Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации England's Stove Works, модель 25PAH

Производитель: England's Stove Works
Размер: 1.48 mb
Название файла: 25-PAH.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


CALL TECHNICAL SUPPORT WITH QUESTIONS. OUTSIDEAIRHOOK.UPOUTSIDEAIRHOOK.UP . The use of outside combustion air is mandatory on this pellet stove. . The outside air connection pipe protrudes from the lower rear center of the stove; use the included outside air kit to attach your stove to outside combustion air. Instructions and all the parts needed to make the outside air connection to your pellet stove are included with the outside air kit. . If it is not feasible to use the included outside air hookup kit in your stove installation, other materials may be used, provided the following rules are followed: o The pipe used for outside air hookup must be metal, with a minimum thickness of .0209in. (25 gauge mild steel) or greater and an inside diameter of approximately 2.0 in. o All pipe joints and connections should be sealed with pipe clamps or other mechanical means, to insure a leak free outside air connection. o Long runs of pipe and excessive elbows for outside air should be avoided. Due to frictional resistance in pipe, any excessive outside air piping can result in poor stove performance. o A screen or other protection device must be fitted over the outside air termination point to prevent rain, debris and nuisance animals from entering the piping system. o Increase the outside air pipe size to 3.0 in. diameter pipe if the outside air connection is more than 6 ft. in length, more than two (2) elbows are used or if the stove is installed in a basement. . The outside air connection system should be inspected at least annually to be certain it is free from blockage. Caution NEVER draw outside combustion air from: . Wall, floor or ceiling cavity. . Enclosed space such as an attic, garage or crawl space. 15 IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED. ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS. FLOORPROTECTIONFLOORPROTECTION . This pellet stove requires a non.combustible floor protector if the stove is to be installed on a combustible floor. If the floor the stove is to be installed on is already non.combustible (i.e. a concrete floor in a basement) and has an R value equal to or higher than .2, no floor protection is needed (although a decorative floor protector can still be used for aesthetic reasons). . Prefabricated floor protectors which are UL listed (ULC if Canada) or equivalent can be purchased or a floor protector can be built from standard materials; two sheets of .5” thick cement board covered with ceramic tile would be a suitable floor protector which meets the .2 R.value requirement. . When using any floor protector, consider that this stove is not only heavy but will induce heating and cooling cycles on the floor protector which can damage tile and loosen mortar and grout joints. A hearth rug is NOT an approved substitute for a proper hearth pad. . For the US: The floor protector must extend at least 6 in. (152.4 mm) from the front & sides and 4 in. (101.6 mm) from the rear. . For Canada: The floor protector must extend at least 18.0 in. (457.2 mm) from the front of the unit, 8.0 in. (203.2 mm) from the sides of the unit and 4.0 in. (101.6 mm) from the rear. US:6.0in. Canada:8.0in. US:6.0in. Canada:8.0in. US:4.0in. Canada:4.0in. US:6.0in. Canada:18.0in. . In Canada, it is required that the non.combustible floor protector is underneath and extends 2 in. (50.8 mm.) on either side of any horizontal venting runs AND/OR is directly underneath any vertical venting pipe. 16 IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED. ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS. DAILYOPERATIONDAILYOPERATION Getting Started . Check to see that the hopper is clean and free from foreign materials. Be sure to connect this unit to a working outlet; we recommend using a surge protector to help protect the electronic components from damage. . BEFORE your first fire, dry run your unit (no pellet fuel in the hopper) for twenty minutes; pressing the “ON” button with the unit plugged in will initiate the dry run. o Once the “ON” button is pressed, you should immediately hear the exhaust blower start and operate continuously. o After about three to five minutes, look for the red glow of the igniter in the igniter port of the burn pot to be certain it is operating normally. o Hold the hopper lid switch (See “Illustrated Parts Diagram” pg. 38) down with your finger and check to see that the auger is turning. Release the hopper lid switch and be certain that the auger stops turning. DO NOT PUT YOUR FINGERS IN THE...

Эта инструкция также подходит к моделям:
Газовые нагреватели - 55TRPAH (1.48 mb)
Газовые нагреватели - 55SHPAH (1.48 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории