Инструкция по эксплуатации Alto-Shaam, модель 1000-SK/II

Производитель: Alto-Shaam
Размер: 2.63 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


17 TrOUBLE ShOOTINg chEcKLIST SErVIcE TrOUBLE ShOOTINg chEcKLIST SErVIcE Error code Description Possible cause E-10 cavity air sensor shorted Cavity air sensor reading < 5°F. Verify sensor integrity. See sensor test instructions below. E-11 cavity air sensor open Cavity air sensor reading > 517°F. Verify sensor integrity. See sensor test instructions below. E-20 Product probe is shorted Oven will cook in time only Product probe reading < 5°F. Verify sensor integrity. See sensor test instructions below. E-21 Product probe is open Oven will cook in time only Product Probe reading > 517°F. Verify sensor integrity. See sensor test instructions below. E-30 Under temperature Unit has not reached set-point for more than 90 minutes. E-31 Over temperature Unit has been higher than 25°F above the maximum cavity set-point formore than 2 minutes. Note: Holding Cabinets with this error code aremore than 145°F higher than the maximum set-point. E-50 Temp. measurement error Contact factory. E-51 Temp. measurement error Contact factory. E-60 real time clock error Data set to factory default. Ensure that date and time are correct if applicable. E-61 real time clock error Contact factory. E-70 configuration connector error (DIP switch) Refer to wiring diagram for the particular model and ensure dip switches onthe control match the settings called out on the WD. If the dip switch settingsare correct according to the print replace the control. E-78 Voltage low Voltage below 90 VAC on a 125 VAC unit, or below 190 VAC on a208-240 VAC unit. Correct voltage. E-79 Voltage high Voltage over 135 VAC on a 125 VAC unit, or over 250 VAC on a208-240 VAC unit. Correct voltage. E-80 EEPrOM Error Ensure that all temperatures and times are properly set. Contact factory if problem persists. E-81 EEPrOM Error Contact factory. E-82 EEPrOM Error Contact factory. E-83 EEPrOM Error Contact factory. E-85 EEPrOM Error All timers, if previously on, are now off. Possible bad EEPROM. E-86 EEPrOM Error Stored HACCP memory corrupted. HACCP Address reset to 1. Possible bad EEPROM. Contact factory if problem persists. E-87 EEPrOM Error Stored offsets corrupted. Offsets reset to 0. Control may need a recalibration. Possible bad EEPROM. Contact factory if problem persists. E-88 EEPrOM Error All timer set-points are reset to 1 minute. Timers, if previously on, are nowoff. Possible bad EEPROM. E-90 Button stuck A button has been held down for >60 seconds. Adjust control. Error will reset when the problem has been resolved. E-dS Datakey error Datakey digital signature incompatible. Cycle power, and install compatibleDatakey if error persists. E-dT Datakey error Datakey incompatible with control. Install compatible Datakey. E-dU Datakey unplugged Install Datakey and cycle power to control to clear error. Note: If in doubt, always cycle the power to the control and contact factory if the problem persists. To test probe and air sensor: Tes t probe and air sensor by placing sensor in ice water bath and using an ohmmeter set on the ohm scale. The reading should be 100 ohms resistance. If it is more than 2 ohms higher or lower, sensor needs to be replaced. simple control smokers • installation/operation/service manual -pg. 18 simple control smokers • installation/operation/service manual - pg. 19 service A 7 6 1 5 10 9 30 31 29 28 27 26 25 15 12 14 17 16 18 19 22 21 20 18 11 32 DETAIL A 34 35 36 37 2 3 4 13 23 24 8 33 Part numbers and drawings are subject to change without notice. SERVICE VIEW - single compartment (1000-SK/II Shown) DANgEr DIScONNEcT UNIT frOM POwEr SOUrcE BEfOrE cLEANINg Or SErVIcINg. DANgEr LOcK-OUT Or POST BrEAKEr PANEL UNTIL SErVIcE wOrK hAS BEEN cOMPLETED. A SErVIcE PA SErVIcE PArrTTSS LLIST - ssiinnggllee ccoommppaarrttmmeenntt A MODEL > 767-SK 1000-SK/II ITEM DEScrIPTION PArT NO. QTY PArT NO. QTY 1 TOP COVER 1011872 1 1011534 1 2 PLUG, HOLE 3/8" PG-25574 1 PG-25574 1 3 PLUG, DOME, 187" HOLE PG-28439 6 PG-28439 6 4 BUSHING, STRAIGHT, STRAIN RELIEF BU-3964 1 BU-3964 1 5 GASKETS, ADHESIVE, 125X 375 [linear ft] GS-23622 1 GS-23622 1 6 INSULATION IN-2003 1 IN-2003 1 7 REAR TRIM, SPOT 5014137 1 5014204 1 8 RIVET, BLIND, #44, STNLS RI-2100 6 RI-2100 6 9 SWITCH COVER 11133 1 11133 1 10 SIDE PANEL 1011871 2 1011619 2 11 CONNECTOR-5 CONDUCTOR CR-34646 2 CR-34646 2 12 CASTER, 1 5" STEM, RIGID 5" CS-24874 2 CS-24874 2 13 CASTER, 1 5" STEM, 5" SWIVEL WITH BRAKE CS-24875 2 CS-24875 2 14 BOTTOM PANEL 1010394 1 1009941 1 15 DRIP TRAY KIT 5010391 1 5009716 1 - DRIP TRAY 1010584 1 1010189 1 - DRIP TRAY BRACKET 1010585 1 1010188 1 16 SCREW, 10-32 X 3/4", NF PHIL, FLAT M/S, 18-8 S/S SC-2072 6 SC-2072 6 17 HINGE, 1-3/8" OFFSET, PAIR, CHROME HG-22338 2 HG-22338 2 18 SCREW, 10-32 X 1-1/2", NF, PHIL,FLAT M/S,18-8 S/S SC-2073 10 SC-2073 6 19 DOOR ASSEMBLY, RH 5011828 1 5013154 1 DOOR ASSEMBLY, LH 5011829 1 5013155 1 DOOR GASKET GS-22951 1 GS-22952 1 20 SCREW, 10-32 X 3/4" PHILLIPS PAN HD SC-2071 2 SC-2071 2 21 HANDLE, OFFSET MAGNETIC LATCH HD-27080 1 HD-27080 1 22 SHI...

Эта инструкция также подходит к моделям:
Электрические печи - 1000-SK-I (2.63 mb)
Электрические печи - 1767-SK (2.63 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории