Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Alpha Industries, модель 2000

Производитель: Alpha Industries
Размер: 1023.25 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


2.2 Wiring the Unit Procedure: 1 Connect the load(s) to the unit.s output connector(s) (Figure 2.1). 2 Connect RS.232 or other communications, emergency power off switch, battery packs or any other options (Sections 2.3 to 2.6). 3 Connect the line to the unit.s input connector. TIP: Determine what output voltage you are using. When starting the unit for the first time, see if you need to configure the unit.s output voltage (Section 3.4). Wiring Finished Turn on the unit as described in Section 3.1. Alpha Technologies 11 2 Installation Alpha Technologies Line In To Loads 2.2 Wiring the Unit (Continued) To Loads From Line Figure 2.1 Input/Output Wiring 2.3 Connecting External Battery Packs Up to 2 external battery packs can be connected. Place them next to the unit. Procedure: 1 Turn off the unit (Section 3.1). 2 Disconnect the unit from the line and the load(s). 3 Connect the cable from the battery pack to the unit (Figure 2.2). If used, connect the second battery pack to the first pack. 4 Connect the loads to the unit. 5 Connect the line to the unit. 6 Turn on the unit (Section 3.1). Battery Pack Connection Finished 2 Installation 12 Alpha Technologies 2.3 Connecting an External Battery Pack (Continued) 2.4 Connecting an Emergency Power Off Switch An Emergency Power Off (EPO) switch is connected to the rear panel.s EPO connector. When this switch is opened, the unit shuts off. To restart the unit, turn it on (Section 3.1). Figure 2.3 Emergency Power Off Switch Wiring Normally Closed Switch EPO Connector Figure 2.2 External Battery Pack Connection 13 2 Installation Alpha Technologies 2.5 Connecting the RS-232 Port With the Alphamon software, you can remotely control the unit with RS-232 communications. It supports Windows 95/98/ME/2000/NT/XP, Novell NetWare or Linux. The CD that came with the unit contains installation instructions. Only use the connection cable that came with the unit. TIP: If the optional USB port is used, the RS-232 port is automatically disabled. 4 3 2 1 9 8 7 6 5 TxD RxD Common DCD CTS RI Pin # Signal Name Function 2 TxD TxD Output 3 RxD RxD / Inverter Off Input 5 Common 6 CTS AC Fail Output 8 DCD Low Battery Output 9 RI +8--24 VDC Power Figure 2.4 DB.9 Port Pin Out 2.6 Network Connection The rear panel.s Network Transient Protector allows the unit to be connected to a network. It uses a single RJ-45 (10BaseT) network card. Plug the input connector to the .IN. connector and the output connector to the .OUT. connector. Two communication cards can be installed. The SNMP card allows control and management over a network or the internet. The AS/400 card allows voltage free relay contacts. Contact Alpha Technologies for more information and availability. Network Transient Protector SNMP or AS/400 card Figure 2.5 Network Connections 14 Section 3 Operation This section tells you how to operate the Pinnacle Plus series. • How to turn the unit on and off (Section 3.1). • How to use the control panel (Section 3.2). • How to perform a self test (Section 3.3). • How to change the unit.s parameters (Section 3.4). • How to troubleshoot the unit (Section 3.5). • How to replace the batteries (Section 3.6). 15 3 Operation 3.1 Turning the Unit On and Off Turn On: Before turning the unit on for the first time, determine what output voltage you need. If needed, change the unit’s output voltage parameter (Section 3.4) before turning on the load. 1 Press down the ON/OFF button until “Ready On” appears on the LCD. The fan turns on. The LCD shows “Ready On” while it conducts a self test. The ON LED turns on. If line power is sent to the loads, the ONLINE LED turns on. If battery power is sent to the loads, the ON-BATT LED turns on. TIPS: 1) A brand new unit needs to charge the batteries before the maximum run time is reached. This takes about 24 hours after the unit is turned on. 2) If you are changing the unit’s parameters (Section 3.4), change them before turning on the loads. ON-LINEON ON-BATT BYPASS FAULT ON/OFFFUNC ENTER Line Mode 2 Turn on the loads. Turn Off: 1 Turn off the loads. 2 Press down the ON/OFF button for five seconds. The LCD shows “Shutdown” then “UPS Off” then becomes dark. The fan and the ON LED turns off. ON-LINEON ON-BATT BYPASS FAULT FUNC ENTER ON/OFF UPS Off For emergency shutdowns, install an Emergency Power Off switch (Section 2.4). Alpha Technologies 3 Operation 16 3.2 Using the Control Panel LEDs: • ON: The unit is on. • ON-LINE: Line power is provided to the loads. • ON-BATT: Backup battery power is provided to the loads. • BYPASS: Line power is provided to the loads via the unit’s bypass circuit. • FAULT: The unit has a fault. Do troubleshooting (Section 3.5). Press any push button to turn off the alarm. Push Buttons: • ON/OFF: This turns the unit on and off. • ENTER: This sets the parameter you have selected. • FUNC: This scrolls through the menus. If no action is taken in 10 seconds, the LCD returns to its original status. Meter Display: Measurements are made with the display p...

Эта инструкция также подходит к моделям:
Источники питания и БП - 1000 (1023.25 kb)
Источники питания и БП - 1500 (1023.25 kb)
Источники питания и БП - 3000 (1023.25 kb)
Источники питания и БП - 700 (1023.25 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории