A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance • Do not touch any electrical switch; Do not use any phone in your building • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 1. Set REMOTE/OFF/ON switch to OFF. 2. Turn off all electric power to the appliance if service is to be performed (if applicable). 3. Open bottom louver assembly (if applicable). 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close bottom louver assembly (if applicable). 1. STOP! Read the safety information above on this label. 2. Set REMOTE/OFF/ON switch to "OFF". 3. Turn off all electric power to the appliance (if applicable). 4. Open bottom louver assembly (if applicable). 5. Push in gas control knob slightly and turn clockwise to "OFF". NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force. 6. Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step. 7. Find pilot - Follow metal tube from gas control. The pilot is located next to the burner, near the right side. 8. Turn gas control knob counterclockwise to "PILOT". 9. Push in control knob all the way and hold in. Repeatedly push the Piezo Ignitor Button until the pilot is lit. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob, and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9. • If knob does not pop up when released, STOP and IMMEDIATELY call a qualified service technician or gas supplier. • If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier. 10. Turn gas control knob counterclockwise to "ON". 11. Close bottom louver assembly (if applicable). 12. Turn on all electric power to the appliance (if applicable). 13. Set REMOTE/OFF/ON switch to desired setting. GAS CONTROL KNOB SHOWN IN "OFF" POSITION. THERMOCOUPLE (NATURAL) ELECTRODE PILOT THERMOPILE REMOTE OFF ON THERMOCOUPLE (LPG) GAS CONTROL KNOB SHOWN IN "OFF" POSITION. THERMOCOUPLE (NATURAL) ELECTRODE PILOT THERMOPILE REMOTE OFF ON THERMOCOUPLE (LPG) GAS CONTROL KNOB SHOWN IN "OFF" POSITION. THERMOCOUPLE (NATURAL) ELECTRODE PILOT THERMOPILE REMOTE OFF ON THERMOCOUPLE (LPG) VFDR(18,24,30)LB LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE PILOT FLAME CHARACTERISTICS Figure 18 shows a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down. VFDR (Series) PILOT Cleaning and Maintenance/Pilot Oxygen Depletion Sensor Pilot (Figure 20) When the pilot has a large yellow tip flame, clean the Oxygen Depletion Sensor as follows: 1. Clean the ODS pilot by loosening nut B from the pilot tubing. When this procedure is required, grasp nut A with an open end wrench. 2. Blow air pressure through the holes indicated by the arrows. This will blow out foreign materials such as dust, lint and spider webs. Tighten nut B also by grasping nut A. Figure 20 Correct Pilot Flame Pattern Figure 18 Incorrect Pilot Flame Pattern Figure 19 If pilot flame pattern is incorrect, as shown in Figure 19 • See Troubleshooting, page 19. 21565-3-0906 Page 17 CLEANING AND SERVICING Annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting. TURN OFF HEATER AND ALLOW TO COOL BEFORE CLEANING. Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceramic fibers. If skin becomes irritated, wash gently with soap and water...

Эта инструкция также подходит к моделям:
Газовые нагреватели - VFDR24LB (2.28 mb)
Газовые нагреватели - VFDR18LB (2.28 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории