Войти:
Оценок - 5, средний балл: 4 ( )

Инструкция по эксплуатации ADC, модель 1000

Производитель: ADC
Размер: 705.27 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Do not assume laser power is turned off or the fiber is disconnected at the other end. Caution: Ethernet signals over copper should not be used between buildings. Ground potential differences may cause transmission errors or line card failures. 20460-A RJ45 CONNECTOR OPTICAL TRANSMIT OPTICAL RECEIVE ADCP-92-063 • Issue 1 • May 2005 b. The IEEE Standard ANSI/TIA-568-B for Ethernet 10/100BaseT(X) requires that two twisted pairs be used and that one pair is connected to pins 1 and 2, and that the second pair is connected to pins 3 and 6. c. The IEEE Specification Standard ANSI/TIA-568-B for Ethernet 1000BaseT requires that four twisted pairs are used. One pair is connected to pins 1 and 2, pair two is connected to pins 3 and 6, pair three is connected to pins 4 and 5, and pair four is connected to pins 7 and 8. 9. Connect Ethernet RJ45 patchcord to RJ45 receptacle on the converter module. 10. Verify that the front panel LEDs are active. Link LEDs are not lighted if there is no Ethernet or optical signal present. PIN 1 PIN 8 11899-A Figure 5. RJ45 Connector Wiring Table 4. 10/100BaseT(X) Ethernet RJ45 Connector RJ-JACK PIN # SIGNAL NAME FUNCTION PIN # SIGNAL NAME FUNCTION 1 TX+ Transmit Data 2 TX– Transmit Data 3 RX+ Receive Data 4 --Not used 5 --Not used 6 RX– Receive Data 7 --Not used 8 --Not used Table 5. 1000BaseT Ethernet RJ45 Connector PIN # SIGNAL NAME FUNCTION PIN # SIGNAL NAME FUNCTION 1 BD1+ Bidirectional 2 BD1– Bidirectional 3 BD2+ Bidirectional 4 BD3+ Bidirectional 5 BD3– Bidirectional 6 BD2– Bidirectional 7 BD4+ Bidirectional 8 BD4– Bidirectional Page 9 © 2005, ADC Telecommunications, Inc. ADCP-92-063 • Issue 1 • May 2005 4 SPECIFICATIONS Table 6 and Table 7 lists the specifications for the module. Table 6. Electrical and Mechanical Specifications PARAMETER SPECIFICATION REMARKS Electrical Input Voltage +5 VDC Backplane connector Input power (10/100 Mb/s) 1.75 W max. Normal operation Input power (1000 Mb/s) 2.2 W max. Normal operation Mechanical Chassis Compatibility OptEnet Media Converter All modular systems Module Retention Captive thumbscrews Dimensions (H.W.D) 1.14 in.. 8.07 in.. 7.4 in. (2.89 cm . 20.5 cm . 18.8 cm) Weight 0.27 lb. (122 g.) Electrical Signal Interface RJ45 Two twisted pair 10/100 Mb/s RJ45 Four twisted pair 1000 Mb/s Optical Signal Interface LC Singlemode 1410 – 1610 nm * * -Refer to the OptEnet SFP Transceiver Specifications listed in Related Publications, for optical specifications. Table 7. Module Environmental Specifications PARAMETER SPECIFICATION REMARKS Operating Conditions 41°F to +104°F (5°C to +40°C) Per Telcordia GR-63 Short Term Conditions +23°F to +122°F (.5°C to +50°C) Per Telcordia GR-63 Storage Conditions .40°F to +185°F (.40°C to +85°C) at 5% to 95% RH Non-condensing 5 POWER-UP/CHECK OUT PROCEDURE Media Converter Modules are powered up as soon as power is applied to the chassis. The POWER indicator (GREEN LED) on the converter module should light to indicate that VDC power is applied to the media converter. If POWER indicator does not come on, verify that power connections between the Media Converter Module and the power supply are secure. Verify that there is power present at the source. If this procedure does not resolve the problem, replace the cable or power supply. Page 10 © 2005, ADC Telecommunications, Inc. ADCP-92-063 • Issue 1 • May 2005 OptEnet Media Converter with SFP modules support Medium Dependent Interface Crossover (MDI-X). OptEnet Media Converter Module Ethernet ports allow connections to other hubs or switches without a null-modem or crossover cable. If a null-modem or crossover cable has been used the OptEnet Media Converter with SFP module automatically detects this and switches the contacts to match the other end. Any blinking of a link LED indicates auto-negotiation in process. If a link LED continues to blink for more than 30 seconds then the operation of the far end device (i.e., duplex and speed) needs to be verified or changed. 5.1 10/100 Mb/s Module If the PC workstation port has been set to auto-select (i.e., full auto-negotiation) for speed and duplex, the TPLink LED will be OFF when power is applied unless a valid optical link has already been established with a remote optical port. If a valid optical link has been established, FOLink LED will be YELLOW for 10 Mb/s operation or GREEN for 100 Mb/s operation. The preferred mode of operation for the port is auto select for both speed and duplex. This will insure that a link can be established regardless of the far end operational mode. OptEnet 10/100BaseLX Media Converters support auto-negotiation as defined in TIA/EIA-785. Auto-negotiation allows the unit to automatically select the highest performance level for COPPER or FIBER. 5.2 1000 Mb/s Module Set data rate speed to 1000 Mb/s and enable half/full duplex auto-negotiate on any equipment connected to the OptEnet 1000 Mb/s Media Converter module. If the Network Interface Card (NIC) or port in the PC workstation has been set to 10...

Эта инструкция также подходит к моделям:
Источники питания и БП - 10 (705.27 kb)
Источники питания и БП - 100 (705.27 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории