Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Chicago Electric, модель 66619

Производитель: Chicago Electric
Размер: 622.74 kb
Название файла: 66619.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


REV 09c THIS UNIT CAN POWER THE FOLLOWING ITEMS ITEM RUNNING WATTS START-UP WATTS Ten 75 Watt Light Bulbs 750 1/4HP Compressor 600 900 1/6HP Motor 500 800 3/8” Drill 400 600 Mini Refrigerator 400 700 15 Amp Battery Charger 380 String Trimmer 350 500 Table/Box Fan 200 300 Radio 50 NOTE: Wattages listed above are estimates for that type of equipment only. Check nameplate wattages on all loads before connecting to Generator. Operating Instructions Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product. To prevent serious injury: Operate only with proper spark arrestor installed. Operation of this equipment may create sparks that can start fires around dry vegetation. The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements. Note: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram near the end of this manual. Starting the Engine Inspect the Generator looking for damaged, loose, and missing parts before set up and starting. If any problems are found, do not use the unit until properly repaired. Checking and Filling The Fuel Tank: CAUTION! Your Warranty is VOID if the Engine’s Fuel Tank (73) is not filled with the proper mixture (50:1) of unleaded gasoline and 2-cycle oil before each use. Before each use, check the fuel level. Do not run the Engine with an improper unleaded gasoline/2-cycle oil mixture. Running the Engine with an improper mixture WILL permanently damage the Engine. The Fuel Tank (73) holds approximately 1. 1 gallon of fuel. FIGURE B1 GALLONUNLEADEDGASOLINE2.5 FLUID OUNCES2-CYCLE OILAPPROVEDCONTAINER 2. To obtain the proper gasoline and 2-cycle oil mixture, mix 2.5 fluid ounces of 2-cycle oil with 1 gallon of unleaded gasoline into an approved container. Then slowly shake the container to thoroughly mix the gasoline/2-cycle oil. (See Figure B.) REV 10b FIGURE CFUELTANKCAP(76) STRAINER(74) 3. Remove the Fuel Tank Cap (76) and check the fuel level. (See Figure C.) WARNING! To prevent serious injury from fire: Fill the Fuel Tank (73) in a well- ventilated area away from ignition sources. Do not smoke. To fill the Fuel Tank (73), first wipe off the 4. Fuel Tank Cap (76) and the surrounding area. (See Figure C.) Unscrew, and remove the Fuel Tank Cap 5. (76). (See Figure C.) Remove the Strainer (74) and remove 6. any dirt and debris. Then replace the Strainer. (See Figure C.) Fill the Fuel Tank (73) to about 1 inch 7. under the fill neck of the Tank with the pre-mixed unleaded gasoline/2-cycle oil mixture. Then replace the Fuel Tank Cap (76). 8. (See Figure C.) Start Procedure: Before starting the Engine: Inspect the Generator and Engine.a. Fill the Fuel Tank (73) with the b. proper amount and type of unleaded gasoline and 2-cycle oil. (See Figures B and C.) NOTE: Only after the Generator c. has stabilized and is running smoothly should an appliance or tool be plugged into the AC Outlet of the Generator. FIGURE DFUELSWITCH(80) “OPEN” 1. Turn the Engine Fuel Switch (80) to its “OPEN” position. (See Figure D.) FIGURE E“CHOKE” “RUN” CHOKELEVER(82) 2. Turn the Engine Choke Lever (82) to its “CHOKE” position. Set the Choke Lever in the “RUN” position when starting a warm Engine. (See Figure E.) FIGURE F“ON” POWERSWITCH 3. Then turn the Engine Power Switch to its “ON” position. (See Figure F.) FIGURE GRECOILSTARTERHANDLE(42) 4. Grasp the Recoil Starter Handle (42) and pull slowly until resistance is felt. While holding the Handle, allow the Starter Rope to rewind slowly. Then, pull the Starter Handle with a rapid, full arm stroke. Once again while holding the Handle, allow the Rope to rewind slowly. Repeat as necessary, until the Engine starts. (See Figure G.) FIGURE HCHOKELEVER(82) “RUN” “CHOKE” 5. After the Engine starts and warms up, slowly move the Choke Lever (82) to its “RUN” position. (See Figure H.) IMPORTANT: Allow the Engine to run at 6. no load until warm (approx. 3 minutes) after each start-up to allow the Engine to stabilize. Break-in Period: Breaking-in the Engine will help to 1. ensure proper equipment and Engine operation, and will extend the Engine’s lifespan. The warranty is void if the Engine is not broken in properly. The first 25 hours of operation is the break-in period. During this time frame, DO NOT • exceed 75% of the Generator’s load limit. In other words, the maximum load during this break-in period should be no more than 600 watts. After the first 25 hours of use:• Change the unleaded gasoline/2-cycle • oil fuel mixture. Under normal operating conditions subsequent maintenance follows the schedule explained in the Maintenance and Servicing section. Equipment Operation Load And Circuit Breaker: The total combined load through the 1. outlet on the Generator must not exceed the rated maximum power (800 watts) of the unit. FIGURE IRESETOFFCIRCUITBREAKER 2. Always r...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории