Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Carrier, модель COMFORTLINK P5030-100

Производитель: Carrier
Размер: 555.2 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified installer, service agency or the gas supplier. DANGER 1. Do not turn off the electrical power to unit withoutfirst turning off the gas supply. 2. Before attempting to start the gas heating section, familiarize yourself with all the procedures that mustbe followed. 3. Never attempt to manually light the burners on theunit with a match, lighter, or any other flame. If theelectric sparking device fails to light the burners, referto the shutdown procedures, then call your dealer assoon as possible. If you do not follow these instructions exactly, a fire orexplosion may result, causing property damage, injury, orloss of life. WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency, or the gas supplier. WARNING Before performing recommended maintenance, be sure main power switch to unit is turned off and lockout tag isinstalled. Electrical shock could cause personal injury. Your combination heating/cooling rooftop unit is equippedwith an automatic direct spark ignition system and induced- draft power combustion blower. WARNING Burners will light automatically. Do not attempt to light byhand; personal injury may result. See Fig. 1 for location of gas valve(s). Refer to Fig. 2 whileproceeding with the following steps. 1. Turn off the unit demand for cooling or heating by usingthe scrolling marquee. The scrolling marquee is located inthe control box at the compressor end of the unit. ESCAPE a. Push the key unit a blank display screen is shown. b. Push the key until the SERVICE TEST LED is lit. c. Push the ENTER key. The display will show STOP. d. Push the ENTER key again. The NO/YES display will flash. e. Push the or key to toggle the display to YES and then push ENTER . The unit will be locked off from heating, cooling or any operation. The controls will still function and the display willstill operate. 2. Close the field-installed manual gas shutoff valve. 3. Turn off the electrical power to the unit using the optionaldisconnect or the field-installed disconnect and lock off using proper lockout and tag-out procedures. 4. Open the burner section hinged access door. 5. Move the switch on the gas valves to the OFF position and wait 5 minutes. NOTE: If this is the first installation of the unit, the gas flue hoods must be installed before operating unit. These must be installed for the unit to run properly. 6. Move the switch on the gas valves to the ON position. 7. Close the burner section hinged access door. 8. Turn on the electrical supply to the units. 9. Open the field-installed manual gas valve. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480054-01 Printed in U.S.A. Form 48P-1SO Pg 1 4-09 Replaces: New 2 10. Using the scrolling marquee, enable the unit to run using the following procedure: a. Push the key unit a blank display screen is shown. b. Push the key until the SERVICE TEST LED is lit. c. Push the key. The display will show STOP. d. Push the key again. The NO/YES display will flash. e. Push the or key to toggle the display to NO and then push . The unit will return to normal operation and exit SERVICE TEST mode. 11. To test the operation of the gas section, use the scrolling marquee Service Test routine to energize the gas outputs and to turn on the gas. Refer to the unit Controls, Start- Up, Operation, Service and Troubleshooting literature for more information. 12. For normal operation, make sure that units with a conventional thermostat are set to heating control temperature. On VAV (variable air volume) and constant volume units with a space temperature sensor, make sure that the set points are at the normal heat set points. WARNING If the main burners fail to light or the blower fails to start, shut down gas heating section and call your dealer for service. Failure to follow these requirements could result in serious personal injury. ESCAPE ENTER ENTER ENTER LIMIT SWITCH NO. 1 SECTION 1 SECTION 2 LIMIT SWITCH NO. 2 GAS VALVE GAS VALVE FLUE OUTLET FLUE OUTLET GAS VALVE FLUE OUTLET LIMI...

Эта инструкция также подходит к моделям:
Газовые нагреватели - COMFORTLINK 48P2 (555.2 kb)
Газовые нагреватели - COMFORTLINK P3 (555.2 kb)
Газовые нагреватели - COMFORTLINK P4 (555.2 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории