Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации GE, модель DSXH47GG

Производитель: GE
Размер: 137.47 kb
Название файла: 353d91f9-0c3d-48f8-92bb-bbe08807f3ec.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Extra-Large Capacity Frontload Gas Dryer Exhaust Options: 3-way via rear, left, and bottom. Circuit Requirements: An individual, properly grounded branch circuit, protected by a 30-amp circuit breaker or a time-delay fuse, is required. Note: Dryer wall outlet must be located within 36” of service cord entry and accessible when dryer is mounted in position. Installation Information: For complete information, see installation instructions packed with your dryer. Door Open 90° SIDE VIEW 27 4-3/4 5 36 Under Counter 36 Electric Connection 13-9/16 3/16" 2-1/4 Gas Pipe Connection For answers to your Monogram,® GE Profile™ or REAR VIEW GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. Specification Revised 5/09 360471 DSXH47GG GE® 5.8 Cu. Ft. Extra-Large Capacity Frontload Gas Dryer Special Installation Requirements: Stacked Installation: • Brackets for stacking dryer are included as part of the dryer, DSXH43EF/GF. See dryer Use & Care for details. • Bracket for stacking dryer, DSXH47EG/GG, order Pub. No. 14-A026 or STACKIT1WW at additional cost. Undercounter installation: • The WSSH300G and DSXH47EG/GG require a custom-sized countertop (36 inches to the underside of the countertop). No special washer or dryer top is required. Alcove or Closet Installation: • If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. • The dryer MUST be exhausted to the outside. • Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side, 3" front and rear • Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52". • Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • No other fuel-burning appliance shall be installed in the same closet with a gas dryer. Bathroom or Bedroom Installation: • The dryer MUST be exhausted to the outdoors. • The installation must conform with the local codes, or in the absence of local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers. Minimum Clearance other than Alcove or Closet Installations: • Minimum clearances to combustible surfaces 0" both sides, 3" rear. For more information on venting kits and accessories, please call 1-800-GE-CARES. For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. Specification Revised 5/09 360471 DSXH47GG GE® 5.8 Cu. Ft. Extra-Large Capacity Frontload Gas Dryer Dryer Exhausting Information – Metal Duct Only For complete information, see installation instructions packed with your dryer. Ducting Materials: For best performance, this dryer should be vented with 4” diameter all rigid metal exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit WX08X10077). In special installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid B metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4” diameter can be maintained throughout the entire length of the transition duct. Please see installation Domestic A4A2-1/2 instruction packed with your dryer for complete instructions when using flexible metal (foil dryer models type) ducting. Exhaust Length Calculation: 7.0, 6.0 and 5.8 cu. ft. 1. Determine the number of 90° turns needed for your installation. If you exhaust to the capacity models side or bottom of dryer, add one turn. all gas dryers 2. The maximum length of 4’ rigid (aluminum or galvanized) duct which can be tolerated is shown in the table. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow. Dryers must be exhausted to the outside. Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down. For more information on venting kits and accessories, please call 1-800-GE-CARES. Number of 90° turns 0 1 2 3 Best performance Maximum length of 4" dia. rigid metal duct Exhaust hood type A 4" opening 90 ft. 60 ft. 45 ft. 35 ft. B 2-1/2" ope...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории