Войти:
Оценок - 3, средний балл: 5 ( )

Инструкция по эксплуатации American Power Conversion, модель 2200XLT

Производитель: American Power Conversion
Размер: 861.88 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Note: Please read the cautions in the Safety section at the beginning of this User’s Manual. Once the battery is disconnected, the loads are not protected from power outages. Model Number Replacement Battery Cartridge (RBC) # SU1400XLTNET RBC 11 SU2200XLTNET RBC 11 SU3000TNET RBC 11 SU5000T RBC 12 SU1400RMXLTNET RBC 11 SU2200RMXLTNET RBC 11 SU3000RMT3U RBC 12 SU5000RMT5U RBC 12 11 990-7031C, Revision 4 12/99 990-7031C, Revision 4 12/99 12 Battery Replacement Procedure - Tower Units 5000 VA 1. Grasp the top edge of the bottom front cover and tilt it out. For the 5000 VA unit: Remove the front bezel by grasping the finger clips on the side of the bezel and carefully loosening the four (4) snaps. Skip to step 3. 1400-3000 VA 5000 VA 2. Unhook the bottom section of the front cover from the chassis and set it aside. 3. Use a screwdriver or a coin to remove the two (2) battery door screws and open the door. 4. Disconnect the front battery pack: For the 1400 – 3000 VA models, gently but firmly pull the red and black wires at the top of the battery housing to disconnect the gray connector plug from the UPS. For the 5000 VA model, grip the white cord on the front set of batteries and pull firmly to disconnect the connector. 5. Pull the front battery out of the UPS by pulling on the clear label, not the white cord. Remove the foam spacer and set it aside. (The 5000 VA unit does not use foam spacers.) Notes: Be careful removing the batteries - they are heavy. Support the bottom of the batteries as you remove them. The 5000 VA model has four of batteries, two in each compartment. Exercise special care when removing the top set. 1400-3000 VA 5000 VA 6. Disconnect and remove the second battery pack by repeating steps 4 and 5. 7. Replace the back battery (or set). For 5000 VA units: Hold the battery pack so that the leads are on top. Slide the battery pack into the UPS. 8. Reconnect the battery (or set.) For 1400 – 3000 VA units: Press the gray connector into the plug at the top of the battery housing. Replace the foam spacer (if used). Replace the front battery (or set) into the UPS and reconnect. For 5000 VA units: Press the gray connector into the plug at the top of the battery compartment. Tuck the white cord (that serves as a handle for the connector) neatly to the side. Notes: For the 5000 VA model, repeat steps 4 through 8 for the second set of battery packs. Small sparks at the battery connectors are normal during connection. 9. Close the battery door, replace the screws, and replace the lower front cover or bezel. Batteries must be recycled. Deliver the battery to an appropriate recycling facility or ship it to the supplier in the new battery’s packing material. See the new battery instructions for more information. 13 990-7031C, Revision 4 12/99 Battery Replacement Procedure - 3U Rack Mount Units 1. Reach into the finger pull and open the front cover. Swing the cover open as shown. 2. Unhook the side of the cover from the chassis and lift it away to expose the battery door. 3. Use a flat-blade or Phillips screwdriver or a coin to remove the two battery door screws and open the door. 4. Grasp the tab and gently pull the battery out of the UPS. 5. Disconnect the battery leads. Loosen the connectors by gently wiggling them while pulling straight back from the battery connector. 6. Connect the battery leads to the new battery. Connect the red wire to the positive (+) terminal and the black wire to the negative (–) terminal. 7. Slide the battery into the UPS. 8. Close the battery door, replace the battery compartment screws, and replace the front cover. Notes: Be careful removing the batteries - they are heavy. Small sparks at the battery connectors are normal during connection. Batteries must be recycled. Deliver the battery to an appropriate recycling facility or ship it to the supplier in the new battery’s packing material. See the new battery instructions for more information. 990-7031C, Revision 4 12/99 14 Battery Replacement Procedure - 5U Rack Mount Units 5000 VA 1. Reach into the finger pull and open the front cover. Swing the cover open as shown. For 5000 VA units: Remove the front bezel by grasping the finger clips on the side of the bezel and carefully loosening the four (4) snaps. Skip to step 3. 2. Unhook the side of the cover from the chassis and lift it away to expose the battery door. 5000 VA 1400 VA 5000 VA 3. Use a screwdriver or a coin to remove the two (2) battery door screws and open the door. 4. Disconnect the front battery pack: For the 1400 – 3000 VA models, gently but firmly pull the red and black wires at the top of the battery housing to disconnect the gray connector plug from the UPS. For the 5000 VA model, grip the white cord on the front set of batteries and pull firmly to disconnect the connector. 5. Pull the front battery out of the UPS by pulling on the clear label, not the white cord. Remove the foam spacer and set it aside. (The 5000 VA unit does not use foam spacers.) Notes: Be car...

Эта инструкция также подходит к моделям:
Источники питания и БП - 1400XLT (861.88 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории