Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации GE, модель TR5451

Производитель: GE
Размер: 167.79 kb
Название файла: a2e07304-0421-49f6-b7ac-8ccc2ec1d4cc.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


/ 22kAIC Max. TR451 Wiring Diagram 903-640-0555 800-950-2281 NOTE: If lamp is out, replace unit LISTED (48E6) UL 1449, 2ND EDITION FOR INDOOR USE ONLY DUAL PHASE TVSS 120 VAC 50/60HZ SUPPRESSION VOLTAGES 330 L-N 600 L-L TVSS PART# ACT452120210N DATE CODE: WO# Green Black Black White 30 A. / 22kAIC Max. NO COM NC Optional Alarm Terminal TR452 Wiring Diagram 3. The TVSS can be installed in any orientation, however special consideration should be given to allow periodic visual inspection of the status indicator lamps. CONNECTION 1. TR5451 and TR5452 Model TVSS units come equipped with 10 AWG connection wires to allow termination to the electrical system. It is important that the TVSS be installed in a location that is as close to the termination point as possible. Connection wires should be trimmed to prevent excessive lead length. Do not coil, loop or make sharp bends with the connection wires. Every inch of wire that can be trimmed away will aid the TVSS in it’s ability to provide the best possible protection level for your system. 2. Refer to the wiring diagrams on the left for your selected model type. The TR5451 and TR5452 models must be connected to a branch circuit breaker. The breaker must not exceed a 30A / 22kAIC rating. 3. Remote Alarm Relay Contacts are provided as an optional feature on some model types. Contacts are standard 1 Form C type, rated 5 A, 250 VAC max. Refer to the wiring diagram on the left for contact configuration. The relay contact will be closed between “NO” and “COM” under normal operation. If the TVSS fails, or if power is lost to the TVSS, the relay contact will open between “NO” and “COM” and close between “NC” and “COM”. 4. Model types with 210N and 210S part number suffixes are fitted with jumpers on the alarm terminal block which connects the “COM” and “NC” contacts to the ground terminal of the TVSS. This feature should only be utilized for OEM installations where this type of configuration has been evaluated as suitable. For all other installations, the jumpers should be removed so that the alarm contacts will function normally per paragraph 3 above. OPERATION 1. When energized, the green LED status indicator lamps located on the front of the TVSS will be illuminated. For TR5451 models, there is 1 indicator. For TR5452 models, there are 2. 2. If one or both of the of the status indicators are not illuminated, verify the integrity of the connection terminations, breaker status, the electrical supply voltage and the electrical system grounding. 3. If no problems are found, the TVSS could be in failure mode and require replacement. Contact your local GE representative for further assistance. MAINTENANCE 1. TR5451 and TR5452 model types contain no user serviceable parts and require no annual maintenance or calibration. Only a periodic visual inspection of the LED indicators is required. Do not attempt to repair or otherwise alter the TVSS unit. 2020003701 (08/06) Page 3 of 4 DIMENSIONS: 4.54 NO COM NC 2.29 STANDARD MODEL 903-640-0555 800-950-2281 NOTE: If lamp is out, replace unit LISTED (48E6) UL 1449, 2ND EDITION FOR INDOOR USE ONLY DUAL PHASE TVSS 120 VAC 50/60HZ SUPPRESSION VOLTAGES 330 L-N 600 L-L TVSS PART# ACT452120210N DATE CODE: WO# 2.85 0.56 903-640-0555 800-950-2281 LISTED (48E6) UL 1449, 2ND EDITION FOR INDOOR USE ONLY NOTE: If lamp is out, replace unit DUAL PHASE TVSS 120 VAC 50/60HZ SUPPRESSION VOLTAGES 330 L-N 600 L-L TVSS PART# ACT452120210N DATE CODE: WO# 5.28 4.63 2.85 210N / 210S MODEL TYPE g GENERAL SPECIFICATIONS: Max. Surge Rating 40kA /Phase TVSS Type One Port / Parallel Connected Connection Method 10 AWG Conductors Operating Frequency 50Hz – 60Hz Operating Temperature -40o C to +70o C Installation Location Indoor / NEMA 1 Status Indication Green LED Lamps / 1 per phase Fusing Thermally Protected MOV’s Circuit Breaker Required, 30A / 22kAIC Max. Rating Regulatory UL, cUL, CE CERTIFICATE OF COMPLIANCE: GE Zenith Controls hereby certifies that all TVSS products are manufactured in accordance with the applicable drawing, specification and purchase order requirements in compliance with the ISO 9001 Standard. Manufacturing Level Tests are performed on 100% of all units shipped. Verification Level Tests were also conducted on each product family as part of the design verification process and was used to demonstrate that GE Zenith has achieved the published design specifications . A certificate of compliance is available upon request. NOTICE: These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser's purposes, the matter should be referred to the GE Company. GE DIGITAL ENERGY – GE Zenith Controls – 2501 Pecan Street – BONHAM, TEXAS 75418 USA 2020003701 (08/06) Page 4 of 4 ...

Эта инструкция также подходит к моделям:
Источники питания и БП - TR5452 (167.79 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории