Инструкция по эксплуатации APC, модель 3000

Производитель: APC
Размер: 277 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Low Battery 120 sec Set the value in The UPS will emit an audible alarm when the Warning seconds remaining runtime has reached this level. Date of Last Date set at factory Reset this date when the battery module is replaced. Battery Replacement Audible Alarm On On/Off The UPS will mute all audible alarms if this is set to Off or when the display buttons are pressed. Battery Self-On start-up and • Never The interval at which the UPS will execute a Test Interval every 14 days since • Start-up only self-test. Setting the last test • Frequency of test (days) Reset to Factory No Yes/No Restore the UPS factory default settings. Default Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Main Outlet Group and the Switched Outlet Group Overview The Main Outlet Group and the Switched Outlet Group can be configured to independently turn off, turn on, shut down, and reboot connected equipment. (These features are not available on the 750 VA units.) The Main Outlet Group and the Switched Outlet Group can be commanded to do the following: • Turn off: Disconnect from power immediately and restart only with a manual command • Turn on: Connect to power immediately • Shutdown: Disconnect power in sequence, and automatically reapply power in sequence when utility power becomes available • Reboot: Shut down and restart In addition, the Main Outlet Group and the Switched Outlet Group can be configured to do the following: • Turn on or off in a specified sequence • Automatically turn off or shut down when various conditions occur Note: If the Main Outlet Group and the Switched Outlet Group are not configured, all of the outlets on the unit will still provide battery back-up power. Using the Main Outlet Group and the Switched Outlet Group The Main Outlet Group functions as a master switch. It will turn on first when power is applied, and shut off last when there is a power outage and battery run-time has been exhausted. The Main Outlet Group must be turned on for the Switched Outlet Group to turn on. 1. Connect critical equipment to the Main Outlet Group. 2. Connect peripheral equipment to the Switched Outlet Group. – Nonessential equipment that should shut off quickly in the event of a power outage to conserve battery runtime can be added to a short power-off delay – If equipment has dependent peripherals that must restart or shut down in a specific order, such as an ethernet switch that must restart before a connected server, connect the devices to separate groups – Equipment that needs to reboot independently from other equipment should be added to a separate group 3. Use the Configuration menus to configure how the Switched Outlet Group will react in the event of a power outage. Customize the Main Outlet Group and the Switched Outlet Group Use the Control menus to change the Switched Outlet Group and the Main Outlet Group settings. Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Function Factory Default Options Description Name String Outlet Group 1 Edit these names using an external interface, such as the Network Outlet Group Management Card Web interface. UPS Name String UPS Outlets Turn On Delay 0 sec Set the value in The amount of time the UPS or Switched Outlet seconds Group will wait between receiving the command to turn on and the actual startup. Turn Off Delay 0 sec Set the value in The amount of time that the UPS or Switched seconds Outlet Group will wait between receiving the command to turn off and the actual shut down. Reboot Duration 4 sec Set the value in The amount of time that the UPS or Switched seconds Outlet Group must remain off before it will restart. Minimum Return 0 sec Set the value in The amount of battery runtime that must be Time seconds available before the UPS or Switched Outlet Group will turn on. Load Shed On Disabled • Shutdown with When the unit switches to battery power, the UPS Battery Delay can disconnect power to the Switched Outlet • Shutdown Group to save runtime. immediately Configure this delay time, use the LOAD SHED • Turn off TIME WHEN ON BATTERY setting. immediately • Turn off with delay • Disabled Load Shed Time Disabled Set the value in The amount of time the outlets will function on when On Battery seconds battery power before they will turn off. Load Shed On Disabled • Shutdown with When the battery runtime falls below the Runtime delay specified value, the Switched Outlet Group will • Shutdown turn off. immediately Configure this time using the LOAD SHED • Turn off RUNTIME REMAINING setting. immediately • Turn off with delay • Disabled Load Shed On Disabled Set the value in When the remaining runtime reaches this level, Runtime seconds the Switched Outlet Group will turn off. Remaining Load Shed on Disabled • Disabled In the event of an overload (greater than 100% Overload •Enabled output), the Switched Outlet Group will immediately turn off to conserve power for critical loads. The Switched Outlet Group will only turn on again with a manual command. Network Managem...

Эта инструкция также подходит к моделям:
Источники питания и БП - 1000 (277 kb)
Источники питания и БП - 750 (277 kb)
Источники питания и БП - 2200 (277 kb)
Источники питания и БП - 1500 (277 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории