Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Desa, модель FB-60BA

Производитель: Desa
Размер: 477.02 kb
Название файла: 369eca0c-1ead-1be4-e17d-2c463327ae43.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


to 14" W.C. Pressure) 3" Min. Propane/LP Supply Tank Vent Pointing Down External Regulator 4. If installing bottom mounting screw into hollow or solid wall, install wall anchor. Follow steps 1 through 4 under Attach- ing To Wall Anchor Method, page 8. If installing bottom mounting screw into wall stud, drill holes at marked loca- tions using 9/64" drill bit. 5. Replace heater onto mounting bracket. 6. Place spacer between bottom mount- ing hole and wall anchor or drilled hole. 7. Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole. 8. Tighten screw until heater is firmly secured to wall. Do not over tighten.Note:Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks. (see page 10). WARNING: This appliance re- quires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator. Continued 107299 9 PROPANE/LP GAS HEATER INSTALLATION Continued CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections for leaks after installation or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. CAUTION: Make sure external regulator has been installed between propane/LP supply and heater. See guidelines underConnecting to Gas Supply, page 9. Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 15). 2. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve. 3. Check all joints from propane/LP supply tank to equipment shutoff valve (see Figure 16). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once. Equipment Shutoff Valve Open O S Closed Figure 15 - Equipment Shutoff Valve Figure 16 - Checking Gas Joints Propane/LP Supply Tank Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 15). 2. Open propane/LP supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Figure 16). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, page 11 for non-thermostat models or pages 12 and 13 for thermostat model). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas To Appliance, page 11 for non-thermostat models or page 12 for thermostat model). 8. Replace front panel. Control Valve Location Equipment Shutoff Valve 10 107299 OWNER’S MANUAL OPERATING HEATER NON-THERMOSTAT MODELS FB-10BA AND FB-60BA FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. LIGHTING INSTRUCTIONS 1. STOP! Read the safety information in column 1. 2. Make sure equipment shutoff valve is fully open...

Эта инструкция также подходит к моделям:
Газовые нагреватели - FBS-10BB (477.02 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории