Войти:
Оценок - 3, средний балл: 4.7 ( )

Инструкция по эксплуатации Energizer, модель 715

Производитель: Energizer
Размер: 1.07 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


If your ratio value is outside the range, this the usual range of 5-50.* warning message will appear on the screen. ESC to correct, ACT to continue Press ESC to correct or ACT to continue. (* 0.3 - 3.0 for exch) To set just one ratio: To set more than one carb ratio: 6 The screen will return to the EDIT SETTINGS screen. Set your BG Units as described in the “BG (blood glucose) units” on page 69. 68 Chapter: 5 a. Press ESC. using grams using exchanges (flashing) (flashing) SET START TIME 2 _: _ grams __ /U __ __ SET START TIME 2 _: _ U/exch a. Set the start time for the next ratio and press ACT. b. Set the value for the next ratio and press ACT. c. Repeat steps a and b to set more ratios. d. Press ESC when you are done. using grams SET START TIME 2 _: _ __ grams /U (flashing) set then press ACT *Dependingon how many ratios you set, this number can be 2 through8. using exchanges __ __ SET START TIME 2 _: _ U/exch SET CARB RATIO 2* 7:00A grams __ /U __ __ SET EXCH RATIO 2* 7:00A U/exch EDIT SETTINGS Wizard: On Carb Units: grams Carb Ratios: - > BG (blood glucose) units You can select mg/dL or mmol/L as your BG units (unit of measurement type). NOTE -If you make changes to your BG units setting, you must reprogram your insulin sensitivity and BG targets. 7 In the EDIT SETTINGS 8 Select mg/dL or 9 The screen will return to the screen, select BG Units mmol/L and press ACT. EDIT SETTINGS screen to set and press ACT. EDIT SETTINGS Carb Units: grams BLOOD GLUCOSE UNITS mg/dL mmol/L your insulin sensitivity next. - - EDIT SETTINGS Sensitivity: Carb Ratios:- > - - BG Target: BG Units:- - - - Active Ins Time: Insulin sensitivity Your insulin sensitivity is the amount your blood glucose level is reduced by one unit of insulin. This value (amount) is used to calculate a suggested bolus insulin dose to correct your blood glucose level when it is above your target range. Correcting your blood glucose brings it down to your target range. Since insulin sensitivity amount can change throughout the day, your pump lets you enter up to eight (8) different insulin sensitivity settings. Your healthcare professional may have you enter only one or two insulin sensitivity settings when you first start using the Bolus Wizard feature. Record your settings in the “Bolus Wizard feature settings” table (see page 60). Insulin sensitivity amounts are normally between 20 – 100 mg/dL (or 1.1 – 5.6 mmol/L). If your amount is outside this range, a warning message will appear on the screen. 1 In the EDIT SETTINGS screen, select Sensitivity and press ACT. 2 Enter the amount for the first insulin sensitivity setting and press ACT. - -Sensitivity: (flashing) set, NOTE -The start time for your first insulin then press ACT sensitivity is midnight (12:00A) and cannot be changed. ACT EDIT SETTINGS Carb Ratios: ---> BG Units: mg/dL INS SENSITIVITY 1 12:00A mg/dLper unit insulin Using the Bolus Wizard feature 69 3 The SET START TIME 2 screen will appear. 4 To set just one insulin sensitivity: To set more than one insulin sensitivity: Press ESC. (flashing) SET START TIME 2 mg/dL per unit insulin _ _ __: _ a. Set the start time for the next insulin sensitivity and press ACT. b. Set the value for the next insulin sensitivity and press ACT. c. Repeat steps a and b to set more values. d. Press ESC when you are done. (flashing) set, then press ACT SET START TIME 2* 7:30A mg/dL per unit insulin _ _ _ (flashing) set, then press ACT * Depending on how many values you set, this number can be 2 through 8. INS SENSITIVITY 2* 7:30A mg/dL per unit insulin 50 5 The screen will return to the EDIT SETTINGS screen. You can now program your BG target(s). BG (blood glucose) target range The BG target range setting allows you to set your blood glucose target range. Because your target may vary throughout the day, your pump allows you to set up to eight (8) BG targets each day. If you want to set just one target value, instead of a range, set both the low and high values to the same number. If your current blood glucose level is above your BG target range, the Bolus Wizard feature will calculate a correction dose. If your current blood Correct up to the lower limit glucose level is below the BG target range, the Bolus (mg/dL) 70 Target Range Wizard feature will calculate a negative correction (mmol/L) 3.8 and subtract it from your food bolus. Correct down to upper limit(mg/dL) 100 (mmol/L) 5.5 Glucose Concentration 22.2 13.9 5.5 3.8 (mmol/L) 400 250 100 70 (mg/dL) 70 Chapter: 5 NOTE -Pumps are sent from the factory with a BG target range of 90-140 mg/dL (5.0-7.8 mmol/L). If you adjust your BG targets outside of 90-140 mg/dL (5.0-7.8 mmol/L), the pump screen displays a warning that the values are acceptable but outside the normal range. 1 In the EDIT SETTINGS screen, select BG first BG Target ACT TARGET RANGE 1 EDIT SETTINGS Range Target and press ACT. 12:00A BG Units: mg/dL (flashing) mg/dL - - -BG Target: Sensitivity: -> 2 Enter the low end of your BG target range 100 - 100 ...

Эта инструкция также подходит к моделям:
Измерители глюкозы - 515 (1.07 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории