Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Humminbird, модель 531427-1_D

Производитель: Humminbird
Размер: 1.68 mb
Название файла: M_531427-1_D.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Three different fish size icons represent the intensity of the sonar return, and provide an indicator of relative fish size. DualBeam PLUSTM Sonar models represent targets detected in the 200 kHz narrow beam as Shaded Fish Symbols, and represent targets detected in the 83 kHz wide beam as Hollow Fish Symbols. 200 kHz, Narrow Beam 83 kHz, Wide Beam Shaded Fish Symbols Hollow Fish Symbols When Fish ID+TM is turned off, the 700 Series™ Fishing System shows only the raw sonar returns on the display. These returns will often result in "arches" forming on the display, indicating potential targets. Due to the transducer beam angle, the distance to a fish decreases as the fish moves into the beam, and then increases as it moves out again, creating a Fish Arch when this distance change is shown on the display. Boat speed, chart speed, and the position of the fish within the sonar beam greatly affect the shape of the arch. Transducer Cone and Fish Arches To turn Fish ID+™ on or off: 1. Highlight Fish ID+ on the Sonar main menu. 2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to turn the Fish ID+TM setting On or Off. (Off, On, Default = Off) 56 Fish ID Sensitivity Fish ID Sensitivity adjusts the threshold of the Fish ID+TM detection algorithms. Selecting a higher setting allows weaker returns to be displayed as fish. This is useful for identifying smaller fish species or baitfish. Selecting a lower setting displays fewer fish from weak sonar returns. This is helpful when seeking larger species of fish. Fish ID Sensitivity is used in conjunction with Fish ID+TM. Fish ID+TM must be On for Fish ID Sensitivity to affect the ability of the 700 Series™ Fishing System to identify sonar returns as fish. To change the Fish ID Sensitivity setting: 1. Highlight Fish ID Sensitivity on the Sonar main menu. 2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Fish ID Sensitivity setting. (Low = 1, High = 10, Default = 5) Real Time Sonar (RTS®) Window RTS® Window sets the RTS® Window to either Wide or Narrow, or turns it off in the Sonar View. The RTS® Window always updates at the fastest rate possible and only displays returns that are within the transducer beam. (See Real Time Sonar (RTS®) Window for more information.) RTS® Window (Wide) RTS® Window (Narrow) RTS® Window (Off) To change the RTS® Window setting: 1. Highlight RTS Window on the Sonar main menu. 2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the RTS® Window setting. (Wide, Narrow, Off, Default = Wide) 57 Zoom Width Zoom Width adjusts the width of the Zoom window on the Sonar Zoom View. To change the Zoom Width Setting: 1. Highlight Zoom Width on the Sonar main menu. 2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Zoom Width setting. (Narrow, Medium, Wide, Default = Wide) 83 kHz Sensitivity (Advanced) 83 kHz Sensitivity changes the sensitivity of the 83 kHz beam. Increasing the 83 kHz Sensitivity will display additional weak returns and decreasing the 83 kHz Sensitivity will display fewer weak returns. The 83 kHz Sensitivity menu choice is only available when User Mode is set to Advanced (see Setup Menu Tab: User Mode). NOTE: 83 kHz Sensitivity is particularly useful for adjusting the sensitivity of the 83 kHz sonar returns in the 200/83 kHz Split Sonar View. The 83 kHz sensitivity can be adjusted without affecting the sensitivity of the 200 kHz returns shown in the 200 kHz sonar window. To set the 83 kHz Sensitivity: 1. Make sure you are in Advanced User Mode, then highlight 83 kHz Sensitivity on the Sonar main menu. 2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to set the 83 kHz Sensitivity. (-10 to +10, Default = 0) 455 kHz Balance (Advanced, with QuadraBeam™ Transducer) 455 kHz Balance adjusts the sensitivity of the 455 kHz beam. Increasing the sensitivity will display additional weak returns and decreasing the sensitivity will display fewer weak returns. A QuadraBeam™ transducer must be attached to the 700 Series™ Fishing System. The 455 kHz Balance menu choice is available when Transducer Select is set to QuadraBeam™ (see Sonar Menu Tab: Transducer Select) and User Mode is set to Advanced (see Setup Menu Tab: User Mode). NOTE: The 455 kHz Balance requires the purchase of the QuadraBeam™ transducer. You can visit our website at to order this accessory online or contact our Customer Resource Center at 1-800-633-1468. 58 NOTE: 455 kHz Balance is particularly useful for adjusting the sensitivity of the 455 kHz sonar returns in the Side Beam View. The 455 kHz sensitivity can be adjusted without affecting the sensitivity of the 200 kHz returns shown in the 200 kHz sonar window. To change the 455 kHz Balance setting: 1. Make sure you have selected QuadraBeamTM Transducer and Advanced Mode, then highlight 455kHz Balance on the Sonar Main Menu. 2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the 455 kHz Balance. (-10 to +10, Default = 0) WideSide® Sensitivity (Advanced: with WideSide® transd...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории