ENGINE Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an odorless and deadly gas. 1. Open the fuel shut-off valve. 2. Move the choke control located on the engine to "CHOKE" position. A cold engine may require to be choked longer than a warm engine. 3. Push ON\OFF\START switch on control panel to the "START" position to start engine. Hold in "START" position no longer than 15 seconds per minute when trying to start engine. Extended cranking can damage the starter motor. 4. When engine starts, gradually move the choke to the "NO Choke" position. IMPORTANT: Allow generator to run at no load for 5 minutes upon each initial start-up to allow engine and generator to stabilize. STOPPING ENGINE 1. Disconnect all electrical loads. 2. Place the ON\OFF\START switch to "OFF" position. 3. Close fuel shut-off valve. CONNECTING ELECTRICAL LOADS 1. Let engine run and warm up for five minutes after starting with no electrical load. Connect loads in the following manner to prevent damage to equipment: 2. Connect inductive load equipment first, inductive loads consist of refrigerators, freezers, water pumps, air conditioners, or small hand tools. Connect the items that require the most wattage first. See Wattage Calculation Section in this manual. 3. Connect the lights next. 15- ENG . 4. Voltage...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории