Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Carrier, модель 58GSC

Производитель: Carrier
Размер: 295.63 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The kit can be used to convert propane gas 100% shutoff IID controls to natural 100% shutoff IID. It is designed for use in furnaces with 30,000- thru 100,000-Btuh nominal output capacity. These furnaces are to be installed only within California. NOTE: The definition of 100% shutoff refers to automatic shutoff of the pilot and main burner gas when the ignition source is not proven. NOTE: Read the entire instructions before starting the installation. There are additional parts shipped in the kit. When the installation is complete, discard the unused parts. A CAUTION Do not use this kit to convert 58DR and 58GS units to natural gas applications. A WARNING Improper installation, adjustment, alteration, service, maintenance, or use can cause carbon monoxide poisoning, explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, local gas supplier, or your Distributor or Branch for information or assistance. The qualified installer or agency must use only factory-authorized kits or accessories when modifying this product. New NOx burners must be installed along with this kit. The burners are not supplied with the kit. Order the required number of burners for the furnace being converted. Order burner P/N 309472-751. This kit contains the following items: Table 1 —Kit Contents DESCRIPTION P/N QTY Natural Conversion Kit—Regulator Spring for White-Rodgers 36E Gas Valve (Silver, 10 Turns) EF39ZW037 1 Natural Regulator Spring for BDP 646A Gas Valve (Silver, 3-Ins. Long) 301248-101 1 Pilot Orifice (Silver, 1/2-In. Long, 0.018-In. Orifice Diameter) 307123-701 1 Main Burner Orifice No. 45 LH32DB205 6 Gas Control Conversion Label 310148-302 1 Conversion Responsibility Label 310167-312 1 Conversion Rating Plate 310168-312 1 installation Instructions 58D, G-2SI 1 A WARNING This conversion kit is to be installed by a Carrier factory-authorized Dealer, Distributor, or other qualified agency in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. A failure to follow instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for this conversion. A. Installation of Pilot Orifice 1. Turn off gas and electric supplies to furnace. 2. Remove control access door. 3. Disconnect pilot gas tube from gas valve. 4. Unplug electrode wire from spark generator. 5. Remove pilot assembly from burner and furnace. 6. Using backup wrench, remove gas supply tube from pilot. 7. Remove and discard propane gas pilot orifice (silver, 5/8-in. long, 0.012-in. diameter orifice, knurlj gas supply opening of pilot. SECONDARY AIR SHIELD MANIFOLD SUPPORT BRACKET RETAINING SCREWS (2) EACH SIDE MANIFOLD UNIT RATING PLATE CONVERSION RATING PLATE CONTROL COMPARTMENT SHELF -BURNER LOCATING PIN A80129 Fig. 1—Gas Controls Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book| 1 I 4 PC 101 Catalog No. 565-817 Printed in U.S.A. Form 58D,G-2SI Pg 1 11-88 Replaces: 58SSB-4SI Tab 16a 18a 8. Install new natural gas pilot orifice (silver, 1/2-in. long, 0.018-in. orifice diameter). 9. Reinstall pilot gas supply tube on pilot. When tightening pilot tube, use backup wrench and turn pilot so that it will be on the same angle as before. Do not reinstall pilot at this time. B. Installation of Main Burner Orifices 1. Remove secondary air shield. 2. Remove main burners from manifold. 3. Remove and discard No. 55 (or field-installed per local application) orifices from manifold. 4. Install No. 45 main burner orifices provided in kit. Finger-tighten orifices at least one full turn so as not to cross-thread, then tighten with wrench. There are enough orifices in each kit for the largest furnace. Discard extra orifices. The full input rating with No. 45 main burner natural gas orifices is approved for altitudes up to 2000 ft. The input rating for altitudes above 2000 ft must be reduced by 4% for each 1000 ft above sea level. Consult the current edition of the National Fuel Gas Code NFPA No. 54/ANSI Z223.1, Part 8.1 and Appendix F Table F-4, for input adjustment for high altitude. 5. Install new burners with NOx reduction screens on manifold. See Figs. 2 and 3 for proper orientation of burners and pilot. 6. Reinstall pilot assembly. 7. Reconnect pilot supply tube to gas valve. 8. Reconnect electrode wire to spark generator. 9. Reinstall secondary air shield. C. Conversion of Gas Valve and Inlet Gas Pressure Check 1. Remove regulator seal cap. See Fig. 4 for BDP 646A or Fig. 5 for White-Rodgers 36E Gas Valve. 2. Remove adjustment screw and propane gas regulator spring (red for 646A and white for 36E). 3. Install proper natural gas regulator spring (silver) provided in kit, in proper gas valve. See Table 1. 4...

Эта инструкция также подходит к моделям:
Газовые нагреватели - 58DRC (295.63 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории