Войти:
Оценок - 3, средний балл: 3.3 ( )

Инструкция по эксплуатации Desa Tech, модель CBP20

Производитель: Desa Tech
Размер: 1.65 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Keep this manual for reference. It is your guide to safe and proper operation of this heater. WARNING: Any change to this heater or its controls can be dangerous. WARNING: Do not use any accessory not approved for use with this heater. Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater. Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching. Carefully supervise young children when they are in the same room with heater. Make sure grill guard is in place before running heater. Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. For more information, visit more information, visit 107882-01E SAFETY INFORMATION LOCAL CODES PRODUCT IDENTIFICATION UNPACKING PRODUCT FEATURES 3 SAFETY INFORMATION 3. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrical switch; do not use any phone in your building • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions • if you cannot reach your gas supplier, call the fire department 4. This heater shall not be installed in a bedroom or bathroom. 5. This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. 6. Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion. 7. If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced. 8. Do not run heater • where flammable liquids or vapors are used or stored • under dusty conditions 9. Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. 10. Turn off and let cool before servicing. Only a qualified service person should service and repair heater. 11. Operating heater above elevations of 4,500 feet could cause pilot outage. 12. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity. 13. Provide adequate clearances around air openings. LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code, ANSI Z223.1/NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 PRODUCT IDENTIFICATION Control Knob & Ignitor Button (not seen from this view) Heater CabinetFront Glass Panel Grill Guard Panel Figure 1 - Vent-Free Gas Heater UNPACKING 1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipment. 3. Check heater for any shipping damage. If heater is damaged, promptly return to dealer where you bought heater. PRODUCT FEATURES SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater. THERMOSTATIC HEAT CONTROL Thermostat models have a thermostat sensing bulb and a control valve. This results in the greatest heater comfort. This can also result in lower gas bills. For more information, visit more information, visit 107882-01E 4 4 AIR FOR COMBUSTION AND VENTILATION Providing Adequate Ventilation AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home. Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air ...

Эта инструкция также подходит к моделям:
Газовые нагреватели - CBN20 (1.65 mb)
Газовые нагреватели - CBN20T (1.65 mb)
Газовые нагреватели - CBN30T (1.65 mb)
Газовые нагреватели - CBP20T (1.65 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории