Войти:
Оценок - 4, средний балл: 4.3 ( )

Инструкция по эксплуатации Modine Manufacturing, модель PAE

Производитель: Modine Manufacturing
Размер: 2.95 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Air deflectors on, 40° and 90° discharge nozzles set perpendicular to the face of the air discharge opening. On 5-way nozzles all air deflectors set perpendicular to floor. Static pressure measured at 0.1" W.C. for 90° nozzle, 0.2" W.C. for 40° downward and 5-way nozzle, and 0.3" W.C. for 40° splitter nozzle. Outlet velocities are approximately 1750 FPM for the 40° nozzles, 1000 FPM for the 90° nozzle and 1300 FPM for 5-way. For motor size, drive and blower rpm refer to pages 18 and 19. Mounting height measured from bottom of unit. A choice of four air discharge nozzles accommodate various heat throw patterns illustrated. Equipped with adjustable louver blades, nozzles are fabricated from galvanized steel and are offered either unpainted or painted to match the finish of the blower unit heaters. Nozzles are flanged for easy attachment over the air discharge opening of the blower unit heater. Heater Parts from ACF Greenhouses 15 DIMENSIONAL DATA Dimensions (in inches) A C B /4" 3 D B A /4" 3 C D B C D A /4" 3 40° Downward Nozzles 90° Downward Nozzles B A /4" 3 C D 40° Splitter Nozzles 5-Way Nozzle A 14-13/16 16-13/16 18-9/16 18-9/16 21-1/16 23-3/16 23-3/16 26-3/16 26-3/16 31-1/8 31-1/8 37-1/2 B 16 16 20 20 20 24 24 24 24 24 24 24 C 24 22 26 26 25 30 30 30 30 36 36 36 D 4 3 4 4 4 4 4 6 6 11 11 11 A 14-13/16 16-13/16 18-9/16 18-9/16 21-1/16 23-3/16 23-3/16 26-3/16 26-3/16 31-1/8 31-1/8 37-1/2 B 16 16 20 20 20 24 24 24 24 24 24 24 C 15 17 22 22 23 29 29 30 30 34 34 34 D 6 6 8 8 8 10 10 10 10 14 14 14 A – – 18-9/16 18-9/16 21-1/16 23-3/16 23-3/16 26-3/16 26-3/16 31-1/8 31-1/8 37-1/2 B – – 20 20 20 24 24 24 24 24 24 24 C – – 34 34 33 39 39 40 40 46 46 47 D – – 10 10 11 12 12 14 14 19 19 20 A 14-13/16 16-13/16 18-9/16 18-9/16 21 23-3/16 23-3/16 26-3/16 26-3/16 31-1/8 31-1/8 37-1/2 B 16 16 20 20 20 24 24 24 24 24 24 24 C 20-3/4 22-3/4 24-1/2 24-1/2 27 29 29 32 32 37 37 43-1/2 D 11 12 13 13 14 15 15 16 16 18 18 18 Model Number 40° Downward Nozzle 90° Vertical Nozzle 40° Splitter Nozzle 5-Way Nozzle Nozzle Type Dimension Symbol BAE-50 BAE-75 BAE-100 BAE-125 BAE-145 BAE-175 BAE-200 BAE-225 BAE-250 BAE-300 BAE-350 BAE-400 Heater Parts from ACF Greenhouses Model PAE 50 PAE 75 PAE 100 PAE 125 PAE 145 PAE 175 PAE 200 PAE 225 PAE 250 PAE 300 PAE 350 PAE 400 S S S S S S S S S S S S 8' 14 23 23 34 46 32 44 44 65 57 68 74 10' 12 21 20 30 42 29 39 39 58 51 60 66 12' 11 19 19 27 38 26 36 36 53 47 55 60 14' – 17 17 25 35 25 33 33 50 43 51 56 16' – 16 16 23 33 23 31 31 46 41 48 52 18' – – – 22 31 22 29 29 44 38 45 49 20' – – – 21 29 21 28 28 41 36 43 47 22' – – – – – – 27 26 40 35 41 45 24' – – – – – – 25 25 38 33 39 43 26' – – – – – – – – 36 32 38 41 28' – – – – – – – – 35 31 36 40 30' – – – – – – – – 34 30 35 38 32' – – – – – – – – – – 34 37 34' – – – – – – – – – – – 36 16 PERFORMANCE DATA – HOODS Performance Data — 30°, 60° and 90° Downward Deflector Hoods — Propeller Models MOUNTING HEIGHT X Y Y Z Z X 60° NOZZLE 30° NOZZLE 60° 30° 30° DOWNTURN NOZZLE 60° DOWNTURN NOZZLE NOTE: X = FEED FROM HEATER TO START OF FLOOR COVERAGE. Y = FEET TO END OF FLOOR COVERAGE. Z = FEET TO END OF THROW. 30° HOOD 60° HOOD THROW-FLOOR COVERAGE Model PAE 50 PAE 75 PAE 100 PAE 125 PAE 145 PAE 175 PAE 200 PAE 225 PAE 250 PAE 300 PAE 350 PAE 400 X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z 8' 6 14 19 10 24 32 9 22 31 14 30 41 18 38 52 13 28 39 17 36 49 17 36 49 23 48 65 20 42 57 23 48 65 24 50 68 10' – 9 21 30 8 19 27 12 29 39 17 37 51 11 26 36 15 35 47 15 34 47 22 47 64 19 41 56 22 47 64 23 49 67 12' – 6 17 24 5 13 19 11 26 36 16 36 49 10 24 33 14 33 45 14 33 45 21 46 63 18 40 54 21 46 62 22 48 65 14' – – – 9 23 32 14 34 47 7 19 27 13 31 42 12 30 42 20 44 61 16 38 52 20 44 61 21 47 64 16' – – – – 12 31 43 – 10 27 38 10 27 37 18 42 58 15 36 49 18 42 58 19 45 62 18' – – – – – – 7 20 29 7 20 29 17 40 56 13 33 45 16 40 55 18 43 59 20' – – – – – – – – 15 37 52 10 27 38 15 37 51 16 40 55 22' – – – – – – – – 12 32 45 – 12 32 45 14 36 51 24' – – – – – – – – – – – 9 27 39 Mounting Height to Bottom of Heater 30° Downward Hood For Propeller Units % Mounting Height to Bottom of Heater 90° Downward Hood For Propeller Units % % Data Based on units fired at full rated input with an entering air temperature of 60°-80°F. Maximum mounting heights higher versus units without outlet devices. Model PAE 50 PAE 75 PAE 100 PAE 125 PAE 145 PAE 175 PAE 200 PAE 225 PAE 250 PAE 300 PAE 350 PAE 400 X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z 8' 0 13 18 0 24 33 0 22 30 0 32 43 0 41 56 0 30 40 0 38 52 0 38 51 0 51 70 0 45 61 0 51 69 0 53 73 10' – 0 21 29 0 18 25 0 29 40 0 39 54 0 27 37 0 36 49 0 36 49 0 50 68 0 43 59 0 49 68 0 52 71 12' – 0 15 21 0 9 13 0 26 36 0 37 51 0 23 32 0 34 46 0 33 45 0 48 66 0 41 57 0 48 65 0 50 69 14' – – – 0 21 29 0 34 47 0 16 23 0 30 41 0 30 41 0 46 63 0 39 53 0 46 62 0 48 66 16' – – – 0 15 22 0 30 41 – 0 25 35 0 25 34 0 43 59 0 35 49 0 43 59 0 46 63 18' – – – – 0 24 33 – 0 14 19 0 14 19 0 40 55 0 ...

Эта инструкция также подходит к моделям:
Газовые нагреватели - BAE (2.95 mb)
Газовые нагреватели - BAE (2.95 mb)
Газовые нагреватели - BAE (2.95 mb)
Газовые нагреватели - BAE (2.95 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории