Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Coleman, модель 5075 Series

Производитель: Coleman
Размер: 660.97 kb
Название файла: 56a1c93b-5695-6bb4-65b9-2561f5b25474.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


. . . . . . . . . . . . . . . 12, 13 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Technical and Repair Service . . . . . . . . . . . . . . . . . . . . . . 44 PRODUCT IDENTIFICATION Piezo Ignitor Button Top Shell POL Fitting Propane Hose/Regulator Assembly Figure 1 - 40,000 BTU/Hr. Model Automatic Valve Button Burner Valve Knob Inlet Connection Figure 2 - 50,000 to 80,000 BTU/Hr. Model 4 Product Identification 1. Remove all packing items applied to heater for shipment. Keep plastic cover caps (attached to inlet connection and hose/regulator assembly) for storage. 2. Remove all items from carton. 3. Check all items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater. The Fuel System: The hose/regulator assembly attaches to the propane gas supply. The propane gas moves through the thermoelectric valve and out the nozzle. The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air. The Ignition System: The piezo spark ignitor (Model 5070A) or Electronic Module (Model 5075A) sends voltage to the electrode. The spark at the electrode ignites the fuel air mixture. The Safety Control System: This system causes the heater to shut down if the heater overheats for any reason including loss of electric power. (The fan will continue to operate if electric power is not lost.) UNPACKING THEORY OF OPERATION Fan Motor Cool Air In (Back) Power Cord Hose/Regulator AssemblyElectrode Clean Heated Air Out (Front) Combustion Chamber Air For Heating Combustion Air Fuel Ignitor Cross Section Operational View (5070A Model Shown) Propane gas and propane tank(s) are to be furnished by the user. Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58. Your local library or fire department will have this booklet. The amount of propane gas ready for use from propane tanks varies. Two factors decide this amount: 1. The amount of propane gas in tank(s). 2. The temperature of tank(s) PROPANE SUPPLY ENGLISH Propane Supply Information continues on next page 5 PROPANE SUPPLY Continued PROPANE SUPPLY Continued VENTILATION PREPARATION The chart below shows the minimum number of 20-pound or larger tanks needed to run these heaters at the temperature indicated for at least 10 hours. Do not operate them with tanks smaller than indicated. Reduced performance will result. NUMBER OF TANKS REQUIRED Average Temperature (°F) At Tank Location 32° 20° 10° 0° -10° (0°C) (-7°C) (-12°C) (-18°C) (-23°C) 5070A751 (40,000 BTU/Hr.) 1-20# 1-40# 1-100# 2-100# 3-100# 5075A751 (80,000 BTU/Hr.) 1-100# 2-100# 2-100# 3-100# 3-100# Less gas is vaporized at lower temperatures. You may need two or more 100-pound tanks or one larger tank in colder weather. Your local propane gas dealer will help you select the proper supply system. WARNING Provide at least a 3-square-foot (0.3 m2) opening of fresh, outside air while running heater. If proper outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper outside air ventilation before running heater. WARNING Test all gas piping and connections for leaks after preparation or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks before using product. 1. Determine propane supply needed. (See Propane Supply). 2. Connect hose to inlet connector. Tighten firmly in clockwise direction using 9/16" wrench. Hose and Inlet Connector Tighten with Wrench Continued 6 3. Connect POL fitting on hose/regulator assembly to propane tank(s). Turn POL fitting counterclockwise into threads on tank. Tighten firmly. IMPORTANT: Tighten regulator with vent pointing down. Pointing vent down protects regulator from weather damage. PREPARATION Continued Regulator With Vent Pointing Down 4. Open valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve on propane tank will stop gas flow. If this happens, close propane valve and open again slowly. 5. Check all connections for leaks. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak that must be corrected before using heater. 6. Close propane supply valve. WARNING OPERATION Review and understand the warnings in the General Safety Information Section. They are needed to safely operate this heater. Follow all local ordinances or codes when using this heater. To Start Heater 1. Follow all preparation, ventilation, and safety information. 2. Locate heater on stable and level surface...

Эта инструкция также подходит к моделям:
Газовые нагреватели - 5070 Series (660.97 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории