Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Desa, модель GWP10T

Производитель: Desa
Размер: 3.17 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Wait one (1) minute before lighting pilot again. 8. Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO. CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve. Ignitor ElectrodeIgnitor Button Control Knob PILOTLO OFFHI IGNITOR Figure 22 - Control Knob In The OFF Position Pilot BurnerThermocouple Figure 23 - Pilot TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. Turn control knob clockwise to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed. Shutting Off Burner Only (pilot stays lit) Turn control knob clockwise to the PILOT position. THERMOSTAT CONTROL OPERATION The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO. Note:The thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size, open air temperatures, etc.). Frequent use of your heater will let you determine your own comfort levels. MANUAL LIGHTING PROCEDURE 1. Remove front panel (see Figure 10, page 8). 2. Follow steps 1 through 5 under Lighting Instructions. 3. With control knob pressed in, strike match. Hold match to pilot until pilot lights. 4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Follow step 8 under Lighting Instructions. 5. Replace front panel. For more information, visit more information, visit 107902-01D INSPECTING BURNER Pilot Flame Pattern Burner Flame Pattern Blue Flame Models Burner Flame Pattern Infrared Models 15 INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 24 shows a correct pilot flame pattern. Figure 25 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 25 • turn heater off (see To Turn Off Gas to Appliance, pages 12, 13 or 14 depending on your model) • see Troubleshooting, pages 17 through 19 Note:The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color. Thermocouple Pilot Burner Thermocouple Pilot Burner Figure 24 - Correct Pilot Flame Figure 25 - Incorrect Pilot Flame Pattern Pattern BURNER FLAME PATTERN BLUE FLAME MODELS Figure 26 shows a correct burner flame pattern. Figure 27 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height. WARNING: If yellow tipping occurs, your heater could produce increased levels of carbon monoxide. If burner flame pattern shows yellow tipping, proceed with the following instructions. NOTICE: Do not mistake orange flames with yellow tipping. Dust or other fine particles enter the heater and burn causing brief patches of orange flame. If burner flame pattern is incorrect, as shown in Figure 27 • turn heater off (see To Turn Off Gas to Appliance, pages 12 or 14 depending on your model) • see Troubleshooting, pages 17 through 19 1/2 GLASS HEIGHT Yellow Tipping 1/2 GLASS HEIGHT Figure 26 - Correct Burner Flame Pattern (Models GWN6 and GWP6 will be lower due to lower input rating) Figure 27 - Incorrect Burner Flame Pattern BURNER FLAME PATTERN INFRARED MODELS Figure 28 shows a correct burner flame pattern. Figure 29 shows an incorrect burner flame pattern. If burner flame pattern is incorrect, as shown in Figure 29 • turn heater off (see To Turn Off Gas to Appliance, page 13 or 14) • see Troubleshooting, pages 17 through 19 Figure 28 - Correct Burner Figure 29 - Incorrect Burner Flame Pattern Flame Pattern For more information, visit more information, visit 107902-01D 16 16 CLEANING AND MAINTENANCE ODS/Pilot and Burner Orifice Cleaning Burner Pilot Air Inlet Hole Cabinet CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet...

Эта инструкция также подходит к моделям:
Газовые нагреватели - GWN10 (3.17 mb)
Газовые нагреватели - GWN10T (3.17 mb)
Газовые нагреватели - GWN6 (3.17 mb)
Газовые нагреватели - GWP10 (3.17 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории