Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Modine Manufacturing, модель GAS-FIRED HEATERS BD

Производитель: Modine Manufacturing
Размер: 3 mb
Название файла: e1166b81-7b42-4739-a092-dcc87142c63b.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Read the installation, operating and maintenance instructions throroughly before installing or servicing this equipment. All models approved for use in California by the CEC (when equipped with IPI), in New York by the MEA division, and in Massachusetts. Unit heater is certified for non-residential applications. Inspection on Arrival 1. Inspect unit upon arrival. In case of damage, report immediately to transportation company and your local Modine sales representative. 2. Check rating plate on unit to verify that power supply meets available electric power at the point of installation. 3. Inspect unit received for conformance with description of product ordered (including specifications where applicable). FOR YOUR SAFETY IF YOU SMELL GAS: 1. Open windows. 2. Don’t touch electrical switches. 3. Extinguish any open flame. 4. Immediately CAUTION call your gas supplier. To prevent premature heat exchanger failure do not locate ANY gas-fired units in areas where chlorinated, halogenated, or acid vapors are present in the atmosphere. IMPORTANT The use of this manual is specifically intended for a qualified installation and service agency. A qualified installation and service agency must perform all installation and service of these appliances. FOR YOUR SAFETY The use and storage of gasoline or other flammable vapors and liquids in open containers in the vicinity of this appliance is hazardous. THIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB. Heater Parts from ACF Greenhouses 2 THE INSTALLATION AND MAINTENANCE INSTRUCTIONS IN THIS MANUAL MUST BE FOLLOWED TO PROVIDE SAFE, EFFICIENT AND TROUBLE-FREE OPERATION. IN ADDITION, PARTICULAR CARE MUST BE EXERCISED REGARDING THE SPECIAL PRECAUTIONS LISTED BELOW. FAILURE TO PROPERLY ADDRESS THESE CRITICAL AREAS COULD RESULT IN PROPERTY DAMAGE OR LOSS, PERSONAL INJURY, OR DEATH. 1. Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage. All units must be wired strictly in accordance with wiring diagram furnished with the unit. 2. Turn off all gas before installing unit heaters. 3. Gas pressure to unit heater controls must never exceed 14”W.C. (1/2 psi). When leak testing the gas supply piping system, the unit and its combination gas control must be isolated during any pressure testing in excess of 14" W.C. (1/2 psi). The unit should be isolated from the gas supply piping system by closing its field installed manual shut-off valve during any pressure testing of the gas supply piping system. 4. Check gas inlet pressure at unit upstream from the combination gas control. The inlet pressure should be 6”-7”W.C. on natural gas or 12”-14”W.C. on propane gas. Purging of gas piping should be performed as described in ANSI Z223.1 Latest Edition, or in Canada in CAN/CGA-B149 codes. 5. All units must be vented to the outside atmosphere. 6. Do not install in potentially explosive or flammable atmospheres laden with grain dust, sawdust, or similar air-borne materials. In such applications a blower type heater installed in a separate room with ducting, including appropriate back flow prevention dampers, to the dust-laden room is recommended. 7. Installation of units in high humidity or salt water atmospheres will cause accelerated corrosion resulting in a reduction of the normal life span of the units. 8. To prevent premature heat exchanger failure do not locate ANY gasfired unit in areas where chlorinated, halogenated or acid vapors are present in the atmosphere. 9. Avoid installing units in extremely drafty locations. Drafts can cause burner flames to impinge on heat exchangers which shortens life. Maintain separation between units so discharge from one unit will not be directed into the inlet of another. 10. Do not locate units in tightly sealed rooms or small compartments without provision for adequate combustion air and venting. Combustion air must have access to the confined space through a minimum of two permanent openings in the enclosure, at least one near the bottom. They should provide a free area of one square inch per 1000 BTU per hour input rating of the unit with a minimum of 100 square inches for each opening, whichever is greater. 11. Do not install unit outdoors. 12. For all sizes, minimum clearance to combustibles from the bottom is 12" and from the sides 18"; for PD sizes 30-50 from the top is 1" and from the flue collar 2"; for PD sizes 75-300 from the top is 2" and from the flue collar is 3"; for PD 350 from the top is 3" and from the flue collar is 4"; for PD 400 from the top is 4" and from the flue collar is 5"; and for all BD sizes from the top and flue collar is 6...

Эта инструкция также подходит к моделям:
Газовые нагреватели - GAS-FIRED HEATERS BD (3 mb)
Газовые нагреватели - GAS-FIRED HEATERS BD (3 mb)
Газовые нагреватели - GAS-FIRED HEATERS BD (3 mb)
Газовые нагреватели - GAS-FIRED HEATERS PD (3 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории