|
Фрагмент инструкции
Fuel Conversions Before making gas connections ensure that the appliance being installed is compatible with the available gas type. Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a qualified technician using Hearth & Home Technologies specifi ed and approved parts. 1. Converting to LP Gas Figure 6.2the wire clip. Pull off pilot hood and set aside. Do not remove MILLIVOT GENERATOR THERMOCOUPLE PILOT HOOD ALIGNMENT NOTCH NOTE: Gas conversions should only be performed by a qualified service person, and/or where required by state and local codes, licensed installer/service technician. In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter. Any damaged valve components should not be installed. If a valve or regulator has been dropped or appears to have been modified, the valve or regulator should not be installed. KIT CONTENTS: Replacement orifi ce; replacement pilot injector; valve regulator; and conversion label. TOOLS REQUIRED: #2 Phillips head screwdriver, slotted screwdriver or Torx TH20; 5/32 in. Allen wrench; 3/8 in. open end wrench. Remove 2 screws Figure 6.1 Remove top and front (if installed), glass, and logs (if installed). Remove burner by removing ONLY the two screws indicated. DO NOT remove the screws from the burner top. Lift the burner up and out of the firebox. 5/32 in. Allen wrench Figure 6.3 Use a 5/32 in. Allen wrench to remove the pilot injector. Replace pilot injector with the one supplied with the appliance (#35 for Propane, #62 for Natural Gas). Replace pilot hood, snapping into position. Figure 6.4 Remove main burner orifice using a 3/8 in. wrench. Be sure to align notch on left side of pilot hood, shown. Replace orifice with the proper size as indicated below for your gas type and venting. PROPANE NATURAL GAS #56 #49 Reinstall burner. August 1, 2008 Heat & Glo · Tiara Petite B · 7026-101K Page 25 2. Valve Regulator Replacement WARNING Fire Risk. Explosion Risk. • Disconnect any electrical cords and turn off gas supply to unit before proceeding if converting fuel on an appliance already fully installed. Remove upper and lower back shield. Loosen the set collars on the extension rods with the 3/32 in. Allen wrench. Remove the rods and adapter cap. A B C Mounting Screws Pressure Regulator Tower Diaphragm Figure 6.5 Turn control knob to the OFF position, ensure that gas supply to the valve has been turned off. Using a Torx TH20, or slotted screwdriver, remove the three pressure regulator mounting screws (A), pressure regulator tower (B), and diaphragm (C). E D F Rubber Gasket Screws Identification Label Figure 6.6 Ensure that the rubber gasket (D) is properly positioned and install the new HI/LO pressure regulator assembly to the valve using the new screws (E) supplied with the kit. Tighten screws securely. (Reference torque = 25 in./lb.) Install the enclosed identifi cation label (F) to the valve body where it can be seen. Fill out the conversion label and attach it to the valve cover. WARNING Fire Risk. Explosion Risk. Gas Leak Risk. • Rubber gasket must be seated properly on valve face. • Do no install a valve or regulator that has been dropped. WARNING Fire Risk. Explosion Risk. • If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. • The qualified service agency is responsible for the proper installation of this conversion kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit. Page 26 Heat & Glo · Tiara Petite B · 7026-101K August 1, 2008 B. Gas Pressures C. Gas Connection Proper input pressures required for optimum appliance performance, gas line sizing requirements need to be followed from NFPA51. NOTE: A listed (and Commonwealth of Massachusetts approved) 1/2 inch (13mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 inch (13mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. NOTE: Have the gas supply line installed in accordance with local building codes, if any. If not, follow ANSI Z223.1. Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fi tter.) WARNING Fire Risk. Explosion Hazard. High pressure will damage valve. • Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig. • Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig. Pressure requirements for appliance are shown in the table WARNING Verify inlet pressures. • High pressure may cause overfi re condition. • Low pressure ma...
Эта инструкция также подходит к моделям:Газовые нагреватели - TIARAP-BK (4.16 mb)
Газовые нагреватели - TIARAP-BR (4.16 mb)
Газовые нагреватели - TIARAP-CTO (4.16 mb)