Производитель: Empire Comfort Systems
Размер: 4.77 mb
Название файла:
|
Фрагмент инструкции
TO EXTEND VENT RUN, AN ADDITIONAL VENT EXTENSION KIT IS NECESSARY VENTING SUPPORT STRAPS (AS REQ’D) 35’ MAX CEILING ADJUSTABLE FIRESTOP/THIMBLE ASSEMBLY CLEARANCE TO COMBUSTIBLES REQUIRED FROM VENT PIPE ADJUSTABLE ROOF JACK ASSEMBLY STORM COLLAR DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) Figure 36 25613-0-0309 Page 25 Vertical Flex Termination Kit Item Number Item Description Repair Part No. Quantity Supplied 1 4”/7” Vertical Termination Cap MF100038 1 2 Roof Support Kit MF100503 1 3 2 Ply Alum Flex 4” Diameter by 6 ft. MF04ALA2F006 1 4 2 Ply Alum Flex 7” Diameter by 6 ft. MF07ALA2F006 1 5 4”/7” x 48” Rigid Pipe Assembly MF100554 1 6 Firestop Thimble Assembly MF100124 1 7 Roof Flashing (0/12 to 6/12) MF100091 1 8 7” Flex Adapter Collar with Gasket MF100524 1 9 7” Storm Collar MF100147 2 10 Spring Spacers MF100548 5 N/S Clamp 4” Diameter MF100330 2 N/S Clamp 7” Diameter MF100534 2 N/S #8 x 1/2” Self Drilling Screws N/A 20 N/S HT Silicone N/A 1 N/S #8 x 5/8” Self Drilling Screws N/A 10 DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) Page 26 25613-0-0309 CAUTION: Sharp edges, use protective gloves when installing. Tools Needed for Installation: Sheet metal snips 5/16” nut driver Phillips head screwdriver - #2 High temperature sealant or furnace cement rated for continuous use at 1,000oF minimum Measuring tape Parts Verification See parts list on page 28 to verify components included in this vent kit prior to installation. NOTE: If installing onto wood, lap, or vinyl siding, the vinyl siding kit should be used (sold separately, part number DV-822). The vinyl siding vent kit, DV-822, is available from Empire Comfort Systems, Inc. The depth is 3” (76 mm), which enables the vent cap to be extended away from vinyl siding or projections. The wall depth plus the additional 3” (76 mm) depth of the vinyl siding vent cap extension should not exceed a total depth of 13 3/4” (349 mm). If wall depth exceeds 13 3/4” (349 mm), extend system using 6 5/8” (168 mm) x 4” (102 mm) rigid venting (See Fireplace Instructions for approved lengths) See Figure 38. Installing Wall Thimble/Firestop Assembly 1. Fix fireplace to permanent location. If using rigid venting system, install up to the location where it will exit the building. 2. Cut hole in wall for wall thimble/firestop assembly into your combustible wall. See Figure 37. Note: On brick or block exterior wall a 7” (178 mm) diameter hole needs to be cut. Measure the total wall thickness to determine whether or not the extension thimble is to be used. If the combustible wall depth is over 5 3/8” (137 mm), then the extension thimble should be used. See Figure 37. 3. Install the wall thimble assembly through the framed opening so the firestop plate is on the interior wall. See Figure 37. Telescope section should extend all the way through the exterior wall. Attach with (4) 10 x 1” screws. 4. When placing the vent cap on an exterior wall covered with combustibles such as wood, lap, or vinyl siding, install the vinyl siding kit to the exterior wall sheathing. Figure 37 Figure 38 Cutting Vent Tubes This is the most important part of the installation. With the fireplace (and the rigid venting system if used) fixed to its permanent location, the 6 5/8” (168 mm) diameter air inlet tube and the 4” (102 mm) diameter flue outlet tube are to be marked and cut using the following procedure. 5. Attach the inlet tube to the outside mounting plate. Align tinnerman clips on the tabs of the air inlet tube to the holes on outside mounting plate, and fix with (2) #10 x 1/2” screws. 6. With the vinyl siding kit installed to wall (if necessary), insert the 6 5/8” (168 mm) diameter tube with outside mounting plate attached through hole in wall. Connect to collar on fireplace or rigid vent system. Measure between wall or vent cap extension and outside mounting plate (Figures 39 and 40). 11” 9” NOTE: SPACING FLANGE INSTALLED TO TOPSIDE INTERIOR WALL EXTENSION THIMBLE DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS X X = 13 3/4” MAX TOTALWALL THICKNESS (SUBTRACT 3” IF USING THE DV822 VINYL SIDING KIT) .” AIR SPACE CLEARANCE DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued) DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued) OUTSIDEWALLVINYLSIDINGKITDV822 7. Remove outside mounting plate with tube attached from wall. Mark and cut the extra length of the 6 5/8” (168 mm) diameter tube from the opposite end. Do not crimp or enlarge tube. OUTSIDE MOUNTING PLATE 8. Attach the 4” (102 mm) diameter flue outlet tube onto the rigid venting system or directly to fireplace. Ensure the 4” (102 mm) diameter flue outlet tube is placed as far as possible onto the rigid venting system. Mark the 4” (102 mm) diameter flue outlet tube 2 1/2” (64 mm) beyond the vinyl siding kit or wall. See Figure 39. Remove the 4” (102 mm) diameter flue MEASURE outlet tube from rigid venting system. When installing directly to fireplace, tape gasket needs to be used. 9. Mark or wrap tape completely around the tubes at the marked points ...
Эта инструкция также подходит к моделям:Газовые нагреватели - DVX36DP71(N,P)-1 (4.77 mb)
Газовые нагреватели - DVX36DP31(N,P)-1 (4.77 mb)
Газовые нагреватели - DVX36DP91(N,P)-1 (4.77 mb)
Газовые нагреватели - DVX42DP71(N,P)-1 (4.77 mb)